ABB - Installation Products K656LR-J2270 - 25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 4/0 Stranded/Compressed or 250 kcmil Compact/Solid. No Sealing Kit.

ABB Installation Products K656LR-J2270 25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Copper…

UPC: 075114391801


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products K656LR-J2270 Deadbreak Elbow Kit is a 25 kV, 600 Amp rated accessory designed for medium-voltage cable systems. This deadbreak elbow terminates 4/0 stranded/compressed or 250 kcmil compact/solid copper conductors with cable insulation diameters between 0.980" and 1.180". The kit includes a test point for safe voltage verification, an insulated plug for system isolation, a protective cap, a threaded stud for mechanical attachment, a copper lug for conductor termination, and a cable adapter to ensure proper fit. This elbow is part of ABB’s medium-voltage accessory line, optimized for use in pad-mounted transformers, switchgear, and underground distribution systems. The deadbreak design allows for hot-stick operation, enabling safe connection and disconnection under load without de-energizing the system. The 600 Amp rating supports high-current applications, while the 25 kV insulation rating ensures compatibility with standard medium-voltage networks.
  • 25 kV, 600 Amp deadbreak elbow for medium-voltage cable systems
  • Supports 4/0 stranded/compressed or 250 kcmil compact/solid copper conductors
  • Cable insulation diameter range: 0.980"–1.180"
  • Includes test point, insulated plug, cap, stud, copper lug, and cable adapter
  • Hot-stick operable for safe connection/disconnection under load

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.

K656CETP-J0270

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 450 kcmil or Compact/Solid 500/550 kcmil. No Sealing Kit.

K656LR-LM0320

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 450 kcmil or Compact/Solid 500/550 kcmil. No Sealing Kit.
15/25kV, 600 Amp, Deadbreak Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. No test point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size #1 Compressed/Stranded or 1/0 Solid/Compact or 50 mm2 Compact Only.

K655CETP-G0230

15/25kV, 600 Amp, Deadbreak Combo T Elbow Reducing Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. No test point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size #1 Compressed/Stranded or 1/0 Solid/Compact or 50 mm2 Compact Only.
25kv, 600 Amp Series, Deadbreak Combo-T Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Shearbolt Conductor Code AC01 - #2 Stranded / Compressed / Solid / Compact to 300 kcmil Stranded / Compressed / Solid / Compact. Sealing Kit. Insulating Cap.

K656CETP-JAC01-DRG

25kv, 600 Amp Series, Deadbreak Combo-T Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Shearbolt Conductor Code AC01 - #2 Stranded / Compressed / Solid / Compact to 300 kcmil Stranded / Compressed / Solid / Compact. Sealing Kit. Insulating Cap.
12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27mm), Copper Lug, Conductor Size 120 mm2. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Standard Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Includes Bonding/Grounding Wire. IEC 60502-4, CEN 629.1 S2.

252LR-E2120-G

12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27mm), Copper Lug, Conductor Size 120 mm2. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Standard Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Includes Bonding/Grounding Wire. IEC 60502-4, CEN 629.1 S2.
12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27mm), Copper Lug, Conductor Size 95 mm2. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Standard Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Includes Bonding/Grounding Wire. IEC 60502-4, CEN 629.1 S2.

252LR-E2095-G

12/20kV (24 kV), IEC 250 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.09-1.31 inches (27.48-33.27mm), Copper Lug, Conductor Size 95 mm2. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Standard Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Includes Bonding/Grounding Wire. IEC 60502-4, CEN 629.1 S2.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.

262LR-B2230

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.
25/28kV, Load Break,200 Amp Elbow without Test Point, No Sealing Kit. .890 inch - 1.220 inch Cable Insulation Diameter. Wire Size 2/0 Stranded/Compressed, 3/0 Solid/Compact, 67.43 mm2. Copper Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart, Installation Instructions.

261LR-D2250

25/28kV, Load Break,200 Amp Elbow without Test Point, No Sealing Kit. .890 inch - 1.220 inch Cable Insulation Diameter. Wire Size 2/0 Stranded/Compressed, 3/0 Solid/Compact, 67.43 mm2. Copper Compression Lug. ANSI/IEEE Standard 386. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart, Installation Instructions.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR connector accommodate?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this deadbreak elbow?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating (1.2 x 50 microsecond wave) for the 28kV voltage class is 140kV BIL.

What is the corona extinction rating for the 15kV voltage class?

The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.

What cable insulation diameters are supported by the K656LR connector?

The K656LR supports cable insulation diameters ranging from 0.640 inches to 1.935 inches.

Is a grounding device recommended for this product?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device for safety is highly recommended.

What is the momentary current rating for the K656LR connector?

The momentary current rating is 25kA Sym for 10 Cycles.

What materials are used in the construction of the K656LR housing?

The housing is made of 100% peroxide-cured molded rubber, including insulation and conductive EPDM materials.

Can the K656LR be connected or disconnected in the field?

Yes, it can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

How to Install K655/K675LR and K656LR-J2270 Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 600-ampere and 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems. Ensure all safety precautions are followed.

Estimated time: 1h

Tools needed:

Wire brush, Crimping tool, Hotstick, Suitable sensing device for capacitive test points, Torque wrench, Wire strippers, Utility knife

Supplies needed:

Elbow connector (655/675LR or K655/K675LR), Cable adapter, Compression lug, Insulating plug (if applicable), Lubricant (silicone), Threaded stud, Grounding device (e.g., 20MA, 21MA, 600ECS, or alternate), 10TL cable shield adapter (if using UNISHIELD or LEAD SHEATH cable), HV insulated cap(s) or connector(s), Wire (at least No. 14 AWG Copper equivalent), Suitable connector for grounding wire, Waterproofing material for cable jacket

  1. Perform Pre-Installation Checks and Safety Measures

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product should be installed only by competent personnel trained in high voltage electrical equipment safety. Inspect all parts for damage, proper rating, and compatibility with mating parts. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Check package contents for completeness and ensure all components fit properly with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Assemble Cable and Cut to Length

    Assemble the cable in its final position, ensuring enough slack to allow for elbow removal. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean and Prepare the Cable

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires. Follow the specific cable preparation steps for your cable type (e.g., 20MA/21MA grounding device, UNISHIELD/LEAD SHEATH with 10TL adapter, or JACKETED/NON-JACKETED cable). Remove the outer jacket where applicable and prepare the cable according to the provided diagrams, ensuring correct dimensions for insulation, semi-con shield, and tape markers.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare the Conductor

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. CAUTION: Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; this dimension should be less than 6-3/8 inches. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If not, redo the assembly.

  7. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition the cable adapter if necessary. Remove the tape marker.

  8. Prepare Mating Products for Connection

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect the Elbow to the Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect the Opposite Mating Part (if applicable)

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per instructions.

  11. Install Insulating Plug and Voltage Detection Cap (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place.

  12. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to create a small loop. CAUTION: Do not damage the grounding eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with your grounding device. If no grounding device is used, ground the shield through an alternate approved method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  13. Perform Voltage Test

    The ELASTIMOLD® deadbreak elbow connector is equipped with an integral capacitance test point. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device designed for separable connectors with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.