nVent A72XD3EQ18FTCLP - Sequestr External Disconnect Pkg Wht In Type 12, 72.12x100.75x18.12, Gray, Steel
nVent

A72XD3EQ18FTCLP

UPC: 783510169466


Documents & Media
Installation Instructions

Contact for Pricing

Overview

Enhance electrical safety and operational efficiency with the nVent Sequestr External Disconnect Enclosure Package (SKU: A72XD3EQ18FTCLP). Designed to significantly mitigate arc flash hazards, this robust package isolates incoming power from the main electrical enclosure, providing a critical safety barrier for personnel performing maintenance or working on interior components. This integrated solution simplifies new installations by shipping as a single, pre-assembled unit, streamlining the setup process and reducing on-site labor. The Sequestr External Disconnect Package features a high-quality steel enclosure, finished in a durable gray powder coating for enhanced corrosion resistance and longevity in demanding industrial environments. The Type 12 rating ensures protection against dust, falling dirt, and dripping water, making it suitable for a wide range of indoor applications where environmental contaminants are a concern. The enclosure dimensions of 72.12 x 100.75 x 18.12 inches provide ample space for the integrated disconnect switch and fuse block or circuit breaker, ensuring reliable power isolation. Key benefits of implementing the nVent Sequestr External Disconnect Package include: * **Arc Flash Mitigation:** By physically separating incoming power, the risk of arc flash incidents during internal enclosure work is dramatically reduced, safeguarding personnel and equipment. * **Streamlined Installation:** Shipped as a complete package, it eliminates the need for separate component sourcing and assembly, accelerating project timelines. * **Enhanced Safety:** Provides a clear and accessible point of disconnect, ensuring that power is safely de-energized before any internal work commences. * **Durable Construction:** Constructed from robust steel with a protective gray finish, it is built to withstand harsh industrial conditions. * **Versatile Application:** The Type 12 rating makes it suitable for various indoor industrial settings, protecting against common environmental hazards. This package is an essential component for facilities prioritizing safety and compliance with electrical safety standards. The integrated disconnect switch and fuse block/circuit breaker are expertly mounted within the external enclosure, with clearly defined terminal connections designed to efficiently route power to the main enclosure. nVent is a globally recognized leader in electrical connection and protection solutions, known for its commitment to innovation, quality, and reliability. Choosing the Sequestr External Disconnect Package means investing in a proven solution from a trusted manufacturer, ensuring peace of mind and operational continuity. This product is ideal for use in manufacturing plants, processing facilities, data centers, and any application where electrical safety is paramount.
  • Interlocks doors of main control cabinet when disconnect switch is powered ON
  • Mechanical interlock on main control enclosure activated by master door prevents slave door from being opened first
  • Provision for pass-through power into the main enclosure
  • Preferred disconnect cutout
  • Quarter-turn, screwdriver slot latch on Sequestr Enclosure
  • Rugged PowerGlide Handle with three-point latch on main control enclosure
  • Concealed, easy-to-remove hinges
  • Grounding studs on body
  • Bonding provision on door
  • Conductive back panel included in Sequestr External Disconnect Enclosure

Specifications

Application
Arc Flash Safety; Power Distribution; Controls and Drives
Color
Gray
Depth
460 mm
Depth
18.12 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Height
72.12 in
Height
1,832 mm
Interior Color
White
IP Rating
IP55
IP Rating
IP66
Large Panel
A72PM66
Large Panel Quantity
1
Large Panel Size
60.00 x 60.00 in
Large Panel Size
1524 x 1524 mm
Material
Steel
Material
Mild Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Product Family
Sequestr
Protection Rating
NEMA Type 12
Series
Sequestr
Size
72.12x100.75x18.12 inches
Size
72.12x100.75x18.12 in
Small Panel
A72PM34
Small Panel Size
60.00 x 27.75 in
Small Panel Size
1524 x 705 mm
Thickness
1.52 mm
Thickness
16 ga
Type
Mild Steel Freestanding Industrial Disconnect Enclosures
Type Number
Type 12
Weight
1,135.75 lb
Width
100.75 in
Width
2,559 mm
Package Dimensions (L x W x H)
129 IN x 36 IN x 80 IN
Package Dimensions (L x W x H)
327.66 cm x 91.44 cm x 203.2 cm
Package Weight (Imperial)
1135.750 L
Package Weight (Metric)
515.176 kg
Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel

A84XD7824FTCLP

Sequestr External Disconnect Pkg Wht In Type 12, 84.12x78.50x24.12, Gray, Steel

How to Install the WS74XM7524SS Enclosure

This guide provides step-by-step instructions for safely installing the WS74XM7524SS enclosure, ensuring proper handling and setup.

Estimated time: 1h

Tools needed:

Forklift, Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, 3000 lb-rated chain or strap

  1. Prepare the installation area

    Clear the installation route of all obstructions and ensure that workers are at a safe distance, more than the overall height of the enclosure.

  2. Secure the enclosure for transport

    Using a forklift, insert a 3000 lb-rated chain or strap through the eye bolts on top of the enclosure and securely fasten it to the forklift mast. Ensure sufficient tension to prevent tipping.

  3. Lift and position the enclosure

    Carefully lift the enclosure using the forklift, ensuring it is clear of the ground. Position the enclosure at the desired installation location.

  4. Mount the enclosure

    Secure the enclosure to the mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  5. Connect electrical components

    Use wire strippers to prepare the wires and connect them to the terminal connectors as per the wiring diagram provided. Verify connections with a multimeter.

  6. Calibrate the enclosure

    Follow the manufacturer's instructions to perform any necessary calibration of the enclosure's components to ensure proper functionality.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.