ABB - Installation Products K656LRTP-M0410-DRG - 600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000.

ABB Installation Products K656LRTP-M0410-DRG 600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap.…

UPC: 075114309189


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LRTP-M0410-DRG is a 600 Amp, 25kV deadbreak connector kit designed for reliable power distribution in utility and industrial applications. This Stick-Op connector kit features a test point for diagnostic capabilities and an insulated cap for enhanced safety during handling and maintenance. Engineered for conductors with a cable insulation diameter ranging from 1.370 inches to 1.630 inches, this kit is suitable for 1000 AWG compressed stranded aluminum conductors. The deadbreak connection type ensures a secure and fault-tolerant termination, critical for underground and overhead power systems. The aluminum compression lug provides a robust and conductive connection, minimizing resistance and heat buildup. The integrated test point allows for voltage verification and troubleshooting without de-energizing the system, improving operational efficiency and safety. This connector kit meets ANSI/IEEE Standard 386 (Latest Revision) with the following ratings for 25kV voltage class: 15.2kV max phase-to-ground operating voltage, 26.3kV max phase-to-phase, 125kV BIL impulse withstand, 40kV AC one-minute withstand, 78kV DC 15-minute withstand, and 19kV AC corona extinction at 3pC sensitivity. It supports a continuous current rating of 600 Amps and a momentary rating of 25kA symmetrical for 10 cycles. The Stick-Op design allows direct testing and grounding with no required cable movement, providing an external visible break via hotstick removal of the elbow. This design is ideal for deadfront construction, reducing space requirements—particularly significant at higher voltage levels. The kit includes a hex-broach for torque installation and is constructed of peroxide-cured EPDM molded rubber with an all-copper current path.
  • 600 Amp continuous current rating with 25kA momentary rating
  • Deadbreak connection type for secure, fault-tolerant termination
  • Stick-Op design enables direct testing and grounding without cable movement
  • Test point for voltage verification and troubleshooting without system de-energization
  • Accommodates cable insulation diameter from 1.370" to 1.630"

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
1000 kcmil
Connection Type
Deadbreak
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Mounting Type
Stick-Op
Series
K656LRTP
Size
1.370" - 1.630"
Special Features
Reducing Tap Plug 600 to 200 Amps. Test Point. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector with Test Point
Voltage Rating
15 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656CYP0410P0410P041

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K656LRTP-H0270-DRG

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15kV, 600 Amp, DeadBreak, Stick Op Kit, Cable Insulation .640-.820 inches. Aluminum Compression Lug. Connector Size 1/0 Stranded/Compressed or 2/0 Compact/Solid.

655LRTP-F0240

15kV, 600 Amp, DeadBreak, Stick Op Kit, Cable Insulation .640-.820 inches. Aluminum Compression Lug. Connector Size 1/0 Stranded/Compressed or 2/0 Compact/Solid.
35kV, 600 Series Deadbreak Connector Combo Elbow with Integral 200 Amp Loadbreak Tap Plug, without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.

K655CETPH0270DRGSG3

35kV, 600 Series Deadbreak Connector Combo Elbow with Integral 200 Amp Loadbreak Tap Plug, without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.
900 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. Copper Conductor Only.

K676LRTP-M2400-DRG

900 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. Copper Conductor Only.
25 kV, 600 Amp, Deadbreak, Stick Op Connector Kit, with Test Point, Insulated Cap, Stick-Op Loadbreak Reducing Tap Plug, 600 Series Housing, Cable Adapter, and threaded 0360 Style Compression Lug. Cable Insulation Diameter 1.370-1.630. Conductor Size 1000 Compact/Solid, No Sealing Kit

K656LRTP-M5400-DRG

25 kV, 600 Amp, Deadbreak, Stick Op Connector Kit, with Test Point, Insulated Cap, Stick-Op Loadbreak Reducing Tap Plug, 600 Series Housing, Cable Adapter, and threaded 0360 Style Compression Lug. Cable Insulation Diameter 1.370-1.630. Conductor Size 1000 Compact/Solid, No Sealing Kit
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. FB - Fixed Bolt.

