Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656SR-J0270 - 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.

ABB Installation Products K656SR-J0270 600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining…

UPC: 783786797134


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Series Straight Receptacle, SKU K656SR-J0270, is engineered for robust performance in 15/25kV electrical systems, featuring a substantial 600 Amp rating. The comprehensive package includes a cable adapter, a lug for conductor termination, and a retaining ring to ensure a secure and reliable connection. Designed to accommodate a specific range of cable sizes, this receptacle is compatible with cable insulation diameters from 0.980 inches up to 1.180 inches. The integrated aluminum compression lug is a key component for conductor termination, offering versatility for various conductor types. It is specifically designed to accept compressed stranded conductors sized at 4/0 AWG. Alternatively, it can be used with compacted solid conductors measuring 250 kcmil. For metric conductor sizes, the lug is suitable for 125 mm² compacted conductors. This component is a part of ABB's extensive Installation Products offering, identified by the UNSPSC code 39121421. The design prioritizes reliable electrical connections within medium voltage applications, ensuring consistent performance and safety.
  • 600 Amp current rating
  • 15/25kV voltage class
  • Accommodates 0.980" - 1.180" cable insulation diameter
  • Includes cable adapter, lug, and retaining ring
  • Aluminum compression lug for 4/0 AWG, 250 kcmil, or 125 mm² conductors

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amps
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.

K655SR-J0270

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 or Compacted Solid 250 kcmil or mmSquared Compact 125.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.

K656SR-L0320

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 450 or Compacted Solid 500/550.
600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.

K656SR-M0360

600 Amp, 15/25kV, 600 Series Straight Receptacle with cable adapter, lug and retaining ring. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 650 or Compacted Solid 750 or mmSquared Compact 400.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.

K656DLR-L0330

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300.
600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656DLR-K0300

600 Amp, 15/25kV, 600 Series Deadbreak Direct Test Elbow with Test Point, (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size kcmil Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655DLR-N0380

15/25kV, Deadbreak, 600 Series Direct Test Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655SR-J0330-SG3

600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 500 or Compacted Solid 600 or mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What items are included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

What is the continuous current rating for the receptacle?

The continuous current rating for both 15kV and 28kV voltage classes is 600 Amps.

What is the maximum operating voltage for the 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.

Which industry standard does this product meet?

The K656SR meets ANSI/IEEE Standard 386, Latest Revision.

What is the acceptable cable insulation diameter range?

The K656SR is compatible with cable insulation diameters ranging from 0.640 inches to 1.935 inches.

What conductor sizes and types are compatible?

The K656SR product range supports #2 AWG to 1250 kcmil for aluminum and copper conductors.

What is the K656SR designed for?

The K656SR provides a fully shielded, submersible cable connection on 15/25kV high-voltage apparatus bushings, allowing straight cable connections on switchgear or electrical apparatus.

What conductor sizes and types are compatible?

The K656SR product range supports #2 AWG to 1250 kcmil for aluminum and copper conductors.

What items are included in each K656SR kit?

Each kit contains a straight receptacle housing, silicon lubricant, straight receptacle adapter, installation instructions, cable adapter, aluminum compression lug, adapter retaining ring, crimp chart, and hardware prepack.

How to Install K656SR and M656SR Straight Receptacles

This guide provides step-by-step instructions for the safe installation of K656SR and M656SR straight receptacles, ensuring proper cable connection to ANSI-386 600 amp bushings. Always ensure all apparatus are de-energized before beginning installation to prevent serious injury.

Estimated time: 2h 30m

Tools needed:

5/8-11 tap, Hex wrench, Torque wrench with 15/16 socket, Wire strippers, Hotstick (for voltage test)

Supplies needed:

Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Hose clamp (35kV only), Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricant (supplied), Brass bolt, Bushing converter contact, Loctite, Tape marker, No. 14 AWG copper wire or equivalent, Suitable connector for neutral and grounding wires, Silicone lubricant (for test point cap)

  1. Prepare Apparatus Bushing

    DANGER: Ensure all apparatus are de-energized. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the threads of the brass bolt. Assemble the contact adapter to the apparatus bushing, with the bolt hole facing out, using a 5/8” brass bolt. Torque to 60 ft-lbs.

  2. Prepare Cable End

    Train the cable end and straighten it into its final position. Cut the cable squarely to ensure maximum available length for crimp growth.

  3. Manage Concentric Neutral Wires

    If applicable, unwrap the concentric neutral wires a distance of 30” (76cm). DO NOT CUT these wires. Bend and fold them back out of the way.

  4. Clean Outer Jacket

    Wipe the outer jacket clean for a distance of 38” (96.5cm) or up to the concentric neutral wires.

  5. Position Receptacle Housing

    Slide the receptacle housing onto the cable a distance of 30” (76cm).

  6. Prepare Cable Insulation

    Remove the semi-con shield and install a tape marker to the dimensions shown in the documentation (10-1/4” (26.04cm) from the end, and 11-1/4” (28.58cm) from the end of the semi-con shield). Be careful not to cut or nick the cable insulation.

  7. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  8. Expose Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should be 4 3/4” – 5” (12.06cm-12.7cm). If not, redo the assembly.

  9. Secure Holding Collar

    Position the holding collar over the conductor and flush against the cable adapter. Using the supplied hex wrench, tighten the setscrew.

  10. Prepare Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable wire, brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar. If the distance is over 7” (17.8cm), do not proceed and redo all previous work.

  11. Confirm Component Alignment

    Confirm that all components (Receptacle Housing, Cable Adapter, Crimp Connector, Contact Adapter) are oriented in the correct order. Crucially, confirm that the bolt hole in the crimp connector is aligned with the bolt hole in the contact adapter.

  12. Crimp Connector

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If the distance is over 7” (17.8cm), do not proceed and redo all previous work.

  13. Secure Connection Bolt

    Assemble the washers and bolt in the following order: Flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. Using a torque wrench with a 15/16 socket, tighten to 50-60 ft-lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  14. Lubricate Interface and Seat Housing

    Apply the supplied lubricant or ELASTIMOLD approved lubricant generously to the outside of the cable adapter and the area of the bushing adapter as shown in the documentation. DO NOT SUBSTITUTE other lubricants. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the supplied nylon venting rod. Slide the receptacle housing onto the bushing converter until it is fully seated. Remove the venting rod.

  15. Connect Grounding and Neutral Wires

    Connect a short piece of No. 14 AWG copper wire or equivalent to the grounding eye of the receptacle housing. Make a small loop and twist tightly, taking care not to damage the eye. Gather together the concentric neutral wires. Using a suitable connector, connect the neutral wires and the grounding wire.

  16. Install Hose Clamp (35kV Only)

    FOR 35kV ONLY: Position the hose clamp between the locator bumps on the receptacle housing. Tighten the clamp until an audible click is heard.

  17. Perform Voltage Test (Safety Verification)

    WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Remove the test point cap with a hotstick, peeling it off at an angle. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.