Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656SR-M0360 - 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.

ABB Installation Products K656SR-M0360 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining…

UPC: 783786797455


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656SR-M0360 is a 600 Amp, 15/25kV deadbreak straight receptacle designed for fully shielded, submersible cable connections on high-voltage apparatus bushings. This 600 Series component enables straight cable termination on switchgear or electrical apparatus equipped with 600 Amp bushings, supporting conductor sizes from #2 AWG to 1250 kcmil for both aluminum and copper cables. The molded rubber housing is fully shielded and submersible, constructed with 100% peroxide-cured EPDM materials for long-term reliability in demanding environments. Key specifications include a continuous current rating of 600 Amps and momentary withstand of 25kA symmetrical for 10 cycles. For the 15kV class, the receptacle meets 8.3kV phase-to-ground and 14.4kV phase-to-phase operating voltages, with a 95kV BIL impulse withstand and 34kV AC one-minute withstand. The 25kV class supports 16.2kV phase-to-ground and 28kV phase-to-phase voltages, with a 140kV BIL impulse withstand and 45kV AC one-minute withstand. Corona extinction sensitivity is 3pC at 11kV AC for 15kV class and 21.5kV AC for 25kV class. The K656SR-M0360 accommodates cable insulation diameters from 1.370 inches to 1.630 inches, with an aluminum compression lug rated for compressed stranded conductors up to 650 kcmil, compacted solid conductors up to 750 kcmil, or compacted mm² conductors up to 400 mm². The integrated cable adapter, lug, and retaining ring ensure secure assembly and reliable electrical termination. A non-corrosive capacitive test point allows for safe voltage verification without de-energizing the system. Optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, and testing, as well as adding taps for expanded functionality. This receptacle is ideal for applications requiring high-capacity power transmission in industrial, utility, and commercial switchgear environments where submersible, fully shielded connections are critical. The deadbreak design allows for safe connection and disconnection in a de-energized state, minimizing downtime during maintenance or reconfiguration.
  • 600 Amp continuous current rating with 25kA symmetrical momentary withstand
  • Fully shielded, submersible molded rubber housing with 100% peroxide-cured EPDM construction
  • Accommodates cable insulation diameters from 1.370" to 1.630" and conductor sizes up to 1250 kcmil
  • Includes aluminum compression lug, cable adapter, retaining ring, and capacitive test point
  • Aluminum compression lug compatible with 650 kcmil stranded, 750 kcmil solid, or 400 mm² compacted conductors.

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
650 kcmil , 750 to 800 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K656DLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656DLR-K0300

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655DLR-N0380

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655SR-J0330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K655DLR-H0240

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation .980-1.180 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact

K655DLR-J0330

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation .980-1.180 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact
15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter - .760-.950 inch, Aluminum Lug, Conductor Size 270 - 4/0 Stranded/Compressed or 250 Compact/Solid.

K655DLR-G0270

15/25kV, 600 Amp, Elbow with Direct Test and Sealing Kit. Cable Insulation Diameter - .760-.950 inch, Aluminum Lug, Conductor Size 270 - 4/0 Stranded/Compressed or 250 Compact/Solid.

Frequently Asked Questions

What is the K656SR product designed for?

The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings, allowing a straight cable connection on switchgear or electrical apparatus.

Does the receptacle have a test point?

Yes, the K656SR features a non-corrosive capacitive test point.

Is a ground kit recommended for metallic tape shield cables?

Yes, when used on metallic tape shield or drain wire cable, an ECS ground kit/cable seal is recommended.

What standard does the K656SR meet?

The K656SR meets ANSI/IEEE Standard 386, Latest Revision.

What is included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, a straight receptacle adapter, installation instructions, a cable adapter, an aluminum compression lug, an adapter retaining ring, a crimp chart, and a hardware prepack.

What is the maximum phase-to-ground operating voltage for 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.

What is the maximum phase-to-ground operating voltage for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.

Can the K656SR be connected or disconnected while energized?

