
Contact for Pricing
Minimum Qty: 2
Multiplier: 2
*Contact for lower quantities*
Overview
- Hub size: 3/4 inch NPT for standard conduit compatibility
- Range-taking design fits jacketed cables from 0.600 to 0.985 inch outer diameter
- Removable armour stops simplify cable termination and reduce installation time
- Aluminum jacketed construction resists corrosion in harsh industrial environments
- Compatible with Type MC, TC, and SNM cables for hazardous locations
Specifications
Application | For Hazardous Locations |
Color | Red;Silver |
Material | Aluminum |
Series | STAR TECK EXTREME XP |
Size | 3/4 Inch |
Standard | UL E82038, CSA 23086 |
Type | Teck Cable Fittings |
Package Dimensions (L x W x H) | 0.05 IN x 0.05 IN x 0.03 IN |
Package Dimensions (L x W x H) | 0.127 cm x 0.127 cm x 0.0762 cm |
Package Weight (Imperial) | 0.3900 L |
Package Weight (Metric) | 0.1770 kg |

GUAL36SA-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAL Type - L Shape, Pipe Size 1 Inch/27 Metric, Box is Aluminum, Cover is Die Cast Aluminum, Cover Opening 3.00 Inch/76.20 Millimeters, Gray
GUAL47-TB
1-1/4 Inch GUAL Hazardous Location Conduit Outlet Box, Box Ductile Iron Zinc Plated, Cover Die Cast Aluminum, 30 Cubic Inch
GUAL24SA-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAL Type - L Shape, Pipe Size 3/4 Inch/21 Metric, Box is Aluminum, Cover is Die Cast Aluminum, Cover Opening 2.00 Inch/50.80 Millimeters, Gray
GUAD36-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAD Type - T Shape, Pipe Size 1 Inch/27 Metric, Box is Ductile Iron with Zinc Plating, Cover is Die Cast Aluminum, Cover Opening 3.00 Inch/76.20 Millimeters, Gray
GUAL69-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAL Type - L Shape, Pipe Size 2 Inch/53 Metric, Box is Ductile Iron with Zinc Plating, Cover is Die Cast Aluminum, Cover Opening 5.00 Inch/127.00 Millimeters, Gray
GUAM69-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAM Type, Pipe Size 2 Inch/53 Metric, Box is Ductile Iron with Zinc Plating, Cover is Die Cast Aluminum, Cover Opening 5.00 Inch/127.00 Millimeters, Gray
GUAN47-G
PVC Double-Coated Conduit Outlet Box for Hazardous Locations, GUAN Type - L Shape, Pipe Size 1-1/4 Inch/35 Metric, Box is Ductile Iron with Zinc Plating, Cover is Die Cast Aluminum, Cover Opening 3.63 Inch/92.20 Millimeters, GrayFrequently Asked Questions
What is the hub size of the STEX075 fitting?
The fitting features a 3/4-inch NPT hub size for standard conduit connections.
What is the jacket diameter range for STEX075?
The fitting accommodates jacketed cables with outer diameters between 0.600 and 0.985 inches.
What cable types are compatible with STEX075?
The fitting is designed for Type MC, TC, and SNM jacketed cables commonly used in hazardous locations.
Does the STEX075 fitting require special tools for installation?
No, the fitting is designed for tool-free installation in most cases, reducing setup time.
Is the STEX075 fitting suitable for outdoor hazardous locations?
Yes, the aluminum jacketed construction provides corrosion resistance for outdoor and harsh environments.
How to Install STEX300 Cable Fittings with Liquid Sealant
Comprehensive guide for installing STEX300 Star Teck™ extreme cable fittings, including cable preparation, gland nut tightening, and application of SC4-KIT-1 liquid sealing compound for hazardous locations. Ensure all circuits are de-energized before starting.
Estimated time: 4h 10m
Tools needed:
Hacksaw, Wrench (for gland nut), Damp cloth, Gloves
Supplies needed:
STEX300 Cable Fitting, Cable (compatible with STEX300), SC4-KIT-1 Liquid Sealing Compound, Fiber Damming Material
- De-energize Circuits
WARNING: Risk of electrical shock. Before beginning installation or maintenance, verify that all circuits are de-energized to prevent electrical shock. This product must be installed by a qualified electrician in accordance with national and local electrical codes.
- Prepare Cable Working Length
Determine the required working length of conductors inside the enclosure or device. Remove a portion of the cable's outer jacket to expose the armor, then cut the armor using a hacksaw. CAUTION: Do not nick or cut the conductor insulation during this process.
- Trim Outer Jacket and Check Armor Stop
Trim the outer jacket to expose the armor strip length as indicated in the product table for your specific STEX300 fitting. Test the inner conductor bundle by inserting the conductor ends into the armor stop opening. If the inner conductor bundle will not pass through, unscrew and discard the Armor Stop.
- Feed Cable and Tighten Gland Nut
Feed the prepared cable through the gland nut opening and push until the cable armor hits the Armor Stop (if present). Tighten the gland nut until you obtain an appropriate seal or to the maximum torque specified in the table (e.g., 1600 in-lbs for STEX300). Ensure the bushing and collar ring seal evenly around the cable’s outer jacket and are flush with the gland nut face, keeping the cable centered for an optimal seal.
- Disassemble Fitting and Trim Inner Jacket
Disassemble the hub from the body sub-assembly by loosening the union. Unscrew the sealing chamber from the body sub-assembly. If the removable armor stop was not removed in Step 3, unscrew and discard it now. Trim the inner jacket to a length of 1/8”-3/8” to expose the conductor bundle. (For shielded data cables, refer to Section 2 of the original document for additional preparation steps).
- Prepare and Apply Liquid Sealing Compound (SC4-KIT-1)
CAUTION: For hazardous locations, this fitting must be assembled with SC4-KIT-1 LIQUID SEALANT. Pack the fiber damming material tightly into all voids between conductors and the body, spreading strands of uninsulated grounding conductor where applicable. Screw the sealing chamber back onto the body sub-assembly until it completely seats. Position the cable/fitting into a vertical position. Mix the SC4-KIT-1 sealing compound following its package instructions. For STEX300 fittings, fill approximately HALF of the sealing chamber, wait 2 hours, then fill the rest of the sealing chamber to the top. CAUTION: Remove all excess compound material from outside of the sealing chamber with a damp cloth. Do not use abrasive cleaners that may damage the flame path.
- Mount Hub and Secure Assembly
Mount the hub in the desired location. When the sealing compound is solidified (after approximately 1 hour from the final fill), place the encapsulated assembly into the hub and secure it in position by tightening the union until it bottoms (metal to metal contact).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.