656LRTPFB-L5330

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. FB - Fixed Bolt.
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

756LRTP-N0330-DRG

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

Frequently Asked Questions

What materials are used in the connector's construction?

The connector features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

Is this connector suitable for 900 Amp applications?

No, for 900 Amp series applications, the K676LRTP product should be used instead. The K656LRTP is rated for 600 Amps.

What is the purpose of STICK-OP connectors?

STICK-OP connectors allow direct testing and grounding without cable movement and provide an external visible break by hotstick removal of the elbow.

Can surge arrestors be installed with this kit?

Yes, surge arrestors and fault current indicators can be installed with this kit, which includes a non-corrosive capacitive test point.

What safety standards does this product meet?

The product meets ANSI/IEEE Standard 386, Latest Revision.

How is the connector installed or disconnected?

The connector can be easily connected or disconnected using standard safety hand tools and equipment when the system is de-energized.

What is the impulse withstand rating?

The impulse withstand (BIL) rating is 125kV (1.2 x 50 microsecond wave).

What is the continuous current rating?

The connector kit has a continuous current rating of 600 Amps.

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase voltage is 26.3kV.

Can surge arrestors be installed with this kit?

Yes, surge arrestors and fault current indicators can be installed with this kit, which includes a non-corrosive capacitive test point.

How to Install K656/K676LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and setup of K656/K676LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus. These connectors are designed for fully shielded, submersible deadfront cable connections on 15kV and 25kV class systems.

Tools needed:

Hotstick, Suitable sensing device for capacitive test points, Wire brush, Crimping tool

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug (optional), Lubricant (silicone grease), Threaded stud (if not integrated), Vinyl plastic tape (for flat metallic shield), Tape retainer (for fabric tape shield), Tape marker (for various shields), No. 14 AWG Copper wire for grounding, Suitable grounding connector, HV insulated caps or connectors (to replace shipping covers), 10TL cable shield adapter (for UNISHIELD or LEAD SHEATH cable)

  1. Perform Initial Safety Checks and Inspection

    DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect package contents and all components to ensure they are complete, undamaged, and compatible with mating parts. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Position and Clean the Cable

    Position the cable so it is located in its final assembled position, ensuring enough slack for adequate clearance when removing elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent-back concentric neutral wires.

  3. Prepare the Cable Jacket and Shield

    Remove the outer jacket to a dimension of 12 3/4” (324mm). Based on your specific cable type (e.g., shield wires, flat metallic tape, fabric tape, longitudinally corrugated, semi-con), follow the corresponding instructions to remove or fold back the shield and install any necessary tape markers or retainers. If using UNISHIELD* CABLE or LEAD SHEATH CABLE, refer to the Installation Instructions supplied with the 10TL cable shield adapter for cable preparation and grounding. Do not cut or nick the cable insulation during this process.

  4. Install Cable Adapter and Prepare Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean, then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor should be 4 3/8”–4 11/16” (111mm–119mm); otherwise, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 6 1/2” (165mm), otherwise redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6 1/2”–7 1/4” (165mm–184mm); otherwise, redo the assembly.

  6. Install the Elbow and Prepare Mating Products

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker. DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. Remove protective caps from both the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the lubricant supplied.

  7. Connect the Elbow to the Mating Apparatus

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part. If connecting a mating part for the opposite end of the elbow, clean and lubricate it, then insert it into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per instructions provided.

  8. Install Insulating Plug (Optional) and Ground the Cable Shield

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage. Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, without damaging the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with any grounding device, or through an alternate method if no device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  9. Perform Voltage Test (Post-Installation)

    To perform a voltage test, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Treat the elbow as energized until a “no voltage” test point indication is confirmed by other means to prevent serious or fatal injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.