Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1M1330 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 25PCJ1M1330 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786665815


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25PCJ1M1330 is a 25kV power cable joint designed for medium-voltage applications requiring reliable, long-term cable connections. This joint accommodates aluminum conductors sized at 500 AWG stranded, with cable insulation diameters ranging from 1.370 to 1.630 inches. The single-piece housing simplifies installation by eliminating multiple components, reducing assembly time and potential failure points. The joint is rated for 25kV service, making it suitable for utility, industrial, and commercial power distribution systems where medium-voltage cable terminations are required. The aluminum conductor compatibility aligns with common utility-grade installations, ensuring compatibility with existing infrastructure. Installation requires proper cable preparation, including stripping to the specified insulation diameter, followed by securing the joint housing over the prepared cable ends. The joint is designed for indoor and outdoor use, with weather-resistant properties to withstand environmental exposure. The 25PCJ1M1330 is part of ABB's Style 1 cable joint series, which includes dimensional options for various cable sizes and insulation diameters. The housing dimensions for this specific model are 14 3/8" (A) by 2 25/32" (B). The joint includes a connector (02403XXX), lubricant tube (82-08), installation instructions (IS-0332, IS-0179, IS-0180, or IS-0182), and a crimp chart (CC-0038, CC-0039, or CC-0042). The product is engineered for medium-voltage power distribution systems, including utility, industrial, and commercial applications where reliable cable joints are critical for system integrity.
  • Rated for 25kV medium-voltage applications
  • Accommodates 500 AWG stranded aluminum conductors
  • Single-piece housing simplifies installation and reduces failure points
  • Cable insulation diameter range: 1.370" to 1.630"
  • Designed for utility, industrial, and commercial power distribution systems

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ1M2330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2G1230-F1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ1G2250

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

25PCJ1G1210

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.

35PCJ1P1400

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J2280-J2270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

28PCJ1J1260

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

Frequently Asked Questions

What material are PCJ power cable joints made from?

PCJ power cable joints feature permanently crimped connectors inside ethylene propylene diene monomer (EPDM) rubber housings.

What are the benefits of the pre-molded rubber housing?

The pre-molded rubber housing offers exceptional protection, extended shelf life compared to cold-shrink splices, and long-lasting service life in harsh environments.

What type of connector is included for aluminum conductor splicing?

Kits for aluminum conductor splicing include an aluminum compression connector suitable for aluminum-to-aluminum or aluminum-to-copper connections.

What is the continuous current rating of PCJ power cable joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

Where are Elastimold PCJ power cable joints manufactured and tested?

Elastimold PCJ power cable joints are assembled and 100% factory tested in Albuquerque, New Mexico, USA.

What pull force can the pin-and-socket interlock withstand?

The pin-and-socket interlock in PCJ power cable joints can withstand a pull force of up to 500 lb.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What conductor materials and sizes are compatible with PCJ joints?

PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are PCJ power cable joints available in?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15/25/35PCJ1 Series Cable Joint

This guide provides step-by-step instructions for the permanent installation of the 15/25/35PCJ1 series straight joint, designed for wire shielded cables with aluminum or copper conductors.

Estimated time: 2h

Tools needed:

Wire strippers, Wire brush, Crimping tool, T&B WT3D tool (for 35kV only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), DELTECt Cable ties (TYD5135, for 35kV only), No. 14 AWG copper wire (or equivalent, if needed), Appropriate connector (for grounding wires)

  1. Safety and Initial Inspection

    Before beginning, ensure all apparatus is de-energized. Inspect the package contents for completeness and damage. Verify all components are compatible with the cable and mating products. Read all instructions thoroughly and gather necessary tools, maintaining cleanliness throughout the procedure.

  2. Prepare Cables for Joint Centerline

    Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires, then cut both cables precisely at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, positioning it up to the shield wires.

  4. Prepare Cables for Splice

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. Refer to the provided diagrams for precise 'X' and 'Y' dimensions based on conductor size (e.g., 2 1/2 inches for 'Y' and 6 1/4 inches for 'X' for 500-750 MCM). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor.

  5. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the conductor insertion dimension against the 'Max Check Before' table (e.g., 6 inches for 500-750 MCM). Crimp the splice according to its recommendations. Wipe off any excess inhibitor. After crimping, check the distance between cable insulations against the 'Max Check After' table (e.g., 6 1/4 inches for 500-750 MCM). Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area. Clean the cables where indicated and lubricate them in the direction of the arrows to create a lubricant ramp at the insulation shield edge.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper alignment by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY, install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge and 1/4 inch from the first tie with offset locking heads, using a T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.