ABB - Installation Products R2T28J2-N0330-B3 - Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

ABB Installation Products R2T28J2-N0330-B3 Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84…

UPC: 783786850297


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T28J2-N0330-B3) is engineered for robust 25/28KV outdoor power distribution applications. This termination is specifically designed to accommodate cable insulation diameters ranging from 0.84 to 1.38 inches, making it suitable for both Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cable types. Included with this termination is a high-quality Aluminum 2-Hole Spade connector. This connector is versatile, supporting a wide range of conductor sizes from #2 AWG up to 1250 kcmil. It is compatible with stranded or compressed conductors up to 500 kcmil, as well as solid conductors up to 600 kcmil. For secure and reliable mounting, the Ranger2 Termination features a durable Stainless Steel Mounting Bracket. This bracket is adjustable, accommodating mounting hole spacings between 1.45 and 1.95 inches, ensuring a secure fit in various installation scenarios. The UNSPSC code for this product is 26121648. Trust ABB Installation Products for dependable outdoor power termination solutions.
  • Designed for 25/28KV outdoor power applications
  • Accommodates cable insulation diameters from 0.84 to 1.38 inches
  • Compatible with Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cable
  • Includes Aluminum 2-Hole Spade connector for #2 AWG - 1250 kcmil conductors
  • Features a Stainless Steel Mounting Bracket for secure installation

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
500 to 600 kcmil
Connection Type
2-Hole Spade connector
Current Rating
1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Stainless Steel
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Mounting Bracket (1.45 inch - 1.95 inch)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84 - 1.38 inches (cable insulation diameter)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Voltage Rating
25/28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J4-N0330-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0 /Compact or Solid 2/0

R2T28J2-N0240

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1/0 /Compact or Solid 2/0
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28M2-N0310-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 400 /Compact or Solid 500, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250

R2T28J2-N0270

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 4/0 /Compact or Solid 250
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900

R2T28J4-N0380

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 750 /Compact or Solid 900
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 2/0 /Compact or Solid 3/0

R2T28J2-T0250

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 2/0 /Compact or Solid 3/0
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 /Compact or Solid 250.

R2T15J2-N0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable. Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 4/0 /Compact or Solid 250.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 350 /Compact or Solid 400. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

R2T15J2-N0300-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 350 /Compact or Solid 400. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

Frequently Asked Questions

What cable insulation diameters does this termination support?

This ABB Ranger2 Termination supports cable insulation diameters ranging from 0.84 to 1.38 inches.

What types of neutral cables are compatible with this termination?

This termination is compatible with both Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cable types.

What is the conductor size range for the included spade connector?

The included Aluminum 2-Hole Spade connector supports conductor sizes from #2 AWG up to 1250 kcmil.

What are the conductor type specifications for the spade connector?

The spade connector is suitable for stranded or compressed conductors up to 500 kcmil, and solid conductors up to 600 kcmil.

What are the dimensions for the stainless steel mounting bracket?

The stainless steel mounting bracket is designed for mounting hole spacings between 1.45 and 1.95 inches.

How to Install the R2T28J2 Ranger 2 Cable Termination

This guide provides step-by-step instructions for installing the R2T28J2 Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications, including cable preparation, lug installation, and termination sealing. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, optional)

Supplies needed:

Silicone Rubber Termination kit (including lubricant, grey silicone rubber tape, sealing mastic, gloves), Elastimold copper or aluminum lug/connector, Vinyl tape or binding wire, Silicone grease

  1. Prepare for Installation and Verify Components

    DANGER: All apparatus must be de-energized during installation. Inspect all kit contents for completeness and damage. Verify that all components, including the termination and chosen lug/connector, are compatible with your cable size and mating products. Read the entire installation instructions thoroughly before beginning and ensure all required tools and supplies are at hand. Maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Confirm the cable size fits within the kit's specified range. Train the cable into its final position and cut it to the required length, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable according to the dimensions provided in Table 1 and Figure 1, allowing for the depth of the terminal lug and additional conductor distance for aluminum lug growth (e.g., 1/4" for #2-350 Kcmil, 1/2" for 400-650 Kcmil, 3/4" for 750-1000 Kcmil). Wrap one band of sealing mastic around the cable jacket 1/4" (6mm) from the jacket end, using a 50% stretch. Position it carefully as it serves as a marker, and cut it flush without overlap. Bend the neutral wires back over the mastic and press them in, then secure them to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, using a 50% stretch and cutting it flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4" (6mm) dimension.

  3. Install the Lug or Connector

    If using a lug that will not fit through the termination core (e.g., non-Elastimold), clean the cable insulation and slide the termination body onto the cable *before* installing the lug; do not remove the core at this stage. Position the chosen connector or lug and crimp it according to its specific directions, ensuring not to crimp the last 1/4" to 3/8" of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, and never on the semi-con insulation shield. Be extremely careful not to reduce the cable insulation diameter below the minimum allowed by the kit specifications.

  5. Install the Termination Body

    Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape (from the kit) around the base of the terminal lug. If the lug barrel diameter is equal to or greater than the cable primary insulation, apply no more than two layers. If the barrel diameter is smaller, use the tape to build up the band to equal the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  6. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and the mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5".

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.