ABB - Installation Products R2T15J2-N0300-B2 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed 350 /Compact or Solid 400. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

ABB Installation Products R2T15J2-N0300-B2 Ranger2 Termination for 15KV outdoor application, cable insulation diameter .84-1.38…

UPC: 783786855599


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T15J2-N0300-B2, is engineered for reliable 15 kV outdoor applications. This termination system is specifically designed for Concentric Neutral and Jacketed Concentric Neutral cables, accommodating an insulation diameter range of 0.84 to 1.38 inches. The robust construction features an aluminum 2-hole spade connector, compatible with conductors from #2 AWG up to 1250 kcmil. This includes stranded or compressed conductors ranging from 350 kcmil to 400 kcmil, as well as compact or solid 400 kcmil conductors. The Ranger2 termination system ensures secure and durable connections essential for outdoor power distribution. The included plated mild steel mounting bracket provides a stable and compliant mounting solution, adjustable for pipe sizes between 1.10 inches and 1.50 inches (28-38mm). This precise fit minimizes movement and stress on the cable termination, contributing to long-term operational integrity. Key specifications include: * **Voltage Rating:** 15 kV * **Cable Insulation Diameter:** 0.84 - 1.38 inches * **Conductor Size:** #2 AWG - 1250 kcmil (Aluminum 2-hole spade) * **Conductor Types Supported:** Stranded/Compressed 350 kcmil, Compact/Solid 400 kcmil * **Mounting Bracket:** Plated Mild Steel, adjustable 1.10 - 1.50 inches (28-38mm) * **Manufacturer:** ABB - Installation Products * **Series:** Ranger2 This Ranger2 termination is a critical component for maintaining the integrity of outdoor electrical infrastructure, ensuring safe and efficient power delivery in demanding environments. Its design prioritizes secure connections and ease of installation for specific cable types and sizes.
  • 15 kV voltage rating for outdoor power applications.
  • Accommodates cable insulation diameters from 0.84 to 1.38 inches.
  • Aluminum 2-hole spade connector for #2 AWG to 1250 kcmil conductors.
  • Supports stranded/compressed 350 kcmil and compact/solid 400 kcmil conductors.
  • Includes plated mild steel mounting bracket adjustable for 1.10-1.50 inch pipe.

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
350 to 400 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.

R2T15J1-N0300

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid

R2T15J1-T1240

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For AL Conductor only w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1.

R2T15J1-T1220

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum Barrel For Aluminum Conductor only with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)

R2T15J1-T0230-B1

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 2/0 /Compact or Solid 3/0. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)

R2T15J1-T0250-B2

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 2/0 /Compact or Solid 3/0. Plated Mild Steel Mounting Bracket 1.10 inch - 1.50 inch (28-38mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)

R2T15J1-T0220-B1

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #2 /Compact or Solid #1. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0.

R2T15J1-T0230

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed #1 /Compact or Solid 1/0.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid

R2T15J1-T0240

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For AL or CU Conductor w/copper wire lead #2 to 4/0. 1/0 Stranded or 2/0 Solid

Frequently Asked Questions

What cable sizes does the R2T15 termination support?

The R2T15 termination supports cable insulation diameters from 0.64 inches to 2.10 inches, covering #2 AWG through 1250 kcmil.

What is the voltage rating of the R2T15 termination?

The R2T15 cable termination has a voltage rating of 15 kV.

What is the operating temperature range for the R2T15?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum altitude for R2T15 installation?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 meters).

What is the power system frequency range for R2T15?

The R2T15 termination is designed for power system frequencies ranging from 48 to 62 Hz.

Where can I find installation instructions for R2T15?

Installation instructions are IS-1134 for R2T15J, IS-1135 for R2T15M, and IS-1136 for R2T15L.

What is the maximum design voltage to ground for R2T15?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What cable types are compatible with the R2T15 units?

The R2T15 units accommodate popular XLP and EPR cable types and shield constructions.

How is the R2T15 cable termination mounted?

The R2T15 termination can be free hanging or mounted using an optional support bracket.

What is the purpose of insulating silicone sleeves?

Insulating silicone sleeves are available to provide more creepage or for wildlife protection to insulate the connectors.

How to Install R2T15/28J Ranger 2 Cable Termination

This guide provides step-by-step instructions for the installation of 15kV and 28kV Ranger 2 Cable Terminations, suitable for indoor/outdoor applications on concentric and jacketed concentric neutral cables. All apparatus must be de-energized during installation, and this product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed), Vinyl tape or binding wire, Gloves

Supplies needed:

Silicone Rubber Termination, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Terminal lug (copper or aluminum), Cable Support Bracket (optional)

  1. Prepare the Cable for Termination

    Check that the cable size fits within the kit's range as shown in the Termination Selection Chart. Train the cable into position and cut to the required length, allowing sufficient neutral wire for grounding connections. Prepare the cable using the dimensions provided in the kit's charts, accounting for terminal lug depth and additional exposed conductor distance for aluminum lugs. Apply one band of sealing mastic, stretched 50%, 1/4 inch (6mm) from the cable jacket end, cutting it flush without overlap. Bend neutral wires back over the mastic and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second 50% stretched mastic band over the neutral wires and the previously applied mastic, cutting it flush without overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  2. Install and Clean the Lug or Connector

    If your chosen lug will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable *before* installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to its specific directions, ensuring the last 1/4 to 3/8 inch of the connector remains uncrimped. After crimping, remove any excess oxide inhibitor and sharp crimp flashings. Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If abrasive must be used, apply only aluminum oxide abrasive (grit 120 or finer) on the insulation only, being careful not to reduce the cable insulation diameter below that allowed by the kit.

  3. Install the Termination Body

    Create a track-resistant moisture seal by wrapping a band of grey silicone rubber tape (contained in the kit) around the base of the terminal lug. If the barrel diameter is smaller than the cable primary insulation, use the tape strip to build up the tape band equal to the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is firmly butted against the leading edge of the mastic seal. Do not push or pull the termination assembly while removing the core material.

  4. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining grey silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.