ABB Installation Products 15PCJ1G2250 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786666270
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating for medium voltage applications
- Single-piece housing for ease of installation
- Accommodates cable insulation diameters from 0.760" to 0.950"
- Suitable for copper conductors: stranded 2/0 AWG / solid 3/0 AWG
- ABB Installation Products quality and reliability
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 2/0 STR AWG , 3/0 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 15PCJ1G2250 |
Size | 14-3/8 inch long |
Size | 0.760 inch to 0.950 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8000 L |
Package Weight (Metric) | 0.3630 kg |

15PCJ1H2250
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
25PCJ1G1210
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
35PCJ1P1400
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15PCJ2J2280-J2270
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
28PCJ1J1260
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
28PCJ1L1320
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
28PCJ1M1360
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35PCJ1P1360
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 750.Frequently Asked Questions
What are the applications for PCJ power cable joints?
PCJ power cable joints are suitable for joining cable runs in new installations or repairing broken cables in existing installations. They provide a permanent, fully shielded, fully submersible splice.
What is the continuous current rating for PCJ joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
What type of connector is included in kits for aluminum conductors?
Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.
What is the DC withstand during installation for a 35 kV PCJ joint?
For a 35 kV class PCJ joint, the DC withstand during installation is 100 kV.
What is the corona extinction voltage for a 25 kV PCJ joint?
For a 25 kV class PCJ joint, the corona extinction voltage with 3 pC sensitivity is 22 kV.
What is the BIL impulse withstand for a 15 kV PCJ joint?
For a 15 kV class PCJ joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 110 kV.
What is the short-time current rating for PCJ joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
What pull force can the PCJ joint interlock withstand?
The pin-and-socket interlock of the PCJ power cable joint is designed to withstand a pull force of up to 500 lb.
What are the two styles of PCJ power cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
How to Install a Single Core Cable Joint (15PCJ1G2250)
This guide provides step-by-step instructions for the safe and proper installation of the 15PCJ1G2250 single core cable joint. It covers cable preparation, connector installation, and joint housing assembly for extruded solid dielectric cables.
Estimated time: 2h
Tools needed:
Wire strippers, Cable knife, Crimping tool, Wire brush, Cleaning solvent, Clean cloth, Soldering iron (optional, if not using constant force springs), Constant force spring tool (optional, if not soldering), Heat gun, Sandpaper or sanding tool
Supplies needed:
Joint Housing, PVC Tape (different colors recommended for markers), Conductor Splice (compression connector), Lubricant, Flat Copper Braid, Constant Force Springs (if not soldering), Mastic Tape, Heat Shrink Tube
- De-energize and Ensure Safety
Before beginning, ensure all apparatus in the work area are de-energized. Do not touch or move any energized products. This installation must be performed by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Inspect Components and Prepare Workspace
Check the package contents to ensure they are complete and undamaged. Verify all components to ensure proper fit with the cable and/or mating products. Read the entire installation instructions before starting. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare Cable Jackets and Metallic Shield
Train the cables into their final position and square cut, leaving approximately 5mm between cables. Store the heat shrink on either cable. Remove the jackets of both cables to the dimensions shown in the provided tables (e.g., 405mm for H, J, K sizes). Carefully remove the cable metallic tape screen for the distance shown (e.g., 125mm for H, J, K sizes) and secure the ends with PVC tape. Keep the PVC tape on the copper tape and do not overlap onto the non-metallic screen.
- Remove Non-Metallic Screen and Bevel Insulation
Carefully remove the cable non-metallic screen from both cables to the point specified in the tables (e.g., 45mm for H, J, K sizes). WARNING: DO NOT NICK, CUT OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for H, J, K sizes) from the end of both cables, DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for H, J, K sizes) to locate the splice later.
- Temporarily Store Joint Housing
Beginning at the jacket and proceeding 10mm beyond the end of the metallic screen, apply one layer (half lapped) of PVC tape over the metallic screen on Cable 1. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm for H, J, K sizes) to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket. WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing when storing it on the PVC taped portion of the cable. DO NOT STORE SPLICE HOUSING ON EXPOSED METALLIC TAPE SHIELD.
- Remove Cable Insulation
Remove cable insulation from both cables to dimension 'E' (e.g., 45mm for H, J, K sizes). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.
- Install Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between insulations. If it exceeds the “Before” dimension in the table (e.g., 108mm for H, J, K sizes), DO NOT PROCEED; review instructions and redo assembly. Crimp the conductor splice according to the crimp chart provided. Remove any sharp protrusions or burrs. Metal chips or filings must be removed from the splice joint assembly area prior to sliding the joint. Wipe off all excess inhibitor. Check the distance between cable insulations again. If it exceeds the “After” dimension in the table (e.g., 102mm for H, J, K sizes), DO NOT PROCEED; review instructions and redo assembly.
- Clean and Lubricate Cable Cores
WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth. Always wipe towards the screen end. Lubricate cable insulation surfaces using the lubricant supplied. Always wipe toward the screen end to provide build-up or ramp of lubricant at the edge of the non-metallic screen.
- Install Joint Housing into Final Position
Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker; the distance “X” should be equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape.
- Restore Screen
Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.
- Restore Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds; WARNING: DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the Jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.