Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1G2300 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.

ABB Installation Products 15PCJ1G2300 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114169059


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15PCJ1G2300 is a 15kV power cable joint designed for copper conductors with insulation diameters between 0.760 inch and 0.950 inch. This single-piece housing joint accommodates AWG stranded 350 copper conductors, providing a reliable solution for medium-voltage cable connections in industrial and utility applications. The joint is engineered for quick installation, reducing downtime during maintenance or upgrades. Its compact design and compatibility with standard cable sizes make it ideal for retrofits or new installations where space is constrained. The single-piece housing simplifies assembly, eliminating the need for multiple components and reducing the risk of installation errors. This joint is suitable for both indoor and outdoor environments, ensuring consistent performance in varying conditions. The 15kV rating supports applications requiring medium-voltage power distribution, including substations, industrial plants, and renewable energy installations. The ABB 15PCJ1G2300 meets industry standards for safety and reliability, providing a durable connection that minimizes electrical resistance and heat generation. For projects requiring a dependable medium-voltage cable joint, the 15PCJ1G2300 delivers performance with minimal maintenance.
  • 15kV rated power cable joint for medium-voltage applications
  • Single-piece housing for simplified installation and reduced error risk
  • Compatible with copper conductors 0.760" to 0.950" insulation diameter
  • Supports AWG stranded 350 copper conductor size
  • Suitable for indoor and outdoor environments

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
350 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1H2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cold-Shrinkable Jacket Seal Included.

35PCJ1K1250-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cold-Shrinkable Jacket Seal Included.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified, For Qatar

69TCJS45DP0597945-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified, For Qatar
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350. Cold-Shrinkable Jacket Seal Included.

35PCJ1L1290-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2J1270-F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Jacket Seal included.

35PCJ1J1230S

35kV Power Cable Joint Style 1, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Jacket Seal included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ2F2240

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ2H1250-H1240

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

Frequently Asked Questions

What voltage rating does this cable joint support?

This cable joint is rated for 15kV medium-voltage applications.

What is the insulation diameter range for this joint?

The joint accommodates cable insulation diameters from 0.760 inch to 0.950 inch.

What conductor sizes are compatible with this joint?

The joint supports AWG stranded 350 copper conductors.

Is this joint suitable for outdoor installations?

Yes, the single-piece housing design is suitable for both indoor and outdoor environments.

How to Install the 15PCJ1G2300 Single Core Joint

This guide provides step-by-step instructions for the permanent installation of the 15PCJ1G2300 single core joint, designed for extruded solid dielectric cables with copper or aluminum conductors.

Estimated time: 1h 30m

Tools needed:

Cable stripping tools, Wire brush, Crimping tool, Cleaning cloth, Soldering iron (or constant force spring tool), Heat gun, Measuring tape

Supplies needed:

PVC tape, Conductor splice, Inhibitor, Cleaning solvent, Lubricant, Flat copper braid, Constant force spring (optional), Mastic tape, Heat shrink

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all joint components for damage, proper rating, and compatibility with mating cable parts. Gather all required tools and maintain cleanliness throughout the procedure.

  2. Prepare Cable Jackets and Metallic Shields

    Train the cables into their final position, square cut them, leaving approximately 5mm between cables. Store the heat shrink on either cable. Remove the jackets of both cables to the specified dimensions (refer to 'A' in table 1F-1G). Carefully remove the cable metallic tape screen for the specified distance (refer to 'B' in table 1F-1G) and secure the ends with PVC tape. Ensure PVC tape is only on the copper tape and does not overlap onto the non-metallic screen.

  3. Prepare Non-Metallic Screens and Cable Insulation

    WARNING: DO NOT NICK, CUT, OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the point specified (refer to 'D' in table 1F-1G). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (refer to table 1F-1G) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (refer to table 1F-1G) to locate the splice later.

  4. Temporarily Store the Joint Housing

    Beginning at the jacket and extending 10mm beyond the end of the metallic screen, apply one layer (half-lapped) of PVC tape over the metallic screen. WARNING: The forward edge and any other sharp edges of the metallic screen must be covered with PVC tape to prevent damage to the joint housing. Install a different color PVC tape marker on Cable 1 to dimension 'B' (refer to table 1F-1G). Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and the PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket; DO NOT store the splice housing on the exposed metallic tape shield.

  5. Remove Cable Insulation

    Remove the cable insulation from both cables to dimension 'E' (refer to table 1F-1G). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.

  6. Install the Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between the insulations; if it exceeds the 'Check Dim (Before)' in table 1F-1G, review instructions and redo. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and metal chips/filings from the splice joint assembly area. Wipe off all excess inhibitor. Check the distance between cable insulations again; if it exceeds the 'Check Dim (After)' in table 1F-1G, review instructions and redo.

  7. Clean and Lubricate the Core

    WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces using the supplied lubricant, always wiping toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.

  8. Install the Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on each side; ensure these distances are equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape.

  9. Restore the Screen

    Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.

  10. Restore the Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds; DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.