ABB Installation Products K656YSR-J0260 600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation…
UPC: 075114401708
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp current rating
- 15/25kV voltage class
- Deadbreak straight receptacle design
- Integrated test point for diagnostics
- Accommodates cable insulation diameters from .980" to 1.180"
- Aluminum compression lug for 3/0 AWG compressed stranded or 4/0 AWG compacted solid conductors
Specifications
Amperage Rating | 15 to 25 kV |
Application | 15/25kV, 600 Amps |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Conductor Size | AWG Compressed Stranded 3/0 or Compacted Solid 4/0 |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Aluminum |
Series | K656YSR |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Standard | ANSI/IEEE Standard 386 |
Type | Deadbreak Straight Receptacle with Test Point |
Voltage Rating | 15/25 kV |
Voltage Rating | 15 to |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656DLR-F0260
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
K656YSR-L0310
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 400 kcmil or Compacted Solid 450 kcmil.
K656YSR-M0360
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 650 kcmil or Compacted Solid 750/800 kcmil.
K656LR-K0380
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 750 Stranded/Compressed
K656DLR-N0410-S
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed Stranded 1000. Cold Shrinkable Jacket Seal.
656CETP-NAC04-DRG-S
15kV, 600 Amps, Combo T Elbow with Bus Stud, Cable Adapter and Lug. Cable Insulation Diameter 1.515-1.780 inches, Tin Plated Aluminum ShearBolt Lug, Conductor Size 750 to 1250 kcmil Stranded/Compressed and Solid/Compact. Cold Shrinkable Jacket Seal.
K656LR-N0410-CS871
25kV, 600 Amp, Deadbreak, Elbow with Test Point, (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter), No Sealing Kit, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. Any Customer Specific Modifications CS871 - CSA Die Compatibility.Frequently Asked Questions
What components are included in the K656YSR kit?
Each kit contains a straight receptacle housing, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, installation instructions, and bolts & washers.
Does the K656YSR-W0X include a test point?
Yes, the K656YSR-W0X features a non-corrosive capacitive test point.
Can the receptacle be connected or disconnected while energized?
No, the receptacle can only be easily connected or disconnected in a de-energized state for safety.
What is the continuous current rating of the receptacle?
The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.
What are the operating voltages for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.
What are the operating voltages for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.
What cable specifications are compatible with K656SR?
It is compatible with #2 AWG to 1250 kcmil aluminum and copper conductors. Cable insulation diameters should range from 0.640 inches to 1.935 inches.
What is the K656SR designed for?
The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings. It connects straight cables to switchgear or electrical apparatus with 600 Amp bushings.
What cable specifications are compatible with K656SR?
It is compatible with #2 AWG to 1250 kcmil aluminum and copper conductors. Cable insulation diameters should range from 0.640 inches to 1.935 inches.
What components are included in the K656YSR kit?
Each kit contains a straight receptacle housing, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, installation instructions, and bolts & washers.
How to Locate Installation Instructions for K656YSR-J0260
This guide explains how to find the proper installation instructions for K656YSR-J0260, as the provided document refers to external documentation for the actual installation steps.
Estimated time: 5m
- Understand Product Application
Recognize that the K656YSR-J0260 product is specifically designed for use with Elastimold separable joint housings. Its installation is dependent on these components.
- Locate Primary Installation Documentation
Identify and retrieve the dedicated installation instructions that are physically packaged with the Elastimold separable joint housings. These are the authoritative source for installation.
- Follow Manufacturer's Instructions
Adhere strictly to the installation instructions provided with the Elastimold separable joint housings. These instructions contain the complete and correct procedures for installing K656YSR-J0260 safely and effectively.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.