ABB Installation Products 15PCJ1H2290 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786665716
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Single-piece housing for simplified installation and alignment
- Accommodates cable insulation diameters from 0.850" to 1.050"
- 350 kcmil solid copper conductor for reliable electrical continuity
- Compatible with XLPE and EPR insulated cables
- Meets ANSI/IEEE C119.1 standards for medium-voltage cable accessories
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.8000 L |
Package Weight (Metric) | 0.8170 kg |

15PCJ1G2300
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.
25PCJ1M1330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15PCJ2J1270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ2G1230-F1230
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1G2250
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
25PCJ1G1210
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
35PCJ1P1400
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15PCJ2J2280-J2270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.Frequently Asked Questions
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.
What are Elastimold PCJ power cable joints used for?
They are used for straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil.
Where can PCJ power cable joints be installed?
They can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, fully submersible splice.
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What conductor types and sizes are compatible?
They can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.
What are the two styles of PCJ power cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
What safety standards do PCJ joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
What type of connector is included for aluminum conductors?
Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.
How to Install a 15PCJ1H2290 Single Core Cable Joint
A comprehensive guide for the safe and correct installation of the 15PCJ1H2290 single core, fully screened, submersible cable joint for extruded solid dielectric (XLPE or EPR) cables.
Estimated time: 2h
Tools needed:
Cable stripping tools, Measuring tape or ruler, Wire brush, Crimping tool (compatible with conductor splice), Cleaning solvent, Clean cloth, Soldering equipment (optional, if not using constant force springs), Sanding tool (e.g., fine sandpaper), Heat gun
Supplies needed:
Joint Housing (15PCJ1H2290), PVC tape (various colors), Compression connector (copper or aluminum, compatible with cable conductor), Lubricant (supplied with joint kit), Heat shrink tube (supplied with joint kit), Mastic tape, Flat copper braid, Constant force springs (optional, if not soldering), Inhibitor (often supplied with connectors)
- Prepare for Installation and Ensure Safety
De-energize all apparatus in the work area before beginning installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, correct rating, and compatibility. Gather all required tools and supplies, ensuring a clean work environment. Read the entire installation instructions thoroughly before starting.
- Prepare Cable Jackets and Metallic Shields
Train both cables into their final position and square cut them, leaving approximately 5mm between the cable ends. Store the heat shrink tube onto either cable, out of the way. Remove the outer jackets from both cables to the dimensions specified in the provided table (e.g., 'A'). Carefully remove the cable metallic tape screen for the distance shown (e.g., 'B') and secure the ends with PVC tape. Ensure PVC tape covers only the copper tape and does not overlap onto the non-metallic screen.
- Prepare Non-Metallic Screens and Insulation
Carefully remove the cable non-metallic screen from both cables to the point specified (e.g., 'D'). Avoid nicking, cutting, or damaging the insulation surface or conductor strands. Bevel the edge of the insulation on Cable 1. Cut the insulation to the conductor to dimension 'E' from the end of both cables, but DO NOT remove this insulation. Install a PVC tape marker on Cable 2 at dimension 'B' from the jacket to locate the splice later.
- Temporarily Store Joint Housing and Prepare Cable 1
Apply one layer of PVC tape (half-lapped) over the metallic screen on Cable 1, starting at the jacket and extending 10mm beyond the end of the metallic screen. Install a different color PVC tape marker on Cable 1 at dimension 'B' from the jacket. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC-taped portion of the metallic tape screen on Cable 1. Store the joint housing onto Cable 1, sliding it up to the jacket. Ensure sharp edges of the metallic screen are covered with PVC tape to prevent damage to the housing.
- Remove Cable Insulation for Connector
Remove the cable insulation from both cables at the ends where the connector will be installed, to dimension 'E'. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor.
- Install and Crimp the Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert both conductors into the conductor splice, ensuring they are fully seated. Do not crimp yet. Check the distance between the cable insulations; if it exceeds the 'Check Dim (Before)' value, do not proceed. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and all metal chips or filings from the splice joint assembly area. Wipe off any excess inhibitor. Re-check the distance between the cable insulations; if it exceeds the 'Check Dim (After)' value, do not proceed.
- Clean and Lubricate the Core
Clean the conductor, connector, and Cable 2 insulation surfaces using cleaning solvent and a clean cloth. Always wipe towards the screen end to remove all contaminants. Lubricate the cable insulation surfaces using the supplied lubricant. Always wipe toward the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Position the Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape markers on both sides. Ensure that the distance 'X' is equal on each side of the joint housing. Remove the PVC tape applied in Step 4 to expose 25mm of the copper tape shield.
- Restore the Screen
Wrap flat copper braid around each side of the joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.
- Restore the Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm from the joint. Heat both sanded areas for approximately 15 seconds, being careful not to burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tube (stored in Step 2) over the center of the assembly and shrink it, starting at the center and working towards the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.