Contact for Pricing
Overview
- Mounts at end of support tube
- Helps keep dirt, dust, and water out
- Dimensions: 72x92x20mm for precise fit.
- Enhances the aesthetic finish of industrial support systems.
- From nVent, a trusted leader in electrical protection solutions.
Specifications
Application | Controls and Drives |
Color | White Aluminum |
Color Code | RAL 9006 |
Depth | 20 mm |
Depth | 0.79 in |
Finish | Powder Coated |
Height | 2.83 in |
Height | 72 mm |
Material | Aluminum |
Product Family | Syspend 281-Max |
Protection Rating | IP65 |
Type | Syspend 281-Max |
Weight | 0.25 lb |
Width | 3.622 in |
Width | 92 mm |
Width | 3.62 in |
Package Dimensions (L x W x H) | 2 IN x 2 IN x 2 IN |
Package Dimensions (L x W x H) | 5.08 cm x 5.08 cm x 5.08 cm |
Package Weight (Imperial) | 2.000 L |
Package Weight (Metric) | 0.907 kg |
How to Install the S2MESTC End Cap
This guide provides step-by-step instructions for securely mounting the S2MESTC End Cap onto the open ends of a support tube, ensuring proper sealing and preventing component slippage.
Estimated time: 10m
Tools needed:
Allen key (SW 5 recommended), Torque wrench
Supplies needed:
S2MESTC End Cap, Screws (included with end cap), Screw seals (included with end cap), Lubricating oil, Limit stop screw
- Prepare Components and Position End Cap
Before screwing, push the screw seals onto the screws. Then, place the S2MESTC end cap onto the end of the support tube. Ensure the end cap is correctly aligned with the tube.
- Install First Two Screws
Screw in one screw completely, applying oil for lubrication to facilitate the process. Next, screw in the diagonally opposite screw, ensuring its seal is properly seated.
- Install Remaining Screws
Finally, screw in the other two remaining screws completely, also using oil for lubrication. Ensure all screws are engaged but not yet fully tightened.
- Tighten All Screws to Specified Torque
Tighten all four screws to a torque of 5 Nm. Ensure the end cap is firmly secured and the seals are not damaged during this process. Do not overtighten.
- Install Limit Stop Screw
Install the limit stop screw in the tube region near the end cap. This screw is crucial to prevent the ERGO.SLIDE component from slipping over the end cap. If a thread for the screw is not present, it must be retrofitted.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.