ABB Installation Products R2T35M4N0350 Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38…
UPC: 783786055579
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV outdoor termination for medium-voltage cable applications
- Supports cable insulation diameters from 0.84 to 1.38 inches
- Compatible with tape shield, wire shield, and unshielded cables
- Aluminum 2-hole spade connector for #2 AWG to 1250 kcmil conductors
- Eight sheds with 16.8in (427mm) minimum strike distance for 35kV service
Specifications
Application | Cable Termination, Outdoor Application, 35kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 650 to 750 kcmil |
Connection Type | 2-Hole Spade connector |
Current Rating | 1250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.84-1.38 inches (insulation diameter) |
Size | 0.84 - 1.38 inches |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T28M4-N0350
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
R2T35M4N0330
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
R2T15J2-N0330
Ranger2 Termination for 15KV indoor application, cable insulation diameter .64-1.12 for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade
R2T15J2-N0330-B2
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 500 /Compact or Solid 600. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)
R2T28J2-T1240
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed 1/0 /Compact or Solid 2/0
R2T15J2-T0270
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead
R2T15J4-N0380
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 750 kcmil Stranded or 900 kcmil Solid
R2T15J2-T0240
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 1/0/ Compact or Solid 2/0.Frequently Asked Questions
What cable insulation diameters does this termination support?
The termination supports cable insulation diameters ranging from 0.84 to 1.38 inches.
What types of cables are compatible with this termination?
The termination is compatible with tape shielded, wire shielded, and unshielded cables.
Is this termination suitable for outdoor applications?
Yes, the Ranger2 Termination is designed for 35KV outdoor applications.
What conductor sizes are supported by the included connector?
The connector supports conductor sizes from #2 to 1250 kcmil, including stranded or compressed 650 kcmil and compact or solid 750 kcmil.
What connector type is included with this termination?
The termination includes an aluminum 2-hole spade connector.
How to Install the 35kV Ranger 2 Shrink Fit Silicone Rubber Termination on Tape Shielded Cables
This guide provides step-by-step instructions for installing the 35kV Ranger 2 Shrink Fit Silicone Rubber Termination (R2T35M) on tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination application. Ensure all apparatus is de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire strippers or cable knife, Measuring tape or ruler, Solvent saturated pads, Aluminum oxide abrasive (grit 120 or finer)
Supplies needed:
Silicone Rubber Termination Halves, Lubricant (Silicone grease), Gray Silicone Rubber Electrical Tape, Constant Force Spring, Preformed Ground Braid, Sealing Mastic, Copper Foil Tape, Gloves, Terminal Lug or Connector, Vinyl Tape, Approved solvent
- Prepare the Cable
DANGER: Ensure all apparatus is de-energized during installation. Check cable size against the termination selection chart. Train the cable into position and cut to the required length. Prepare the cable by removing the jacket (13-1/2"/340mm), allowing for 2" (50mm) depth of terminal lug plus growth allowance. Hold down the tape shield edge with a single wrap of the supplied copper foil tape. Provide additional exposed conductor distance for aluminum lugs (1/4" to 3/4" depending on Kcmil).
- Install the Ground Braid
Wrap one band of mastic (50% stretch) around the cable jacket 1/4" (6mm) from the jacket end, cutting flush. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield once, trim excess, and secure with the constant force spring, wrapping in the same direction and cinching it tight. Secure the spring with two wraps of vinyl tape.
- Install the Lug or Connector
Check that the termination assembly fits over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector/lug and crimp according to the manufacturer's directions, avoiding crimping the last 3/8" to 1/2" of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-con insulation shield. If abrasive is necessary, use it only on the insulation (do not use abrasive on the semi-con insulation shield) and use aluminum oxide abrasive, grit 120 or finer. Be careful not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Halves
Create a track-resistant moisture seal between the termination insulator and lug/connector using gray silicone rubber electrical tape around the base of the terminal lug (max 2 layers if barrel diameter is equal to or greater than cable primary insulation, or build up to insulation diameter if smaller). Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step. For the lower termination with a fold-down skirt, pull the loose end of the removable core through the top until flush with the bottom. Slide the termination body onto the cable, align with the mastic seal, and carefully remove the core by unwinding counter-clockwise. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal.
- Complete Termination Installation and Grounding
Using the second housing, carefully pull the core down within 1 coil of the bottom. Slide the termination over the cable and carefully pull the core counter-clockwise, overlapping the first termination by 1-1/2" (40mm). Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal with the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1" and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Confirm that the High-K step does not exceed 1.5".
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.