ABB Installation Products SLK 22 M Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line…
UPC: 783786752355
Documents & Media
Contact for Pricing
Minimum Qty: 25
Multiplier: 25
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- In-line variable-range mechanical fuse and disconnect kit
- Designed for street and highway lighting applications
- Accommodates conductor range: stranded 2-14 AWG, solid 2-14 AWG
- Maximum fuse rating: 30 Amps
- Flood-Seal design for outdoor durability
Specifications
Application | Rated 600 Volts, 30 Amps Maximum, perfect for heavy-duty applications |
Conductor Range | #2 to #14 STR/SOL AWG |
Connection | Mechanical |
Current Rating | 30 A |
Insulation | True |
Material | EPDM-Rubber Housing |
Number of Conductors | 2 |
Special Features | EPDM Rubber housing ensures a fully insulated, watertight and submersible connection. Safe separations - fuse or connecting link stays in load side when separated. Dual-rated and approved for a wide range of Aluminum or Copper Conductors |
Type | Breakaway Street Light Kit Fused |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.2400 L |
Package Weight (Metric) | 0.1090 kg |

SDK 22 M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, non-fused, conductor range stranded 2-14, and solid 2-14
SLT 2
Copper Flood-Seal Street and Highway Lighting Compression Fuse Kits - In-Line, Twin Housing, wire size stranded 2
SLK 22-60 M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, fused, conductor range stranded 2-14, and solid 2-14, Designed for 60 Amp Maximum Fuse.
SLK 6
Copper Flood-Seal Street and Highway Lighting Compression Fuse Kits - In-Line, Single Housing, wire size stranded 14-6 and solid 14-4
SLT-M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits-In-Line, fused, twin housing ,conductor range stranded 12,10,8,6,4 and solid 12,10,8,6,4
SLT 6
Copper Flood-Seal Street and Highway Lighting Compression Fuse Kits - In-Line, Twin Housing, wire size stranded 14-6 and solid 14-4
USK 2/0
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 14-2/0 connector length 1-1/2 inch, slotted screw, screws per side 1
USK 350-12 DS
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 12 inch, screws per side 2How to Install Flood-Seal Street Light Fuse/Link Kits (SLK/SDK Series)
A step-by-step guide for installing Thomas & Betts Flood-Seal Street Light Fuse Kits (SLK) or Link Kits (SDK), including cable preparation, assembly, and final connection for 600-volt copper and aluminum conductors.
Estimated time: 45m
Tools needed:
Torque wrench (25 in-lbs), Wire strippers, Utility knife
Supplies needed:
SLK or SDK Kit, Appropriate 13/32 inch cartridge fuse (max 600V, for SLK kits), Connecting link (for SDK kits), Copper or Aluminum Conductors (600V rated)
- Ensure Safety and De-energize
Identify line- and load- side wires and match the housing body parts before installing. Ensure all associated wires and the working area are de-energized. Installation must be performed by trained installers in accordance with all applicable local, state, and national electrical codes, installation standards, and safety rules to prevent danger of electric shock.
- Prepare Conductors
Strip 3/4 inch of insulation from the end of both the line-side and load-side conductors, baring the conductor.
- Prepare Line-End Housing and Cable
Select the correct cut-off ring on the line-end housing for the cable being used. Cut off the end housing at the tip of the arrow, leaving the correct cable size showing. Wipe the cable clean and pencil the end of the cable insulation for ease of installation. Apply silicone grease to the end of the cable and to the cut opening of the line-end housing. DO NOT grease the sealing rings on the line-end.
- Insert Cable and Torque Line-End
Insert the prepared line-side cable into the line-end housing until it extends 2 to 3 inches beyond the housing. Insert the cable into the line-end assembly and torque the set screw to 25 in-lbs.
- Prepare Load-End Housing and Cable, Insert Fuse/Link
Repeat the preparation steps for the load-end housing and cable: select and cut the correct ring, wipe the cable, pencil the insulation, and apply silicone grease to the cable end and cut opening. Insert the prepared load-side cable into the load-end housing until it extends 2 to 3 inches beyond the housing. Insert the cable into the load-end assembly and torque the set screw to 25 in-lbs. For SLK kits, insert the appropriate 13/32 inch (max 600 Volt) cartridge fuse (DO NOT use glass body fuse) into the load-end assembly. For SDK kits, insert the connecting link. Grease the sealing area of the load-end.
- Seal Both Ends with Rockets
Mate a Flood-Seal Rocket to the line-end assembly for a watertight seal. Repeat this process, mating the second Flood-Seal Rocket to the load-end assembly for a watertight seal.
- Make Final Electrical Connection
Mate the sealed line-end housing to the sealed load-end housing to complete the electrical connection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.