Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655LRM16-J0290 - 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

ABB Installation Products K655LRM16-J0290 600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable…

UPC: 783786393527


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655LRM16-J0290 is a 600 Series Elbow termination kit designed for medium-voltage cable systems rated at 15/25KV. This kit includes an insulated plug, cap, stud, lug, and cable adapter, ensuring secure and reliable connections for cables with insulation diameters between 0.980 inch and 1.180 inch. The aluminum compression lug is compatible with conductor sizes of 300 kcmil compressed/stranded or 350 kcmil compact/solid, as well as 150 mm² compact conductors. Engineered for durability and performance, this termination kit is ideal for industrial power distribution, substations, and renewable energy applications where medium-voltage cable management is critical. The compression lug design ensures low-resistance connections, reducing heat buildup and improving system efficiency. Compliance with industry standards for medium-voltage terminations ensures reliability in harsh environments. This product is part of ABB’s Installation Products line, known for precision-engineered solutions in electrical infrastructure.
  • Rated for 15/25KV medium-voltage applications
  • Compatible with cable insulation diameters from 0.980 to 1.180 inch
  • Aluminum compression lug supports 300/350 kcmil or 150 mm² compact conductors
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Designed for reliable terminations in industrial and utility power systems

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
300 kcmil , 350 kcmil
Connection Type
Compression Lug
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
0.980 inch to 1.180 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4000 L
Package Weight (Metric)
2.9030 kg
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K656LR-J0290

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-J0240

15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. C Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold-Shrinkable Jacket Seal Included.

K655LR-J-0300-S

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. C Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 250 or Compact/Solid 300.

K655LR-H2280

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 250 or Compact/Solid 300.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 600 or Compact/Solid 700.

K655LR-J0350

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 600 or Compact/Solid 700.
15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LR-P0380

15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.

K655LR-H0250

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed/Stranded 2/0 or Solid/Compact 3/0 or mm2 70.

Frequently Asked Questions

What voltage rating does this elbow termination support?

The K655LRM16-J0290 is rated for 15/25KV medium-voltage applications.

What cable insulation diameter range is compatible?

This termination kit supports cable insulation diameters from 0.980 inch to 1.180 inch.

What conductor sizes does the aluminum lug accommodate?

The aluminum compression lug supports 300 kcmil compressed/stranded or 350 kcmil compact/solid conductors, as well as 150 mm² compact conductors.

What materials are used in the construction of this kit?

The kit features an aluminum compression lug and insulated components for durability and electrical safety.

Is this termination kit suitable for outdoor installations?

The kit includes an insulated plug and cap, making it suitable for outdoor and industrial environments.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and setup of 655/675LR and K655/K675LR deadbreak elbow connectors, including cable preparation, lug crimping, and connection to high voltage apparatus. Ensure all apparatus are de-energized before starting.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Wire brush, Hotstick, Voltage sensing device, Torque wrench

Supplies needed:

K655LRM16-J0290 Deadbreak Elbow Connector Kit, Cable, Tape marker, Grounding wire (No. 14 AWG Copper or equivalent), Grounding connector, Silicone lubricant, HV insulated cap(s) or connector(s)

  1. De-energize All Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Failure to follow this instruction will result in serious or fatal injury.

  2. Inspect Components

    Check the contents of the package to ensure all parts are complete and undamaged. Inspect all components for proper rating, damage, and compatibility with the cable and/or mating products.

  3. Prepare Cable Position

    Assemble the cable in its final assembled position, ensuring enough slack for adequate clearance to remove the elbows. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  4. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires.

  5. Prepare Cable End

    Remove the outer jacket (where applicable) and prepare the cable according to the specific type (e.g., non-jacketed, jacketed, unishield, lead sheath, flat metallic tape shield, fabric tape shield, longitudinally corrugated shield) as shown in the provided diagrams. Ensure proper dimensions for cable insulation, semi-con shield, and tape marker.

  6. Bevel and Lubricate Cable Insulation

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean the cable insulation, then lubricate it, always working toward the semi-con shield.

  7. Install Cable Adapter

    Install the cable adapter, small end first, onto the cable insulation until it is flush with the edge of the tape marker.

  8. Trim Cable Insulation and Verify Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution not to cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4” and 4-9/16” (108mm-116mm). If the length is incorrect, redo the assembly.

  9. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping (it should be less than 6-3/8”). Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm); otherwise, redo the assembly.

  10. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  11. Prepare Mating Products for Connection

    Remove any protective caps from the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.

  12. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  13. Connect Opposite Mating Part

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the specific instructions supplied with that mating part.

  14. Install Insulating Plug (If Applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Proceed to the voltage test directions.

  15. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device, or through an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  16. Torque L-Kit Components (If Applicable)

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque per the instructions provided with the L-Kit.

  17. Perform Voltage Test

    To establish whether the circuit is energized, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury.

  18. Replace Voltage Test Cap

    After the voltage detection has been made, clean and lubricate the inside surface of the test point cap with silicone lubricant and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.