ABB - Installation Products K656SRH0270 - 600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or kcmil Solid 250 or mmSquared 126.67.

ABB Installation Products K656SRH0270 600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive…

UPC: 783786507634


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656SRH0270 is a 600 Amp DeadBreak straight receptacle engineered for 15/25kV medium-voltage applications. This high-performance component integrates a cable adapter, aluminum compression lug, and retaining ring to deliver secure, maintenance-free electrical connections in critical power distribution systems. The DeadBreak design enables safe connection and disconnection under load without interrupting service, making it ideal for utility, industrial, and commercial installations where operational continuity is essential. Key specifications include a voltage rating of 15/25kV and a current rating of 600A, ensuring compatibility with high-power systems. The receptacle accommodates cable insulation diameters from 0.850 to 1.050 inches, providing flexibility for various cable types. The included aluminum compression lug supports compressed stranded conductors up to 4/0 AWG or 250 kcmil, as well as solid conductors up to 250 kcmil (126.67 mm²), ensuring broad compatibility with standard industrial wiring practices. A capacitive testpoint is integrated into the design, enabling non-invasive voltage detection for enhanced safety and diagnostic capabilities during installation and maintenance. The DeadBreak configuration eliminates the need for load interruption when making or breaking connections, reducing downtime and improving system reliability. This product is part of ABB's Installation Products line, designed for use in demanding environments where durability and performance are critical. The K656SRH0270 is suitable for applications such as switchgear, motor control centers, and power distribution panels where high-current, medium-voltage connections are required. Its robust construction and precise engineering make it a reliable choice for engineers and contractors specifying components for critical infrastructure projects.
  • 600 Amp current rating for high-power applications
  • 15/25kV voltage rating for medium-voltage systems
  • DeadBreak design enables safe connection/disconnection under load
  • Includes aluminum compression lug for 4/0 AWG to 250 kcmil conductors
  • Capacitive testpoint for non-invasive voltage detection

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.

K656SRH0320

600 Amp Straight Receptacle with Cable Adapter, Lug and Retaining Ring, with capacitive testpoint, DeadBreak, 15/25KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.
600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K656I-LM0380

600 Amp, 15/25KV, Separable Straight Joint Package 2-Way with Test Point, Splice, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable Insulation Diameter .850-1.050 inches, Aluminum Lug, Conductor Size 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. No Sealing kit.

K656I-H0270

25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable Insulation Diameter .850-1.050 inches, Aluminum Lug, Conductor Size 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. No Sealing kit.
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K656CYL0300L0360L036

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150

K655YSR-H0290

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil

K655YSR-L0320

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 or Compacted Solid 800/900.

K656CH-M0380

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 or Compacted Solid 800/900.

Frequently Asked Questions

What is included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

Does the K656SR have a test point?

Yes, the K656SR includes a non-corrosive capacitive test point.

Can the receptacle be connected while energized?

No, the K656SR can only be easily connected or disconnected in a de-energized state for safety.

Does the product meet industry standards?

Yes, the K656SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating?

The continuous current rating for both 15kV and 28kV voltage classes is 600 Amps.

What are the operating voltage limits for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.

What conductor sizes are compatible with K656SR?

The K656SR product range supports #2 AWG to 1250 kcmil for aluminum and copper conductors. It accommodates insulation diameters from .640 in to 1.935 in.

What is the K656SR designed for?

The K656SR is designed for fully shielded, submersible cable connections on 15/25kV high-voltage apparatus bushings. It allows straight cable connections on switchgear or electrical apparatus with 600 Amp bushings.

What is included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

How to Install the K656SR/M656SR Straight Receptacle

This guide provides detailed instructions for installing the K656SR and M656SR straight receptacles, which enable an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings. Ensure all apparatus are de-energized during installation to prevent serious or fatal injury.

Estimated time: 2h

Tools needed:

5/8-11 tap (if applicable), Hex wrench (supplied), Torque wrench with 15/16 socket, Wire strippers, Crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire (or equivalent), Suitable connector (for neutral and grounding wires), Cable (to be connected)

  1. Prepare Apparatus Bushing

    DANGER: All apparatus must be de-energized during installation. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the bushing converter onto the apparatus bushing with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.

  2. Cut Cable End Squarely

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Manage Concentric Neutral Wires (If Applicable)

    If applicable, unwrap the concentric neutral wires a distance of 30 inches (76cm). DO NOT CUT them. Bend and fold them back out of the way.

  4. Clean Cable Outer Jacket

    Wipe the outer jacket clean for a distance of 38 inches (96.5cm) or up to the concentric neutral wires.

  5. Slide Receptacle Housing onto Cable

    Slide the receptacle housing onto the cable a distance of 30 inches (76cm).

  6. Prepare Cable Insulation and Install Cable Adapter

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) from cable end, 11-1/4” (28.58cm) for shield removal). Do not cut or nick the cable insulation. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  7. Expose Conductor to Correct Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. Verify the length of the exposed conductor is 4 3/4” – 5” (12.06cm–12.7cm). If the length is incorrect, redo the assembly from previous steps.

  8. Secure Holding Collar

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  9. Prepare and Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  10. Confirm Component Alignment

    Confirm that the receptacle housing, cable adapter, crimp connector, and contact adapter are oriented in the correct order as shown in the documentation. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  11. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If this distance is over 7” (17.8cm), do not proceed and redo all previous work.

  12. Assemble and Torque Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the assembly. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft.-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  13. Lubricate Adapters

    Generously apply the supplied lubricant or ELASTIMOLD approved lubricant to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product.

  14. Seat Receptacle Housing and Connect Ground

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, making a small loop and twisting tightly. Gather the concentric neutral wires and, using a suitable connector, connect them with the grounding wire.

  15. Install Hose Clamp (35kV Only)

    For 35kV installations only, position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.