Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1K2310 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 500.

ABB Installation Products 15PCJ1K2310 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786093816


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 15PCJ1K2310 is a 15kV power cable joint designed for medium-voltage distribution systems. This joint accommodates copper conductors with insulation diameters between 1.090 inch and 1.310 inch, specifically rated for 500 kcmil solid conductors. The single-piece housing simplifies installation by eliminating multiple assembly steps, reducing labor time and potential error points. This joint is engineered for use in underground and aerial medium-voltage circuits where reliable, long-term insulation and conductor continuity are critical. It meets industry standards for 15kV class systems, ensuring compatibility with existing infrastructure. The housing material provides environmental resistance against moisture, UV exposure, and mechanical stress, extending service life in outdoor and buried applications. Typical installations include utility substations, industrial power distribution, commercial facilities, and renewable energy projects where medium-voltage cable joints are required for circuit extensions or repairs. The joint’s design supports hot-line installation when used with appropriate tools and procedures, minimizing downtime during maintenance. ABB’s engineering ensures consistent dielectric performance and mechanical integrity across the specified conductor and insulation range.
  • 15kV rated medium-voltage cable joint
  • Single-piece housing for simplified installation
  • Accommodates 1.090" to 1.310" insulation diameter
  • Designed for 500 kcmil solid copper conductors
  • Suitable for underground and aerial applications

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
1.090 inch to 1.310 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.5000 L
Package Weight (Metric)
1.1340 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.

15PCJ2J1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Solid 350.

28PCJ1K1290

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cold-Shrinkable Jacket Seal Included.

35PCJ1P1380-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 500.

15PCJ1J2330

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ2L1300-J1270

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1H2250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2M1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

15PCJ2L1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

What types of cable splicing can PCJ joints perform?

PCJ power cable joints can perform straight splicing of two similar cables or transition splicing of different cable sizes.

What pull force can the pin-and-socket interlock withstand?

The pin-and-socket interlock in the PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What type of connector is included for aluminum conductors?

Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ joints meet?

The shield design meets the IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What conductor materials are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors. They accommodate a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

PCJ power cable joints come in Style 1 with a single-piece housing for straight splicing, and Style 2 with universal housing and separate cable adapters for transition splicing.

Where can Elastimold PCJ power cable joints be installed?

These joints can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, fully submersible splice.

How to Install a Single Core Cable Joint (15PCJ1K2310)

This guide provides step-by-step instructions for the permanent installation of a fully screened, submersible single core straight joint for extruded solid dielectric cables.

Estimated time: 1h 30m

Tools needed:

Cable stripping tools, Knife or utility blade, Wire brush, Crimp tool, Cleaning solvent, Clean cloth, Soldering iron or constant force spring tool, Heat gun, Sanding tool or sandpaper

Supplies needed:

Joint Housing (15PCJ1K2310), PVC tape (multiple colors), Conductor compression connector, Lubricant, Flat copper braid, Constant force spring (optional), Mastic tape, Heat shrink tubing

  1. Perform Safety Checks and Prepare Workspace

    Before starting, ensure all apparatus is de-energized. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, rating, and compatibility. Check package contents for completeness. Have all required tools at hand and maintain cleanliness throughout the procedure. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing.

  2. Prepare Cables by Removing Jacket and Metallic Shield

    Train the cables into their final position and square cut, leaving approximately 5mm between cables. Store the heat shrink tubing, which is supplied with the joint, onto either cable. Remove the outer jackets of both cables to the dimensions specified in the provided table (dimension 'A'). Carefully remove the cable metallic tape screen for the distance shown (dimension 'B') and secure the ends with PVC tape. Ensure the PVC tape is only on the copper tape and does not overlap onto the non-metallic screen.

  3. Remove Non-Metallic Screen and Bevel Insulation

    WARNING: DO NOT NICK, CUT, OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen (semi-conductive shield) from both cables to the point specified (dimension 'D'). Bevel the edge of Cable 1's insulation. Cut the insulation to the conductor to dimension 'E' from the end of both cables, but DO NOT remove the insulation at this stage. Install a PVC tape marker on Cable 2 to dimension 'B' to locate the splice later.

  4. Prepare Cable 1 and Temporarily Store Joint Housing

    Beginning at the jacket and extending 10mm beyond the end of the metallic screen, apply one layer (half-lapped) of PVC tape over the metallic screen on Cable 1. WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing. Install a different color PVC tape marker on Cable 1 to dimension 'B' to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and the PVC taped portion of the cable metallic tape screen on Cable 1. Store the joint housing onto Cable 1, sliding it up to the jacket. DO NOT store the splice housing on the exposed metallic tape shield.

  5. Remove Remaining Cable Insulation

    Remove the remaining cable insulation from both cables to dimension 'E', exposing the conductor. WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  6. Install and Crimp the Conductor Splice Connector

    Wire brush the exposed conductors of both cables to ensure good contact. Immediately insert both conductors into the conductor splice, ensuring they are fully seated. DO NOT CRIMP at this point. Check the distance between the insulations; if it exceeds the 'Before' dimension specified in the table, DO NOT PROCEED and re-evaluate the assembly. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs from the crimped splice. Ensure all metal chips or filings are removed from the splice joint assembly area. Wipe off any excess inhibitor. Re-check the distance between cable insulations; if it exceeds the 'After' dimension, DO NOT PROCEED and review the instructions.

  7. Clean and Lubricate Core Surfaces

    WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces thoroughly using cleaning solvent and a clean cloth. Always wipe towards the screen end to prevent contamination from spreading. Lubricate the cable insulation surfaces using the lubricant supplied with the joint. Always wipe towards the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.

  8. Slide and Position the Joint Housing

    Carefully slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker on each side. The distance 'X' should be equal on both sides of the joint housing, indicating proper centering. Remove the PVC tape applied in Step 4 to expose 25mm of the copper tape shield on each side.

  9. Restore Metallic Screen with Copper Braid

    Wrap flat copper braid around each side of the joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen. This attachment can be done either by soldering or by using a constant force spring, ensuring a secure and continuous electrical connection.

  10. Restore Outer Jacket and Complete Sealing

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm on each side of the joint. Heat both sanded areas for approximately 15 seconds to prepare the surface. WARNING: DO NOT BURN CABLES during this heating process. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tubing (stored in Step 2) over the center of the assembly and begin shrinking it. Start shrinking from the center of the heat shrink and work outwards towards the ends, ensuring a tight and sealed outer jacket restoration.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.