ABB - Installation Products K656LRTP-M5400-DRG - 25 kV, 600 Amp, Deadbreak, Stick Op Connector Kit, with Test Point, Insulated Cap, Stick-Op Loadbreak Reducing Tap Plug, 600 Series Housing, Cable Adapter, and threaded 0360 Style Compression Lug. Cable Insulation Diameter 1.370-1.630. Conductor Size 1000 Compact/Solid, No Sealing Kit

ABB Installation Products K656LRTP-M5400-DRG 25 kV, 600 Amp, Deadbreak, Stick Op Connector Kit, with Test Point, Insulated Cap…

UPC: 075114311823


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LRTP-M5400-DRG is a 25 kV, 600 Amp deadbreak stick-operated connector kit designed for reliable power distribution connections. This kit includes a stick-op loadbreak reducing tap plug, a test point for diagnostic capabilities, and an insulated cap for enhanced safety. It is engineered to fit the 600 Series housing and comes with a cable adapter. The included threaded 0360 style compression lug ensures a secure conductor connection. This connector kit is suitable for cable insulation diameters ranging from 1.370 to 1.630 inches and accommodates conductor sizes of 1000 Compact/Solid. It does not include a sealing kit. The UNSPSC code for this product is 39121421. Manufacturer: ABB - Installation Products. SKU: K656LRTP-M5400-DRG. This component facilitates safe and efficient loadbreak operations in medium-voltage applications.
  • 25 kV voltage rating
  • 600 Amp current rating
  • Deadbreak stick-operated design
  • Includes test point and insulated cap
  • Accommodates 1.370-1.630" cable insulation diameter

Specifications

Amperage Rating
600 to 200 A
Application
Connect 600 Amp interface to 200 Amp Loadbreak Tap
Color
Black
Conductor Range
900 kcmil , 1000 kcmil
Connection Type
Deadbreak, Stick-Op
Current Rating
600 A
Enclosure
Yes, EPDM Rubber
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
600 Series
Size
Cable Insulation Diameter 1.370-1.630 inch
Special Features
Reducing Tap Plug 600 to 200 Amps. Test Point. Provides an External Visible Break by Hotstick Removal of the Elbow
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Stick Op Reducing Tap Plug Connector with Test Point
Voltage Rating
15 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

755LR-Q0400

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. FB - Fixed Bolt.

656LRTPFB-L5330

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. FB - Fixed Bolt.
600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

756LRTP-N0330-DRG

600 Amp, 35kV, Deadbreak, Stick-Op Connector Kit, with Capacitive test point, Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.
600 Amp, 15kV, Deadbreak, Stick-Op Replacement Connector Kit. Fixed Bolt. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.

655RLRTP-FB-M0380

600 Amp, 15kV, Deadbreak, Stick-Op Replacement Connector Kit. Fixed Bolt. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

656LRTP-L-0330-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Stick-OP Elbow Connector Kit, Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Fixed Bolt, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

K656LRTPFB-N0410

600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Fixed Bolt, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, with Fixed Bolt. Cable Insulation Diameter 0.675 inch to 0.785 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

655LRTP-FB-M0380

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, with Fixed Bolt. Cable Insulation Diameter 0.675 inch to 0.785 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage for the 25kV voltage class is 15.2kV.

What is the continuous current rating?

The connector kit has a continuous current rating of 600 Amps.

What is the corona extinction voltage?

The corona extinction voltage is 19kV AC at 3pC sensitivity.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 cycles.

What is the maximum phase-to-phase voltage?

The maximum phase-to-phase voltage for the 25kV voltage class is 26.3kV.

What standards does this product meet?

The product meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand voltage?

The impulse withstand (BIL) is 125kV (1.2 x 50 microsecond wave).

What is the corona extinction voltage?

The corona extinction voltage is 19kV AC at 3pC sensitivity.

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage for the 25kV voltage class is 15.2kV.

What is the continuous current rating?

The connector kit has a continuous current rating of 600 Amps.

How to Install 656/676LR and K656/K676LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation of 656/676LR and K656/K676LR Deadbreak Elbow Connectors, covering cable preparation, lug crimping, and connection to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Utility knife or cable preparation tool, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

656/676LR or K656/K676LR Deadbreak Elbow Connector Kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), Vinyl plastic tape, Tape retainer, Tape marker, Grounding wire (minimum No. 14 AWG Copper equivalent), Suitable grounding connector, Silicone grease, Waterproofing material (for cable jacket, recommended), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Ensure Safety and Inspect Components

    DANGER: De-energize all apparatus before installation or removal of parts. Ensure all deadbreak connectors are de-energized before operation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow these instructions will result in serious injury or death. Inspect all package contents to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Have all required tools readily available and maintain cleanliness throughout the procedure.

  2. Position Cable and Prepare for Cutting

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  4. Prepare Cable Outer Jacket and Shield

    Remove the cable's outer jacket to the specified dimension (12 3/4 inches or 324mm). Prepare the cable shield according to its type: fold back shield wires, remove flat metallic tape shield and secure with vinyl tape (10 3/4 inches or 273mm), remove fabric tape shield and install tape retainer/marker (9 3/4 inches or 248mm for retainer, 10 3/4 inches or 273mm for marker), remove longitudinally corrugated shield and install tape marker (10 3/4 inches or 273mm), or remove semi-con shield and install tape marker (9 3/4 inches or 248mm for shield, 10 3/4 inches or 273mm for marker). For UNISHIELD* or lead sheath cables, refer to 10TL cable shield adapter instructions.

  5. Bevel and Clean Cable Insulation, Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Prepare Conductor Length

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Ensure the exposed conductor length is 4 3/8 inches to 4 11/16 inches (111mm to 119mm). Do not cut or nick the cable adapter or the conductor.

  7. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the 'Check Dimension' (must be less than 6 1/2 inches or 165mm) before crimping. Crimp the compression lug following the supplied instructions. Wipe off any excess inhibitor. Verify the distance from the end of the lug to the cable adapter is 6 1/2 inches to 7 1/4 inches (165mm to 184mm) after crimping.

  8. Install Elbow onto Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Confirm the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  9. Prepare Mating Products

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect Elbow to Mating Part

    Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part. Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its supplied instructions.

  11. Install Insulating Plug (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down firmly until the cap snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage. Follow VOLTAGE TEST directions below.

  12. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper equivalent) through the grounding eye and twist to form a small loop. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded according to the instructions supplied with the grounding device or via an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  13. Perform Voltage Test (if required)

    CAUTION: When constructing 600amp L-Kits, tighten each component to specified torque per instructions provided. To perform a voltage test, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.