ABB - Installation Products K656CH-M0380 - 600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 or Compacted Solid 800/900.

ABB Installation Products K656CH-M0380 600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation…

UPC: 783786093779


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656CH-M0380 is a 600 Amp, 15/25 kV separable H joint package designed for reliable electrical connections in medium voltage applications. This 4-way configuration includes a test point for enhanced system diagnostics and maintenance. Engineered to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches, it ensures a secure and precise fit for a variety of cable types. The package features an aluminum compression lug, providing robust conductivity and long-term performance. It is compatible with stranded conductors sized 700/750 kcmil or compacted solid conductors sized 800/900 kcmil. This component from ABB Installation Products is crucial for ensuring the integrity and safety of power distribution networks. Its design facilitates efficient cable termination and jointing, minimizing downtime and operational risks. The inclusion of a test point allows for non-intrusive testing of the circuit, further contributing to system reliability and proactive maintenance strategies. The K656CH-M0380 is built to meet the demanding requirements of industrial and utility power systems, offering a dependable solution for connecting and branching medium voltage cables.
  • 600 Amp current rating
  • 15/25 kV voltage class
  • 4-Way separable H joint configuration
  • Integrated test point for diagnostics
  • Aluminum compression lug for 700-900 kcmil conductors

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber. Includes Integral Capacitive Test Point. Reusable Components Reduce Inventory and other Costs
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable H-Joint Assembly
Voltage Rating
15 to 25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
34.0000 L
Package Weight (Metric)
15.4220 kg
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.

655CETPNM0380S

600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Solid 500/550. 200ECS-G2 Jacket Seal and Grounding Kit Included.

K655YSR-K0320-SG2

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Solid 500/550. 200ECS-G2 Jacket Seal and Grounding Kit Included.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compacted/Solid 900 kcmil.

K656CH-L0380

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compacted/Solid 900 kcmil.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 250 or Solid 300.

K655YSR-G0280

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 250 or Solid 300.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

K656CH-K0330-S

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.

K656CH-H0270-S

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150

K655YSR-J0290

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656CH-J0300

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

Frequently Asked Questions

What is the maximum cable insulation diameter supported?

The K656CH-M0380 supports cable insulation diameters ranging from 1.370 inch to 1.630 inch.

What conductor sizes are compatible with this H joint?

This H joint is compatible with compressed stranded conductors sized 700/750 kcmil or compacted solid conductors sized 800/900 kcmil.

What is the voltage rating of this ABB H joint?

The ABB K656CH-M0380 has a voltage rating of 15/25 kV.

What type of lug is included in this package?

The package includes an aluminum compression lug.

What is the current carrying capacity of this H joint?

The K656CH-M0380 has a current rating of 600 Amps.

How to Install K656CH Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of K656CH Deadbreak Receptacles, designed for splicing and tapping solid dielectric type cables rated for 600 ampere at 15kV and 25kV. It covers cable preparation, connector assembly, and grounding procedures for one leg of the connector.

Estimated time: 1h 45m

Tools needed:

Hex wrench, Torque wrench with 15/16" socket, Wire brush (for aluminum cable), Crimp tool, Cable cutting tool, Wire strippers, Rag, Approved safety solvent, Assembly tool (650ATY or 600RRT), Measuring tape/ruler

Supplies needed:

K656CH Deadbreak Receptacle (housing, cable adapter, center section, aluminum holding collar), Lubricant (supplied), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod (supplied), High voltage cable (concentric neutral or flat metallic tape shielded), ECS grounding device (optional), No. 14 AWG copper wire or equivalent, Electrical tape, Conductive copper strip (for flat metallic tape shielded cable)

  1. Prepare for Installation and Perform Safety Checks

    DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Check threads by threading a probe into the compression lug; if resistance is encountered, check for damage and replace the component. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable and Slide Initial Components

    Wipe the outer jacket of the cable clean for a distance of 38 inches (96.5 cm) from the end. Cut the cable end squarely to ensure maximum available length for crimp growth. If using an ECS grounding device, slide the tube onto the cable a distance of 38 inches (96.5 cm). Slide the receptacle housing onto the cable a distance of 30 inches (76.2 cm).

  3. Perform Cable Specific Preparation

    Refer to the special cable preparation supplement for your cable type. For Jacketed Concentric Neutral Cable: Measure 13-3/4 inches (34.9 cm) from the cable end and remove the jacket, taking care not to damage neutral wires. Bend neutral wires back. Measure 10-1/4 inches (26 cm) from the end and remove the semi-con shield with a straight, smooth cut. At 1 inch (2.5 cm) from the semi-con shield end, wrap two turns of tape as a marker. Bevel the insulation end at a 45-degree angle, approximately 1/4 inch (0.6 cm) back. Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end toward the outer jacket. Lubricate the cable sparingly and the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker. For Flat Metallic Tape Shielded Cable with Semi-con Shield: Measure 13-3/4 inches (34.9 cm) from the cable end and remove the outer jacket with a straight, smooth cut, taking care not to damage the tape shield. Measure 11-1/4 inches (28.6 cm) and remove the tape shield to that point. Wrap a conductive copper strip around the edge to secure the tape shield, then wrap two turns of tape over the end of the tape shield and copper strip, with the tape edge 11-1/4 inches (28.6 cm) from the outer jacket end. Measure 10-1/4 inches (26 cm) and remove the semi-con shield with a straight, smooth cut. Bevel the insulation end at a 45-degree angle, approximately 1/4 inch (0.6 cm) back. Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end toward the outer jacket. Lubricate the cable sparingly and the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker.

  4. Prepare Conductor and Assemble Retaining Ring

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length should be 4-3/4 to 5 inches (12.1 to 12.7 cm); if not, redo the assembly. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor measures 4-3/8 to 4-3/4 inches (11.1 to 12.1 cm); if not, redo the assembly.

  5. Install Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8 cm), do not proceed; redo all previous work. Repeat steps 4 and 5 for any remaining cables to be joined.

  6. Crimp Connectors

    Before crimping, confirm that all components are positioned correctly and that the bolt holes in the crimp connectors are aligned with the bolt holes of the mating part. Crimp the connectors following the instructions packaged with the connectors, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8 cm), do not proceed; redo all previous work.

  7. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the bolt. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. (67.8 to 81.3 Nm).

  8. Lubricate and Position Receptacle Housing

    Apply the supplied lubricant or an ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section as shown in the diagram, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface (as shown in the diagram). Insert the supplied nylon venting rod.

  9. Complete Receptacle Housing Assembly

    Attach the appropriate assembly tool (650ATY or 600RRT). If using the 650ATY tool, ensure the 'U' shaped yoke is over the splice section and the 'C' shaped yoke is over the receptacle housing. Slowly raise the handle to slide the receptacle housing over the splice section. If using the 600RRT tool, slide the receptacle housing over the interface by turning the hex nut on either end of the tool. WARNING: Do not place hands on the threaded rod or guide shaft with the assembly tool in place. Remove the venting rod once the housing is fully assembled. Repeat steps 8 and 9 for any remaining cables.

  10. Perform Final Checks and Grounding

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. If using an ECS grounding device, complete its installation according to its specific instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect it to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.