The **nVent Sequestr External Disconnect Package (SKU: A84XD7818FTCLP)** is a critical safety solution designed to enhance electrical system reliability and worker protection in industrial environments. This pre-assembled package integrates a disconnect switch and fuse block or circuit breaker into a dedicated external enclosure, ensuring that incoming power is isolated before maintenance personnel access the main enclosure. By separating high-risk electrical components from operational areas, the Sequestr system significantly reduces the potential for arc flash incidents, electrical faults, and unplanned downtime—making it an essential component for facilities prioritizing safety and compliance with NFPA 70E, OSHA, and other regulatory standards. Engineered for **Type 12 enclosures** (84.12 x 78.50 x 18.12 inches), this package is ideal for harsh industrial settings where dust, dirt, and moisture resistance are paramount. The external enclosure is constructed from durable **gray steel**, providing robust protection against environmental contaminants while ensuring long-term durability in demanding applications. The design allows for seamless integration into new installations, with pre-wired terminal connections that simplify power routing to the main enclosure, reducing installation time and labor costs. **Key Applications and Industries** The Sequestr External Disconnect Package is widely utilized across multiple sectors where electrical safety and operational efficiency are critical: - **Manufacturing Facilities**: Protects workers in assembly lines, CNC machining centers, and robotic work cells by isolating power during maintenance. - **Data Centers**: Ensures safe access to server racks and power distribution units (PDUs) by isolating circuits during upgrades or repairs. - **Food & Beverage Processing**: Meets stringent hygiene and safety standards by preventing contamination risks associated with electrical faults in washdown environments. - **Oil & Gas Refineries**: Mitigates explosion hazards in classified hazardous locations by providing a secure disconnect mechanism for high-voltage equipment. - **Water/Wastewater Treatment Plants**: Safeguards personnel working on pumps, filtration systems, and control panels in wet or corrosive conditions. **Why Choose nVent for External Disconnect Solutions?** As a global leader in electrical and thermal management solutions, **nVent** (formerly part of Tyco Electronics) brings decades of expertise to its Sequestr product line. The company’s commitment to innovation is evident in the Sequestr’s modular design, which allows for easy customization with additional accessories such as lockout/tagout (LOTO) devices, surge protection modules, or remote monitoring interfaces. nVent’s reputation for reliability is further bolstered by rigorous testing, including UL/cUL listings and compliance with international standards like IEC 62208 for enclosures. **Installation and Operational Benefits** Professionals in the electrical trades recognize the Sequestr External Disconnect Package as a **best-in-class solution** for several reasons: - **Enhanced Safety**: Isolates live circuits before enclosure access, reducing arc flash hazards by up to 90% in compliant installations. - **Simplified Maintenance**: Pre-assembled and shipped as a single unit, minimizing on-site assembly errors and accelerating deployment. - **Flexible Configuration**: Compatible with both fuse blocks and circuit breakers, allowing engineers to tailor the system to specific load requirements. - **Durability**: Corrosion-resistant steel construction and Type 12 rating ensure reliable performance in indoor and outdoor environments. - **Future-Proofing**: Modular design supports easy upgrades or retrofits, extending the system’s lifespan and reducing total cost of ownership. For electrical contractors, facility managers, and safety engineers, the **nVent Sequestr External Disconnect Package (A84XD7818FTCLP)** represents a proactive investment in safety, compliance, and operational continuity. Whether specified for new construction or retrofitting existing systems, this solution delivers unmatched protection and peace of mind in high-stakes industrial environments.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Arc Flash Safety; Controls and Drives; Power Distribution
Color
Gray
Connection Type
Pre-wired Terminal
Depth
18.12 in
Depth
460 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
84.12 in
Height
2,137 mm
Interior Color
White
IP Rating
IP55
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting Type
External Enclosure Mount
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A84PM78
Panel Size
1829 x 1829 mm
Panel Size
72.00 x 72.00 in
Product Family
Sequestr
Protection Rating
NEMA Type 12
Series
Sequestr
Size
84.12 x 78.50 x 18.12 inches
Size
84.12x78.50x18.12 in
Stiffener Locations
910 mm
Stiffener Locations
24 in
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
970 lb
Width
1,994 mm
Width
78.5 in
Package Dimensions (L x W x H)
84 IN x 36 IN x 94 IN
Package Dimensions (L x W x H)
213.36 cm x 91.44 cm x 238.76 cm
Package Weight (Imperial)
970.000 L
Package Weight (Metric)
439.992 kg
Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x18.12, Gray, Steel

A72XD7818FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 72.12x78.50x18.12, Gray, Steel

How to Install the Sequestr External Disconnect Enclosure

This guide provides step-by-step instructions for installing the Sequestr external disconnect enclosure to a control enclosure, ensuring proper mounting, wiring, and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Drill

Supplies needed:

Mounting screws, Terminal connectors, Hoffman hole seal, Hoffman blank adapter plate

  1. Power Down the System

    Turn off the local disconnect in the control enclosure and the feeder disconnect. Put on appropriate Personal Protective Equipment (PPE) and open the control enclosure.

  2. Prepare the Control Enclosure

    Remove the existing disconnect from the control enclosure and seal the hole with a Hoffman hole seal. Cover all components in the control enclosure to protect them.

  3. Mount the Sequestr Enclosure

    Remove the subpanel from the Sequestr enclosure. Drill a hole for the power line entrance, then hang the Sequestr enclosure on the control enclosure using M6x16mm bolts. Secure it with washer head cap screws from inside the control enclosure.

  4. Install the Circuit Breaker

    Drill mounting holes for the circuit breaker on the panel. Install the circuit breaker according to the manufacturer's instructions and secure the panel back into the Sequestr enclosure.

  5. Connect Wiring

    Install conduit and connect wires to the incoming side of the circuit breaker in the Sequestr enclosure. Ensure all connections are secure.

  6. Power Up the System

    Remove any protective coverings, ensure the operator handle is in the 'OFF' position, close and latch both the Sequestr and control enclosure doors, then turn on the feeder disconnect switch and verify system operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.