ABB Installation Products 35PCJ1P1400 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786667284
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated power cable joint
- Single-piece housing for simplified installation
- Accommodates cable insulation diameters from 1.725" to 1.935"
- Designed for 1000 AWG solid aluminum conductors
- Manufactured by ABB - Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 1000 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 15-3/4 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1Q1400
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15PCJ2J2280-J2270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
28PCJ1J1260
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
28PCJ1L1320
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
28PCJ1M1360
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35PCJ1P1360
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
115TCJS44136P5FDBNB
115kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Aluminum, Conductor Code 36P - .901-.935 inch Diameter, Heatsink Size 5 - 2.750 inch Outside Diameter, Heatsink Bore Diameter F - 1.015 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit B - 4/0 Bonding Cable 6 foot long quantity 2 with Split Bolts quantity 4, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
115TCJS32A31POOBNNB
115kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 3, Housing Size 2 - Bore Diameter 1.725 inch, Insulation Range 1.967-2.620 inch, Connector Type - Aluminum - No Connector Required, Conductor Code 31P - .687-.745 inch Diameter, Heatsink Size Not Included, Heatsink Bore Diameter Not Included, Type Shield B - Copper Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit - Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.Frequently Asked Questions
What is the difference between PCJ Style 1 and Style 2 joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
How should catalog numbers be constructed for transition joints?
When constructing a catalog number for a transition joint (two different-size cables), list the larger connector first and the smaller connector second.
What is the short-time current rating for PCJ cable joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating for PCJ cable joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
What pull force can the pin-and-socket interlock withstand?
The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force of up to 500 lb.
Which connector material should be used for different cable types?
Aluminum compression connectors are for aluminum-to-aluminum or aluminum-to-copper. Copper compression connectors are for copper-to-copper only and must not be used on aluminum.
What voltage classes are Elastimold PCJ joints available for?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What types of cable splicing can PCJ joints perform?
PCJ power cable joints can perform straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil.
What conductor materials are compatible with PCJ cable joints?
PCJ power cable joints can be used with both copper and aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.
How to Install the 35PCJ1P1400 Straight Joint
Installation guide for creating a permanent, fully shielded, and submersible straight joint for aluminum and/or copper conductor wire shielded cables.
Estimated time: 1h
Tools needed:
Wire brush, Crimping tool, Cable ties tightening tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant, Appropriate connector for grounding wires, DELTECt Cable ties (for 35kV only), Insulated cap(s) or connector(s) (if supplied with protective shipping cover)
- Prepare Cables for Joint
Overlap both cables and cut to 12" (305mm) from the center line of the joint. Remove the cable jacket of Cable 1 to 37" (940mm) and Cable 2 to 21" (530mm). Fold back the shield wires. Cut both cables at the center line of the joint.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1 insulation shield by 1/2" to 1-1/2" (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both cables. Ensure not to cut or nick the cable insulation or conductor. For 500-750 MCM cables, the conductor length should be 2 1/2" (64mm) and the insulation shield length 6 1/4" (159mm). For 1000 MCM cables, the conductor length should be 2 3/8" (68mm) and the insulation shield length 6 3/8" (162mm).
- Install Splice
If conductors are aluminum, wire-brush them and immediately insert into the splice. Crimp the splice following the manufacturer's recommendations. Wipe off excess inhibitor. Check the distance between cable insulations; if it exceeds the Max Check After dimension, redo the assembly. Remove any sharp protrusions or burrs from the splice. Clean the cables where indicated and lubricate in the direction of the arrows to create a ramp of lubricant at the edge of the insulation shield.
- Complete Joint Assembly
Slide the housing into its final position, ensuring proper alignment by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4" from the edge of the splice and then 1/4" from the first tie with an offset of the locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.