Authorized ABB Distributor (Installation Products)
ABB - Installation Products 25PCJ1G1210 - 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

ABB Installation Products 25PCJ1G1210 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786666805


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 25PCJ1G1210 is a 25kV power cable joint designed for medium-voltage cable systems requiring reliable, high-integrity splices. This joint accommodates cable insulation diameters between 0.760 inch and 0.950 inch, making it suitable for applications where precise fitment is critical. The single-piece housing simplifies installation and reduces the risk of misalignment or contamination during assembly. This joint supports both stranded (#3 AWG) and solid (#2 AWG) aluminum conductors, providing versatility for different cable configurations. The aluminum conductor compatibility aligns with common utility and industrial power distribution systems, where aluminum conductors are frequently used for cost efficiency and weight reduction. The 25kV rating ensures compatibility with medium-voltage distribution networks, including underground and aerial installations. The joint is engineered for use in power utilities, industrial facilities, and commercial infrastructure where medium-voltage cable systems are deployed. Installation follows standard splicing procedures, with the single-piece housing designed to streamline the process and minimize labor time.
  • 25kV rated for medium-voltage cable systems
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters 0.760" to 0.950"
  • Supports #3 AWG stranded and #2 AWG solid aluminum conductors
  • Designed for underground and aerial power distribution applications

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#3 STR AWG , #2 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F1210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.

35PCJ1P1400

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J2280-J2270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.

28PCJ1J1260

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

28PCJ1L1320

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

28PCJ1M1360

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

35PCJ1P1360

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
115kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Aluminum, Conductor Code 36P - .901-.935 inch Diameter, Heatsink Size 5 - 2.750 inch Outside Diameter, Heatsink Bore Diameter F - 1.015 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit B - 4/0 Bonding Cable 6 foot long quantity 2 with Split Bolts quantity 4, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

115TCJS44136P5FDBNB

115kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Aluminum, Conductor Code 36P - .901-.935 inch Diameter, Heatsink Size 5 - 2.750 inch Outside Diameter, Heatsink Bore Diameter F - 1.015 inch, Type Shield D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit B - 4/0 Bonding Cable 6 foot long quantity 2 with Split Bolts quantity 4, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

Frequently Asked Questions

What standards do the joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the short-time current rating?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating?

The continuous current rating of the PCJ power cable joints is equal to that of the cable rating.

What is the maximum conductor size supported?

These power cable joints support conductor sizes up to 1250 kcmil for both copper and aluminum conductors.

Where can these cable joints be installed?

They provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ joints?

Style 1 is for straight splicing of two similar cables, while Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What types of conductors are compatible?

The joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What are the available voltage classes?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ joints?

Style 1 is for straight splicing of two similar cables, while Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What standards do the joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

How to Install the ABB 15/25/35PCJ1 Straight Joint

This guide provides step-by-step instructions for installing the ABB 15/25/35PCJ1 straight joint, a permanent, fully shielded, and submersible joint for wire shielded cables.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife or cable stripping tool, Wire brush (for aluminum conductors), Crimping tool, Measuring tape or ruler, T&B WT3D tool (for 35kV installations only)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), User-supplied connector (for grounding wires), DELTECt Cable ties (for 35kV installations only), #14 AWG copper wire (if shield wires are smaller than #14 AWG)

  1. Prepare for Installation and Ensure Safety

    De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Inspect all package contents and components for damage, proper rating, and compatibility with mating parts. Gather all required tools and supplies, ensuring cleanliness throughout the procedure.

  2. Initial Cable Preparation

    Overlap both cables and cut them to 12 inches (305mm) from the centerline of the joint to ensure sufficient length of shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the centerline of the joint.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires; this procedure will not contaminate electrical interfaces.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. Measure and ensure the correct 'X' and 'Y' dimensions for the conductor and insulation shield removal, referring to the provided dimension table for your specific conductor size (e.g., 500 MCM - 750 MCM or 1000 MCM).

  5. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; redo assembly if it exceeds this. Crimp the splice following the manufacturer's recommendations provided with it. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table; redo assembly if it exceeds this. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area. Clean the cables where indicated and lubricate them in the direction of the arrows to provide a build-up or ramp of lubricant at the edge of the insulation shield.

  6. Complete Joint Assembly

    Slide the housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice, then install a second tie approximately 1/4 inch (6mm) from the first with an offset of the locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.