ABB Installation Products SLK 22-60 M Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line…
UPC: 783786752379
Documents & Media
Contact for Pricing
Minimum Qty: 75
Multiplier: 75
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for street and highway lighting applications
- In-line variable-range mechanical fuse and disconnect functionality
- Supports conductor range of 2-14 AWG (stranded and solid)
- Rated for a maximum fuse capacity of 60 Amps
- Flood-Seal design for outdoor environmental protection
Specifications
Application | Rated 600 Volts, 60 Amps Maximum, perfect for Heavy duty applications |
Conductor Range | #2 to #14 STR/SOL AWG |
Connection | Mechanical |
Insulation | True |
Material | EPDM-Rubber Housing |
Number of Conductors | 2 |
Special Features | EPDM Rubber housing ensures a fully insulated, watertight and submersible connection. Safe separations - fuse or connecting link stays in load side when separated. Dual-rated and approved for a wide range of Aluminum or Copper Conductors |
Type | Breakaway Street Light Kit Fused |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.2400 L |
Package Weight (Metric) | 0.1090 kg |

SDK 22 M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits, In-Line Variable-Range, non-fused, conductor range stranded 2-14, and solid 2-14
SLK 6
Copper Flood-Seal Street and Highway Lighting Compression Fuse Kits - In-Line, Single Housing, wire size stranded 14-6 and solid 14-4
SLT-M
Flood-Seal Street and Highway Lighting Mechanical Fuse and Disconnect Kits-In-Line, fused, twin housing ,conductor range stranded 12,10,8,6,4 and solid 12,10,8,6,4
SLT 6
Copper Flood-Seal Street and Highway Lighting Compression Fuse Kits - In-Line, Twin Housing, wire size stranded 14-6 and solid 14-4
USK 2/0
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 14-2/0 connector length 1-1/2 inch, slotted screw, screws per side 1
USK 350-12 DS
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 12 inch, screws per side 2
USK 350
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 2-9/16 inch, screws per side 1
USK 350-12
Aluminum Flood-Seal Mechanical Splice Two-Wire Kits, conductor range 6-350 connector length 12 inch, screws per side 1How to Install Flood-Seal Street Light Fuse Kits (SLK 22-60 M)
This guide provides step-by-step instructions for the safe and correct installation of Thomas & Betts Flood-Seal Street Light Fuse Kits, including cable preparation, fuse insertion, and final assembly for a watertight electrical connection.
Estimated time: 45m
Tools needed:
Torque wrench (25 in-lbs), Wire strippers, Utility knife or cable cutting tool
Supplies needed:
SLK 22-60 M Kit, 60 Amp, 13/32 inch (max. 600 Volt) cartridge fuse
- Prepare for Installation and Ensure Safety
Before beginning, identify the line- and load-side wires and match them with the correct housing body parts. Crucially, ensure all associated wires and the working area are completely de-energized to prevent electric shock. Installation must be performed by trained installers in accordance with all applicable local, state and national electrical codes, installation standards and safety rules.
- Prepare the Cable Ends (Line and Load)
For both the line-end and load-end cables, strip 3/4 inches of insulation from the conductor. Select the correct cut-off ring on the housing that matches your cable size and cut off the end housing at the tip of the arrow, leaving only the correct cable size visible. Wipe the cable clean, then pencil the end of the cable insulation for easier installation. Apply silicone grease to the end of the cable and to the cut opening of the housing.
- Insert and Secure Cables into Assemblies
Insert the prepared cable into its respective line-end or load-end assembly until it extends 2 to 3 inches beyond the housing. Once inserted, torque the set screw to 25 in-lbs to secure the cable firmly in place. Repeat this process for both the line-end and load-end cables and their corresponding assemblies.
- Install the Fuse in the Load-End Assembly
For the SLK 22-60 M kit, insert an appropriate 60 Amp, 13/32 inch (maximum 600 Volt) cartridge fuse into the load-end assembly. Do NOT use a glass body fuse. Apply silicone grease to the sealing area of the load-end assembly. Do NOT grease the sealing rings on the line-end assembly.
- Mate the Rocket to the Line-End Assembly
Take one of the FSS 20 'Flood-Seal'® Rockets and mate it securely to the line-end assembly. Ensure a tight fit to create a watertight seal, protecting the electrical connection from moisture.
- Connect the Line-End and Load-End Housings
Carefully mate the line-end housing (with the rocket attached) to the load-end housing (containing the fuse). Ensure the housings are fully engaged to establish the electrical connection and complete the watertight seal for the entire fuse kit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.