Overview
- Self forming screw included
- Weights are installed from the bottom of the Flex Base
- Allows for installation of up to four weight pieces per Flex Base.
- Designed for seamless integration with the SYSPEND 180-MAX suspension system.
- Provides crucial counterbalancing for enhanced structural rigidity.
Specifications
Material | Aluminum |
Series | Syspend 281-Max |
Size | 110x80x30 |
Size | 110x80x30 mm |
Package Dimensions (L x W x H) | 2 IN x 2 IN x 2 IN |
Package Dimensions (L x W x H) | 5.08 cm x 5.08 cm x 5.08 cm |
Package Weight (Imperial) | 2.000 L |
Package Weight (Metric) | 0.907 kg |
How to Install the Flex.Base for Suspension Systems
This guide details the mechanical assembly, earthing, and optional components installation for the Flex.Base, which serves as a ground-contacting base for suspension systems or stand columns supporting HMI devices.
Estimated time: 1h
Tools needed:
Torque wrench (capable of 1.5 Nm, 2 Nm, 3 Nm, 5 Nm, 12 Nm), Screwdriver (appropriate for M5, M8, M12 screws), Wrench (appropriate for M8, M12 screws)
Supplies needed:
Adapter plate (e.g., S2MSYSAPG), Earthing screws (M5), M8x20 screws, M12x12 screws, M5x40 self-tapping screws, Closure plate, M5x10 screws, Optional weights, Adjustable feet (S2MFBC) or castors (S2MFBF), Earthing cable, Cover plate for cable entries
- Prepare for Installation and Safety Precautions
Before starting, ensure the power supply is disconnected and suitable protective measures are in place to prevent electric shock. Read all safety instructions. Ensure the mounting surface is flat, even, and sufficiently load-bearing. Only experienced, trained electricians and fitters should perform this installation. Be aware of possible sharp edges on the underside of the Flex.Base.
- Install the Adapter Plate
Screw the appropriate adapter plate (e.g., S2MSYSAPG) onto the Flex.Base. Use the specified M8x20 and M12x12 screws. Tighten all screws to a torque of 12 Nm. Ensure the adapter plate is firmly attached.
- Install the Earthing System
Carry out necessary earthing and wiring measures. Tighten the M5 earthing screws to 2 Nm. For customer connections, tighten screws to 1.5 Nm. Ensure all earthing cross-sections are sufficiently dimensioned and the protective conductor system is properly installed before operation. Do not damage seals during installation, and avoid excessive crushing, stretching, or bending of power lines. The electrical connection must be carried out by a qualified electrician.
- Connect the Suspension System
Connect the suspension system to the installed adapter plate. Refer to the specific technical data sheets for the suspension system for detailed connection instructions and load specifications. Ensure all connections are secure and meet static load requirements (F max. 900N, Tilting moment max. 20 Nm).
- Install Optional Weights (if required)
If increased stability is required, install up to four optional weights. Screw each weight in with two M5x40 self-tapping screws. Tighten these screws to a torque of 5 Nm.
- Install the Closure Plate
Insert the closure plate into its designated position. Fasten the plate using the 8x M5x10 screws. Tighten these screws to a torque of 3 Nm.
- Install Castors or Adjustable Feet
Mount either the apparatus castors (S2MFBF) or the adjustable support feet (S2MFBC) to the base. For support feet, ensure a minimum screw depth of 10mm and tighten to a maximum torque of 5 Nm. If using castors, ensure the selected cable lengths allow for movement and provide appropriate strain relief for outgoing cables. Remove any objects in the moving area to ensure safe movement and prevent tilting.
- Install Cable Entry Cover Surfaces (if applicable)
If applicable, install cover surfaces for cable entries. Fasten any screws for these covers to a torque of 2 Nm. Ensure seals are not damaged during installation to maintain the specified IP54 protection class. The operating company is responsible for proper sealing and compliance with tightening torques.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.