Authorized ABB Distributor (Installation Products)
ABB - Installation Products K676LR-H5270 - 15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Bi-Metal Compression Lug, Conductor Size AWG 2/0 Stranded/Compressed or 3/0 Compact/Solid.

ABB Installation Products K676LR-H5270 15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud…

UPC: 075114424110


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K676LR-H5270 is a high-capacity deadbreak elbow connector designed for medium-voltage applications up to 25kV and 900A continuous current. This connector is engineered for reliable, maintenance-free operation in underground distribution systems, pad-mounted transformers, and switchgear installations. The deadbreak design allows for safe connection and disconnection under load without interrupting service, making it ideal for utility and industrial applications where operational continuity is critical. Key specifications include a bi-metal compression lug compatible with 2/0 stranded/compressed or 3/0 compact/solid conductors, ensuring broad compatibility with standard cable types. The cable insulation range of 0.850–1.050 inches accommodates common medium-voltage cable diameters, while the integrated test point enables safe voltage verification without service interruption. The included insulated plug, cap, stud, lug, and cable adapter provide a complete installation kit, reducing procurement complexity and ensuring proper component matching. This connector meets the demands of 15/25kV class systems, offering a robust solution for underground residential distribution (URD), commercial power distribution, and industrial substations. Its deadbreak design eliminates the need for load interruption during maintenance, reducing downtime and improving system reliability. The bi-metal construction ensures long-term corrosion resistance and mechanical integrity, even in harsh environmental conditions. Applications include connections to transformers, switchgear, and other medium-voltage equipment in utility networks, renewable energy installations, and industrial facilities. The K676LR-H5270 is part of ABB’s K676LR series, a trusted line of medium-voltage connectors known for durability and performance in critical infrastructure.
  • Voltage rating: 15/25 kV with 900A continuous current capacity
  • DeadBreak design allows safe connection/disconnection under load
  • Bi-metal compression lug fits 2/0 stranded/compressed or 3/0 compact/solid conductors
  • Cable insulation range: 0.850–1.050 inches
  • Includes insulated plug, cap, stud, lug, and cable adapter for complete installation

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and Equipment in a de-energized State. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655SR-F0240

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
35kV 600 Series Deadbreak Elbow without Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. 200ECS Cold-Shrinkable Jacket Seal Included.

755LR-K0250-S

35kV 600 Series Deadbreak Elbow without Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70. 200ECS Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0/ Compacted Solid 2/0.

K655RLR-G0240

600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0/ Compacted Solid 2/0.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. With Any Customer Specific Modifications - CS871 - CSA Compatibility.

K675LR-N-5400-CS871

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. With Any Customer Specific Modifications - CS871 - CSA Compatibility.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.

775LR-Q5440-S-CS1634

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.900 inch to 2.120 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 1250. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.

775LR-P5410-S-CS1634

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.725 inch to 1.935 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 1000. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.
900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.

775LR-M5330-S-CS1634

900 Amp, 35kV, 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size kcmil Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included. Factory lubricated receptacle interface and cable entrance of elbow or bushings extender.

Frequently Asked Questions

What voltage ratings does this connector support?

The connector supports 15kV and 25kV voltage ratings, making it suitable for medium-voltage applications.

What conductor sizes are compatible with this lug?

The bi-metal compression lug accommodates 2/0 stranded/compressed or 3/0 compact/solid conductors.

Does this elbow allow hot-line connections?

Yes, the deadbreak design enables safe connection and disconnection under load without interrupting service.

Is a test point included for voltage verification?

Yes, the elbow includes an integrated test point for safe voltage measurement without service interruption.

What materials are used in the lug construction?

The lug is constructed from bi-metal materials, ensuring corrosion resistance and mechanical strength.

Is this connector suitable for underground applications?

Yes, the deadbreak design and robust construction make it ideal for underground residential distribution (URD) systems.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing 655/675LR and K655/K675LR Deadbreak Elbow Connectors. These connectors provide fully shielded, submersible deadfront cable connections for 15kV and 25kV class high voltage systems.

Estimated time: 2h

Tools needed:

Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device (for capacitive test points), Torque wrench

Supplies needed:

655/675LR or K655/K675LR Elbow connector, Cable adapter, Compression lug, Insulating plug (if used), Lubricant (silicone type recommended), Threaded stud (if mating part not equipped), Wire (at least No. 14 AWG Copper for grounding), Suitable grounding connector, Tape marker

  1. De-energize Apparatus and Position Cable

    DANGER: Ensure all apparatus is de-energized before beginning installation. Assemble the cable in its final position with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  2. Prepare Cable Outer Surface and Layers

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Refer to the installation instructions (Step 3) for specific cable preparation, including removing the outer jacket (if applicable) and preparing the semi-con shield and cable insulation to the specified dimensions for your cable type (e.g., jacketed, non-jacketed, Unishield, lead sheath).

  3. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If not, redo the assembly.

  5. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8 inches. Crimp the compression lug according to the instructions supplied with the lug. Wipe off any excess inhibitor from the lug and cable adapter. After crimping, the distance from the end of the lug to the cable adapter must be between 6-3/8 inches and 7-1/8 inches (162mm-181mm). If not, redo the assembly.

  6. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  8. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite Mating Part (if applicable)

    If connecting to an opposite mating part, clean and lubricate its surface. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the specific instructions provided with that component.

  10. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down firmly until it snaps into place.

  11. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper equivalent) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions for any grounding device used, or employ an alternate grounding method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Perform Final Torque Check (for L-Kits)

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque as per the instructions provided with the L-Kit.

  13. Perform Voltage Test

    To determine if the circuit is energized, use a hotstick to remove the test point cap, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment; use a suitable sensing device designed for capacitive test points. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.