ABB - Installation Products K656I-H0270 - 25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable Insulation Diameter .850-1.050 inches, Aluminum Lug, Conductor Size 4/0 Stranded/Compressed AWG or 250 Solid/Compact kcmil. No Sealing kit.

ABB Installation Products K656I-H0270 25KV 600 Amp, Deadbreak, Separable Straight Joint Package (2-Way) with Test Point, Cable…

UPC: 783786640225


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products’ K656I-H0270 is a 25kV, 600A deadbreak separable straight joint package designed for reliable medium-voltage cable connections in underground distribution systems, industrial power networks, and utility substations. This 2-way joint accommodates cable insulation diameters from 0.850 to 1.050 inches and supports conductor sizes of 4/0 stranded/compressed AWG or 250 solid/compact kcmil. The package includes an integral capacitive test point for safe voltage verification without cable disconnection, enabling operational efficiency during maintenance or testing. Constructed with an aluminum lug for corrosion resistance and mechanical strength, the K656I-H0270 is optimized for applications requiring deadbreak operation. The deadbreak design allows for hot-stick operation, enabling safe connection and disconnection under load without power interruption. This product is part of ABB’s Installation Products line, known for compatibility with industry-standard separable connectors. Key features include a compact design suitable for small vaults and manholes, fully shielded and submersible construction with 100% peroxide-cured EPDM molded rubber, and reusable components that reduce inventory and operational costs. The joint meets ANSI/IEEE Standard 386 (latest revision) with ratings for 15kV and 25kV voltage classes, including 600A continuous current, 25kA symmetrical momentary rating, and impulse withstand up to 140kV BIL. The modular design supports future system circuit changes or expansions, and the product can also be used in direct-buried applications. Note: No sealing kit is included; ensure proper sealing materials are selected for environmental protection. For applications requiring additional environmental resistance, consult ABB’s accessory catalog for compatible sealing solutions.
  • 25kV/600A deadbreak separable straight joint with integral test point
  • Supports cable insulation diameters 0.850–1.050 inches and conductors 4/0 AWG or 250 kcmil
  • Fully shielded, submersible, and reusable with 100% peroxide-cured EPDM rubber
  • Compact design ideal for small vaults, manholes, and direct-buried applications
  • Meets ANSI/IEEE Standard 386 with 25kA momentary rating and 140kV BIL impulse withstand

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Deadbreak, Separable Straight Joint
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Poles
2-Way
Series
K656I
Size
0.850-1.050 inches (insulation diameter)
Size
Cable Insulation Diameter 0.850-1.050 inches
Special Features
Fully Shielded, Fully Submersible, 100 percent Peroxide cured Molded EODM Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Straight Joint
Voltage Rating
15 to 25 kV
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
16.0000 L
Package Weight (Metric)
7.2580 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

656ETP-H0270-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K656CYL0300L0360L036

600 Amp, 15/25KV, Separable Wye Joint Package, 3-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150

K655YSR-H0290

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 300 or Solid 350 or mmSquared 150
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil

K655YSR-L0320

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 450 kcmil or Compacted Solid 500/550 kcmil
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 or Compacted Solid 800/900.

K656CH-M0380

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 or Compacted Solid 800/900.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Solid 500/550. 200ECS-G2 Jacket Seal and Grounding Kit Included.

K655YSR-K0320-SG2

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Solid 500/550. 200ECS-G2 Jacket Seal and Grounding Kit Included.
600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compacted/Solid 900 kcmil.

K656CH-L0380

600 Amp, 15/25 kV, Separable H Joint package 4-Way with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed/Stranded 700/750 kcmil or Compacted/Solid 900 kcmil.

Frequently Asked Questions

What is the momentary current rating?

The momentary current rating for both 15kV and 25kV voltage classes is 25kA Sym for 10 cycles.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

What are the operating voltage limits for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What is the momentary current rating?

