Authorized Panduit Distributor
Panduit FDCZA-24-10ULH - FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation

Panduit FDCZA-24-10ULH FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM4) 24-fiber LC Duplex to…

UPC: 613056832770


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit FlexCore Front Access ODF Fiber Optic Cassette, SKU FDCZA-24-10ULH, is engineered for efficient fiber management in high-density data center and enterprise network environments. This universal cassette features Multimode OM4 fiber, supporting 24 fibers through a configuration of 24 LC Duplex ports on the front, connecting to two MPO-12 connectors on the rear. The Ultra IL (Insertion Loss) rating ensures minimal signal degradation, crucial for maintaining network performance and reliability. Designed for left-hand orientation within Panduit ODF (Optical Distribution Frame) systems, this cassette facilitates organized cable routing and simplified access for maintenance and upgrades. Its robust construction and precise fiber termination meet the demands of modern network infrastructure, enabling seamless data transmission and scalability. The FDCZA-24-10ULH is manufactured in the USA, adhering to stringent quality standards for dependable operation. This cassette is ideal for applications requiring high-speed data transfer and efficient port density, such as backbone connectivity, server interconnects, and structured cabling systems.
  • Multimode OM4 fiber support for high bandwidth applications
  • 24 LC Duplex ports on the front for easy termination
  • Dual 2xMPO-12 connectors on the rear for high-density connectivity
  • Ultra IL rating for minimal signal loss
  • Left-hand orientation for optimized ODF integration

Specifications

Application
FlexCore ODF/OSF
Color
Black
Connection
MPO
Connector 1 Type*
LC Duplex
Connector 2 Type*
MPO-12 Male
Fiber Type
OM4
Insertion Loss
0.35 dB
Material
Polycarbonate
Standard
ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5, (FOCIS-5), TIA-604-10 (FOCIS-10), RoHS 2002/95/EC compliant, supports IEEE802.3 and ANSI T11.2 (Fiber Channel)
Type
Fiber Cassette
Package Dimensions (L x W x H)
9.9 IN x 13 IN x 1.3 IN
Package Weight (Imperial)
0.81 lbs
FlexCore Front Access ODF Fiber Optic Splice Cassette, Multimode (OM4) 24-fiber LC Duplex to Discrete Pigtails, Ultra IL

FDSZA-24-10P

FlexCore Front Access ODF Fiber Optic Splice Cassette, Multimode (OM4) 24-fiber LC Duplex to Discrete Pigtails, Ultra IL
FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Universal, Standard IL, Left Hand Orientation

FDC9N-24-10ULH

FlexCore Front Access ODF Fiber Optic Cassette, Singlemode (OS2) 24-fiber LC Duplex to 2xMPO-12, Universal, Standard IL, Left Hand Orientation
FlexCore Front Access ODF Fiber Optic Splice Cassette, Multimode (OM4) 24-fiber LC Duplex to Ribbon Pigtails, Ultra IL

FDSZA-24-10R

FlexCore Front Access ODF Fiber Optic Splice Cassette, Multimode (OM4) 24-fiber LC Duplex to Ribbon Pigtails, Ultra IL
FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM5) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation

FDCWA-24-10ULH

FlexCore Front Access ODF Fiber Optic Cassette, Multimode (OM5) 24-fiber LC Duplex to 2xMPO-12, Universal, Ultra IL, Left Hand Orientation
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC/APC Cassette, Right side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters

F9UYBZRNNSNM015

OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC/APC Cassette, Right side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters
FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL

FDS9N-24-LAP

FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL
FlexCore Front Access ODF Fiber Optic Splice Cassette, Signature Core (OM4+) 24-fiber LC Duplex to Discrete Pigtails, Ultra IL

FDSSA-24-10P

FlexCore Front Access ODF Fiber Optic Splice Cassette, Signature Core (OM4+) 24-fiber LC Duplex to Discrete Pigtails, Ultra IL
OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters

F9UYBXRNNSNM015

OS2 Single Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Standard Insertion Loss, No pulling Eye - 15 Meters

Frequently Asked Questions

What are the connector types on the FDCZA-24-10ULH cassette?

The FDCZA-24-10ULH cassette features LC Duplex connectors on one side and 2 MPO12 connectors on the other.

Is the FDCZA-24-10ULH cassette left-handed or right-handed?

The FDCZA-24-10ULH cassette is a left-hand configuration.

What polarity method does the FDCZA-24-10ULH cassette use?

The FDCZA-24-10ULH cassette uses Universal Polarity.

What is the insertion loss performance of FDCZA-24-10ULH?

The FDCZA-24-10ULH cassette offers ULTRA IL (Ultra Insertion Loss) performance.

What fiber type does the FDCZA-24-10ULH cassette use?

The FDCZA-24-10ULH cassette uses OM4 fiber type.

How many fibers does the FDCZA-24-10ULH cassette support?

The FDCZA-24-10ULH cassette supports 24 fibers.

What type of cassette is FDCZA-24-10ULH?

It is a FlexCore MPO-LC Cassette, designed for connecting LC Duplex to 2 MPO12 connectors.

How many fibers does the FDCZA-24-10ULH cassette support?

The FDCZA-24-10ULH cassette supports 24 fibers.

What type of cassette is FDCZA-24-10ULH?

It is a FlexCore MPO-LC Cassette, designed for connecting LC Duplex to 2 MPO12 connectors.

What fiber type does the FDCZA-24-10ULH cassette use?

The FDCZA-24-10ULH cassette uses OM4 fiber type.

How to Install the FlexCore 4RU Universal Enclosure

This guide provides step-by-step instructions for installing the FlexCore 4RU Universal Enclosure, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Phillips head screwdriver, Wire strippers, Multimeter

Supplies needed:

#10-32 X 1/4” screws, #12-24 X 1/2” screws, Pan Ty cable ties, Fiber caution label, Laser warning label

  1. Remove the shipping bracket

    Unscrew the Phillips head screws on the top and bottom of the enclosure to remove the shipping bracket.

  2. Mount the enclosure

    Secure the enclosure to the rack using a minimum of four #10-32 X 1/4” screws. If RU space is open above, pre-install two screws on each side to assist in mounting.

  3. Install the cassettes

    Open the enclosure door, slide the tray out to the second stop position, and install the cassettes by lifting them from the front and securing them in place.

  4. Connect patch cords

    Install patch cords into the front of the cassettes from left to right, ensuring to route cables upward to the corresponding spool.

  5. Label the enclosure

    Apply the provided labels to the tray surfaces and the front door of the enclosure for identification according to EIA606-B standards.

  6. Verify installation

    Check all connections and ensure the enclosure is securely mounted and all components are properly installed before closing the door.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.