Overview
- Fully rated 15/25kV, 600 Amp Deadbreak Receptacle
- Fully shielded, fully submersible molded rubber housing
- 100% peroxide-cured construction with insulation and conductive EPDM
- Accommodates cable insulation diameters from 1.180" to 1.465"
- Includes aluminum compression lug for 300 kcmil stranded or 350 kcmil solid conductors
Specifications
Amperage Rating | 600 A |
Application | 15/25kV, 600 Amps |
Color | Black |
Conductor Range | 300 kcmil , 350 kcmil |
Connection | Compression |
Environmental Conditions | All Weather Conditions, Fully Submersible |
Insulation | True |
Length | 16.98 in |
Length | 431.292 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle with Test Point |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K656LRG0290-S
15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 300 or Solid 350 or mm2 150. With Cold-Shrinkable Jacket Seal.
K656SR-J2270
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.
K656SR-J0270
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.
K656SR-L0320
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.
K656SR-M0360
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.
K656DLR-L0330
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
K656DLR-K0300
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
K655DLR-N0380
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.Frequently Asked Questions
What is the cable insulation diameter range?
The receptacle accommodates cable insulation diameters from 1.180 inch to 1.465 inch.
What is the voltage rating of this receptacle?
The K656SR-L0290 is rated for 15/25 kV, suitable for medium-voltage applications.
Is this receptacle part of a specific series?
Yes, it is part of ABB’s 600 Series, designed for medium-voltage power distribution.
What conductor sizes are compatible with this receptacle?
The K656SR-L0290 supports 300 kcmil compressed stranded, 350 kcmil compacted solid, or 150 mm² compact conductors.
What material is the lug made of?
The compression lug is constructed from aluminum for lightweight durability and corrosion resistance.
How to Install K656SR and M656SR Straight Receptacles
This guide provides step-by-step instructions for the safe and proper installation of K656SR and M656SR straight receptacles, ensuring an in-line cable connection to standard ANSI-386 600 amp 15kV, 25kV, or 35kV bushings. Always de-energize all apparatus before beginning installation.
Estimated time: 2h
Tools needed:
5/8-11 tap, Hex wrench, Wire strippers, Torque wrench, 15/16 socket, Hotstick, Suitable voltage sensing device
Supplies needed:
Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Loctite, No. 14 AWG copper wire (or equivalent), Suitable connector for neutral wires, Tape marker, Silicone lubricant (for test point cap)
- Prepare Apparatus Bushing
DANGER: All apparatus must be de-energized during installation or removal of parts. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the bushing converter onto the apparatus bushing, then attach the contact adapter with the bolt hole facing out, using the 5/8 inch brass bolt. Torque the brass bolt to 60 ft-lbs.
- Prepare Cable End
Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.
- Manage Concentric Neutral Wires
If applicable, unwrap the concentric neutral wires a distance of 30 inches (76cm). DO NOT CUT these wires. Bend and fold them back out of the way.
- Clean Cable Jacket and Position Receptacle Housing
Wipe the outer jacket of the cable clean for a distance of 38 inches (96.5cm) or up to the concentric neutral wires. Slide the receptacle housing onto the cable a distance of 30 inches (76cm).
- Prepare Cable Insulation and Semi-con Shield
Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4 inches or 26.04cm from the end, and 11-1/4 inches or 28.58cm from the end). Be careful not to cut or nick the cable insulation.
- Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Expose Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4 inches to 5 inches (12.06cm-12.7cm). If not, redo the assembly.
- Install Holding Collar
Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew. The exposed conductor length from the holding collar should be 4 3/8 inches to 4 3/4 inches (11.11cm-12.06cm).
- Prepare and Insert Crimp Connector
Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If this distance is over 7 inches (17.8cm), do not proceed; redo all previous work. The expected distance is 6 3/4 inches to 7 inches (17.14cm-17.8cm).
- Confirm Component Orientation
Confirm that all components (Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter) are oriented in the correct order. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.
- Crimp Connectors
Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If the distance is over 7 inches (17.8cm), do not proceed; redo all previous work. The expected distance is 6 3/4 inches to 7 inches (17.14cm-17.8cm).
- Assemble Washers and Bolt
Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate Cable and Bushing Adapters
Apply the supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the diagrams. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product or its mating product.
- Seat Receptacle Housing and Ground
Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod. Connect a short piece of No. 14 AWG copper wire (or equivalent) to the grounding eye of the receptacle housing, forming a small loop and twisting tightly without damaging the eye. Gather the concentric neutral wires and, using a suitable connector, connect them to the grounding wire.
- Install Hose Clamp (35kV Only)
FOR 35kV ONLY: Position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.
- Perform Voltage Test (Post-Installation)
WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Remove the test point cap with a hotstick, peeling it off at an angle. Test with a suitable sensing device, made for use with separable connectors with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.