Overview

The Panduit FDC9N-24-LAULH FlexCore Front Access ODF Fiber Optic Cassette is engineered for high-density singlemode (OS2) fiber optic deployments. This universal cassette features 24 fibers, transitioning from 2x MPO-12 connectors to 24 LC/APC duplex connectors. It is designed for standard insertion loss (IL) performance, ensuring reliable signal transmission. The left-hand orientation of the MPO connectors simplifies cable management and installation within ODF (Optical Distribution Frame) systems. This cassette is manufactured by Panduit in the US, ensuring quality and adherence to industry standards. Its SKU is FDC9N-24-LAULH. The UNSPSC code is 43223310. This solution is ideal for data centers, telecommunications networks, and enterprise environments requiring efficient fiber termination and management. The front access design allows for easy servicing and patching without disrupting adjacent cassettes. Its universal compatibility ensures integration into various ODF configurations. The LC/APC connectors provide low back reflection, crucial for sensitive optical applications. The MPO connectors facilitate rapid deployment of high-fiber-count links. This cassette offers a structured approach to fiber optic connectivity, maximizing port density and minimizing installation complexity. It is a key component for building scalable and maintainable fiber optic infrastructure.
  • 24-fiber Singlemode (OS2) capacity
  • LC/APC Duplex to 2xMPO-12 connector transition
  • Universal design for flexible integration
  • Standard Insertion Loss (IL) performance
  • Left Hand Orientation for simplified cable management

Specifications

Application
FlexCore ODF/OSF
Color
Black
Connection
MPO
Connector 1 Type*
LC Duplex
Connector 2 Type*
MPO-12 Male
Fiber Type
OS2
Insertion Loss
0.75
Material
Polycarbonate
Standard
ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5, (FOCIS-5), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC compliant, supports IEEE802.3 and ANSI T11.2 (Fiber Channel)
Type
Fiber Cassette
Package Dimensions (L x W x H)
9.9 IN x 13 IN x 1.3 IN
Package Weight (Imperial)
0.81 lbs
FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL

FDS9N-24-10R

FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL
OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC Cassette, Left side Blunt end, Ultra Insertion Loss, No pulling Eye - 50 Feet

FZUYPXLNNNNF050

OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC Cassette, Left side Blunt end, Ultra Insertion Loss, No pulling Eye - 50 Feet
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM5) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Right Hand Orientation

FDCWA-24-10ASRH

FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM5) 24-fiber LC Duplex to 2xMPO-12, Method A Straight, Ultra IL, Right Hand Orientation
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC/APC Cassette, Left side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters

F9UYBZLNNSNM015

OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC/APC Cassette, Left side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Right Hand Orientation

FDCZA-24-10URH

FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Right Hand Orientation
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC/APC Cassette, Left side Blunt end, Standard Insertion Loss, No pulling Eye - 50 Feet

F9UYPZLNNSNF050

OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Plenum, FlexCore Front Access ODF LC/APC Cassette, Left side Blunt end, Standard Insertion Loss, No pulling Eye - 50 Feet
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation

FDCZA-24-10ULH

FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Universal, Standard IL, Left Hand Orientation

FDC9N-24-10ULH

FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Universal, Standard IL, Left Hand Orientation

Frequently Asked Questions

What is the fiber capacity of a FlexCore frame?

A single 600mm FlexCore frame has a maximum capacity of 3168 fibers, supporting 132 x 24F LC cassettes within 11 x 4 RU enclosures.

What are the dimensions of a single FlexCore frame?

A single 600mm FlexCore frame is 2133mm high (2159-2200mm with leveling feet), 1050mm wide, and 300mm deep.

What types of cassettes are compatible with FlexCore frames?

FlexCore frames accept MPO-LC, LC-Tethered, LC-Splice, and Splice-Through cable cassettes. They are not suitable for HD Flex™ Cassette styles.

What is the fiber count and connector type for FDC9N-24-LAULH?

The FDC9N-24-LAULH is a 24-fiber OS2 LC APC (Duplex) to 2 x MPO12 cassette with Universal Polarity and Left Hand cable entry.

What type of patch cords are required for a Double Frame (Compact)?

Duplex LC patch cords must be less than 2mm outside diameter unitary cable (Uniboot patch cord) for the Double Frame (Compact) Cross Connect.

What are the available modular building block widths for FlexCore?

FlexCore offers modular building blocks with widths of 150mm, 300mm, and 600mm for frame units and VCMs.

Are FlexCore frames supplied with leveling feet?

Yes, FlexCore frames are supplied with leveling feet and a wall mount bracket.

Does the FlexCore ODF meet seismic requirements?

Yes, the robust ODF frame offers configuration options that meet Telcordia Zone 3 seismic requirements.

What is the recommended patch cord length for a double FlexCore frame?

The recommended patch cord length for a double FlexCore frame is 4m. For a cross-connect four-frame lineup, 10m patch cords are recommended.

Can the FlexCore ODF be secured with locks?

Yes, the FlexCore ODF offers multi-layer security with lock capability available at both the 4 RU enclosure and ODF doors.

How to Install the FlexCore 4RU Universal Enclosure

This guide provides step-by-step instructions for installing the FlexCore 4RU Universal Enclosure in a rack, including mounting, wiring, and labeling.

Estimated time: 1h

Tools needed:

Phillips head screwdriver

Supplies needed:

#10-32 X 1/4” screws, Mounting brackets, Cable ties, Labels

  1. Remove the shipping bracket

    Unscrew the Phillips head screws on the top and bottom of the enclosure to remove the shipping bracket.

  2. Mount the enclosure

    Secure the enclosure to the rack using a minimum of four #10-32 X 1/4” screws. If RU space is open above, pre-install two screws on each side to assist in mounting.

  3. Install cassettes

    Open the enclosure door, slide the tray out to the cassette change position, and install or replace cassettes as needed. Ensure to disconnect any patch cords if replacing.

  4. Route and secure cables

    Install patch cords into the front of the cassettes from bottom to top, and use Tak-ty cable ties to secure incoming cables close to the tray cable manager.

  5. Label the enclosure

    Apply the provided labels to the enclosure and trays according to the EIA606-B labeling standards for easy identification.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.