The momentary current rating for both 15kV and 25kV voltage classes is 25kA Sym for 10 cycles.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

What are the operating voltage limits for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What are the operating voltage limits for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

How to Install K656 Series Deadbreak Receptacles

This guide provides step-by-step instructions for installing K656 series deadbreak receptacles, designed to splice and tap solid dielectric cables rated for 600 amps at 15kV and 25kV. DANGER: Ensure all apparatus is de-energized and follow high-voltage safety practices to prevent serious injury or death.

Estimated time: 1h 30m

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), Crimp tool, 650ATY assembly tool (optional), 600RRT assembly tool (optional), Rag, Approved safety solvent

Supplies needed:

K656 Receptacle housings, Cable adapters, I, Wye, or H Center sections, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Electrical tape, No. 14 AWG copper wire or equivalent, ECS grounding device (if used), Conductive copper strip (for flat metallic tape shielded cable)

  1. Prepare for Installation and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Verify proper fit of all components with cable and/or mating products. Check threads by threading a probe into the compression lug; replace damaged components if resistance is encountered. Have all required tools ready and maintain cleanliness.

  2. Prepare Cable Jacket and Slide Components

    Wipe the outer jacket clean for a distance of 38 inches. Cut the cable end squarely to ensure maximum available length for crimp growth. If using an ECS grounding device, slide the tube onto the cable a distance of 38 inches. Slide the receptacle housing onto the cable a distance of 30 inches.

  3. Perform Cable Preparation (Jacketed Concentric Neutral Cable Example)

    NOTE: Refer to the special cable preparation supplement for your specific cable type (e.g., Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable). For Jacketed Concentric Neutral Cable: From the cable end, measure 13-3/4 inches and remove the cable jacket with a straight, smooth cut, taking care not to damage neutral wires. Bend neutral wires back and out of the way. From the cable end, measure 10-1/4 inches and remove the semi-con shield from the insulation with a straight, smooth, squared cut, avoiding nicks to the insulation. At 1 inch from the semi-con shield end, wrap two turns of tape as a marker. Bevel the insulation end at a 45-degree angle, approximately 1/4 inch back. Thoroughly clean the insulation with a rag soaked in an approved safety solvent, wiping from the cable end toward the outer jacket. Apply supplied lubricant sparingly along the cable and lubricate the inside of the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until its end is flush with the tape marker.

  4. Prepare Conductor and Install Retaining Ring

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter, ensuring not to cut or nick the cable adapter or conductor. The exposed conductor length must be 4-3/4 to 5 inches; otherwise, redo the assembly. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor measures 4-3/8 to 4-3/4 inches; otherwise, redo the assembly.

  5. Install and Crimp the Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately fully insert it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8cm), do not proceed and redo all previous work. Prior to crimping, confirm components are positioned correctly to align bolt holes in the crimp connectors with the mating part. Crimp the connectors following the instructions packaged with them, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar; if over 7 inches, redo all previous work.

  6. Assemble Washers, Bolts, and Torque

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the bolt. WARNING: The splice and cables are now in their final positions. Do not attempt to move or reposition any part of the assembly after the bolts are tightened. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs.

  7. Lubricate and Position Receptacle Housing

    Apply the supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the splice section area, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  8. Complete Housing Assembly with Tool

    Attach the appropriate assembly tool (650ATY or 600RRT) as shown in the instructions. If using the 650ATY tool, ensure the 'U' shaped yoke is over the splice section and the 'C' shaped yoke is over the receptacle housing, then slowly raise the handle to slide the receptacle housing over the splice section. If using the 600RRT tool, slide the receptacle housing over the interface by turning the hex nut on either end of the tool. WARNING: DO NOT place hand on the threaded rod or guide shaft with the assembly tool in place. Remove the venting rod.

  9. Perform Final Checks and Grounding

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. Complete the installation of the ECS grounding device according to its included instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye, and connect to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.