ABB Installation Products K656LRTP-H0270-DRG 600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap.…
UPC: 075114311816
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp continuous current rating with 25kA symmetrical momentary rating
- Stick-Op design enables safe hotstick operation and visible break without cable movement
- Integrated test point allows voltage verification without de-energizing circuits
- Accommodates 4/0 AWG to 250 kcmil conductors with 0.850-1.050in cable insulation diameter
- Accommodates 0.850" to 1.050" cable insulation diameter
Specifications
Amperage Rating | 600 to 200 A |
Application | Connect 600 Amp interface to 200 Amp Loadbreak Tap |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection Type | Deadbreak, Stick-Op |
Connection Type | Compression Lug |
Current Rating | 600 A |
Enclosure | Yes, EPDM Rubber |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Aluminum |
Series | 600 Series |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Size | 0.850 inch to 1.050 inch |
Special Features | Reducing Tap Plug 600 to 200 Amps. Test Point. Provides an External Visible Break by Hotstick Removal of the Elbow |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Stick Op Reducing Tap Plug Connector with Test Point |
Voltage Rating | 15 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

656ETP-H0270-DRG-S
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
655LRTP-F0240
15kV, 600 Amp, DeadBreak, Stick Op Kit, Cable Insulation .640-.820 inches. Aluminum Compression Lug. Connector Size 1/0 Stranded/Compressed or 2/0 Compact/Solid.
K655CETPH0270DRGSG3
35kV, 600 Series Deadbreak Connector Combo Elbow with Integral 200 Amp Loadbreak Tap Plug, without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Aluminum Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.
K676LRTP-M2400-DRG
900 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, With Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. Copper Conductor Only.
K656LRTP-M5400-DRG
25 kV, 600 Amp, Deadbreak, Stick Op Connector Kit, with Test Point, Insulated Cap, Stick-Op Loadbreak Reducing Tap Plug, 600 Series Housing, Cable Adapter, and threaded 0360 Style Compression Lug. Cable Insulation Diameter 1.370-1.630. Conductor Size 1000 Compact/Solid, No Sealing Kit
656LRTPFB-L5330
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. FB - Fixed Bolt.
756LRTP-N0330-DRG
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.Frequently Asked Questions
What is the 15-minute DC withstand voltage?
The 15-minute DC withstand voltage rating is 78kV DC.
What is the one-minute AC withstand voltage?
The one-minute AC withstand voltage rating is 40kV AC.
What is the maximum phase-to-phase voltage rating?
The maximum phase-to-phase voltage rating for this connector is 26.3kV.
Can surge arrestors be installed with this connector?
Yes, surge arrestors and fault current indicators can be installed with this connector.
How do I select the correct catalog number for my cable?
You need to determine the cable insulation diameter for the W code, choose the connector material type, and select the proper compression lug code based on conductor size for the X code.
What is included in each K656LRTP-W0X-DRG kit?
Each kit contains a 600 Series Elbow Housing, STICK-OP LB Reducing Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Silicone Lubricant, and various instruction sheets.
What is the impulse withstand rating (BIL)?
The impulse withstand (BIL) rating is 125kV (1.2 x 50 microsecond wave).
What is the continuous current rating of the connector?
The connector has a continuous current rating of 600 Amps.
How is the connector connected or disconnected?
It can be easily connected or disconnected using standard safety hand tools and equipment, but only in de-energized conditions.
What type of housing does the connector feature?
It features a fully shielded, fully submersible molded rubber housing made of 100% peroxide-cured EPDM materials.
How to Install K656/K676LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and preparation of 600-ampere or 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems, including cable preparation, lug crimping, and connection to mating products.
Estimated time: 1h 30m
Tools needed:
Hotstick, Wire brush, Crimping tool, Suitable sensing device for capacitive test points, Suitable connector for grounding wire
Supplies needed:
Elbow connector, Cable adapter, Compression lug, Insulating plug, Lubricant, Stud prepack, Tape marker, Vinyl plastic tape, Tape retainer, Ground wire (min. No. 14 AWG Copper), Protective caps, Threaded stud, Silicone grease
- De-energize Apparatus and Inspect Components
DANGER: Ensure all apparatus is de-energized during installation or removal. Inspect all parts for damage, correct rating, and compatibility with mating products. Read all installation instructions completely before starting the procedure.
- Position and Prepare Cable
Position the cable in its final assembled location with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires.
- Prepare Cable Jacket and Shield
Remove the outer jacket to 12 3/4” (324mm). Fold back shield wires. For flat metallic tape, remove and secure with vinyl tape to 10 3/4” (273mm). For fabric tape, remove and install retainer/marker to 9 3/4” (248mm) and 10 3/4” (273mm). For corrugated shield, remove and install marker flush to 10 3/4” (273mm). For semi-con shield, remove and install marker to 9 3/4” (248mm) and 10 3/4” (273mm). Do not cut or nick the cable insulation.
- Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare Conductor and Crimp Lug
Remove protruding cable insulation even with adapter. Exposed conductor length must be 4 3/8” to 4 11/16” (111mm to 119mm). For aluminum, wire brush conductor immediately. Fully insert conductor into compression lug. Measure “Check Dimension” (< 6 1/2” (165mm)). Crimp lug per instructions. Wipe excess inhibitor. Verify lug to adapter distance is 6 1/2” to 7 1/4” (165mm to 184mm) after crimping.
- Install Elbow
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Confirm the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect to Mating Product
DANGER: Do not connect or disconnect mating products while energized. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if it doesn't have one. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud.
- Connect Opposite Mating Part (if applicable)
Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage threads, and hand tighten. Torque the mating part according to its specific instructions. If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap and push it onto the elbow until it snaps into place.
- Ground the Cable Shield
Insert one end of a wire (at least No. 14 AWG Copper) through the grounding eye and twist to form a small loop. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded according to instructions for any grounding device used, or via an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (Optional but Recommended)
Remove the test point cap using a hotstick, peeling it off at an angle. WARNING: Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until “no voltage” is confirmed by other means. After testing, clean, lubricate cap with silicone grease, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.