No, the K656SR can be easily connected or disconnected only in a de-energized state.

Is the K656SR suitable for submersible applications?

Yes, the K656SR features a fully shielded, fully submersible molded rubber housing.

What cable insulation diameters does the K656SR support?

The K656SR supports cable insulation diameters ranging from .640 in to 1.935 in.

How to Install K656SR and M656SR Straight Receptacles

This guide provides detailed instructions for the safe and proper installation of K656SR and M656SR straight receptacles, enabling an in-line cable connection to a standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushing. Follow all safety warnings.

Estimated time: 2h

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench with 15/16 socket, Wire strippers, Hotstick, Suitable sensing device for capacitive test points, Crimping tool

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire or equivalent, Suitable connector for neutral and grounding wires

  1. Review Safety and Prepare

    DANGER: Ensure all apparatus is de-energized before installation or removal. Do not touch or move energized products. Read all instructions, inspect parts for damage and compatibility, and gather all required tools and supplies. Maintain cleanliness throughout the procedure.

  2. Prepare Apparatus Bushing

    If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface.

  3. Assemble Bushing Converter

    Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the bushing converter onto the apparatus bushing. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using the 5/8-inch brass bolt. Torque to 60 ft-lbs.

  4. Prepare Cable End

    Train the cable end and straighten it into its final position. Cut the cable end squarely to ensure maximum available length for crimp growth.

  5. Manage Concentric Neutral Wires

    If applicable, unwrap the concentric neutral wires a distance of 30 inches (76 cm). DO NOT CUT these wires. Bend and fold them back out of the way.

  6. Clean Outer Jacket

    Wipe the outer jacket of the cable clean for a distance of 38 inches (96.5 cm) or up to the concentric neutral wires.

  7. Slide Receptacle Housing

    Slide the receptacle housing onto the cable for a distance of 30 inches (76 cm).

  8. Prepare Cable Insulation

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4 to 11-1/4 inches). Do not cut or nick the cable insulation during this process.

  9. Bevel and Lubricate Cable Insulation

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6 mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield.

  10. Install Cable Adapter

    Install the cable adapter, small end first, onto the cable insulation until it is flush with the edge of the tape marker.

  11. Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor should be 4-3/4 to 5 inches (12.06cm-12.7cm). If the length is incorrect, redo the assembly from Step 8.

  12. Position and Secure Holding Collar

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew securely.

  13. Prepare and Insert Conductor into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor. Immediately insert the conductor fully into the crimp connector, which contains inhibitor.

  14. Verify Crimp Connector Length

    Measure the distance from the end of the crimp connector to the holding collar. If this distance is over 7 inches (17.8 cm), do not proceed. Redo all previous work from Step 13.

  15. Confirm Component Orientation

    Confirm that the receptacle housing, cable adapter, crimp connector, and contact adapter are oriented in the correct order. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  16. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees to ensure a secure connection.

  17. Verify Crimped Connector Length

    After crimping, measure the distance from the end of the connector to the holding collar. If the distance is over 7 inches (17.8 cm), do not proceed. Redo all previous work from Step 13.

  18. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten the bolt.

  19. Torque Bolt

    Using a torque wrench with a 15/16 socket, tighten the bolt to 50-60 ft-lbs. IMPORTANT: Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  20. Lubricate Adapters

    Generously apply the supplied lubricant or an ELASTIMOLD approved lubricant to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product.

  21. Seat Receptacle Housing

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied). Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod.

  22. Connect Grounding and Neutral Wires

    Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing. Make a small loop and twist tightly, taking care not to damage the eye. Gather together the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  23. Install Hose Clamp (35kV Only)

    FOR 35kV ONLY: Position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

  24. Perform Voltage Test (Capacitance Test Point)

    If the connector has an integral capacitance test point, remove the test point cap with a hotstick, peeling off at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Use a suitable sensing device made for capacitive test points. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. Clean and lubricate the inside surface of the cap with silicone lubricant and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.