ABB - Installation Products K656LR-H0250-S - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656LR-H0250-S 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 075114139144


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-H0250-S is a 15/25kV, 600 Amp Series Deadbreak Elbow designed for fully shielded, dead-front submersible cable connections to high-voltage apparatus. This elbow connector is suitable for use through 28kV. It meets ANSI/IEEE Standard 386, Latest Revision. For the 15kV voltage class, it offers 8.3kV Max Phase-to-Ground operating voltage and 14.4kV Max Phase-to-Phase. For the 28kV voltage class, it offers 16.2kV Max Phase-to-Ground operating voltage and 28kV Max Phase-to-Phase. Both classes feature a 95kV BIL impulse withstand (1.2 x 50 microsecond wave) and 600 Amp continuous rating. The K656LR-H0250-S is constructed with 100% peroxide-cured EPDM materials, providing a fully molded rubber housing that is fully shielded and submersible. It can be connected or disconnected using standard hand tools in a de-energized state. The included aluminum compression lug is designed for conductor sizes of 2/0 AWG compressed/stranded or 3/0 AWG compact/solid, with a mm² compact equivalent of 70. The cable insulation diameter range is 0.850 inches to 1.050 inches. A cold-shrinkable jacket seal is included for environmental protection. The non-corrosive, capacitive test point allows for safe voltage verification without cable disconnection. Optional accessories are available for visible separation, by-pass, isolation, dead-ending, grounding, testing, and adding taps, surge arrestors, and fault current indicators. This product is ideal for utility substations, industrial power distribution, and renewable energy systems requiring reliable cable terminations.
  • Fully rated 15/25kV, 600 Amp Deadbreak Elbow with Test Point
  • Fully shielded, fully submersible molded rubber housing
  • Accommodates cable insulation diameter from 0.850" to 1.050"
  • Aluminum compression lug for 2/0 AWG compressed/stranded or 3/0 AWG compact/solid conductors (70 mm² compact)
  • Meets ANSI/IEEE Standard 386, Latest Revision

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Aluminum, Poly
Material
Housing - EPDM-Rubber
Series
K656LR
Size
0.850-1.050 inch (cable insulation diameter)
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Jacket Seal Included
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.9600 L
Package Weight (Metric)
3.1570 kg
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal

K151SR-B0250-S

15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.

K656LR-N0410-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 1000. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.

K656LR-J0230

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.

K656LR-F5250-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. Cold-Shrinkable Jacket Seal Included.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.

K655LRM2380

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 700/750 or Compact/Solid 900.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.

K655LR-N0330-S

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K656LR-G0300

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. No Sealing Kit

K656LR-F0240

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. No Sealing Kit

Frequently Asked Questions

What is the cable insulation diameter range for this elbow?

The ABB K656LR-H0250-S deadbreak elbow is designed to fit cable insulation diameters ranging from 0.850 inches to 1.050 inches.

What conductor sizes are compatible with this deadbreak elbow?

This elbow is compatible with conductor sizes of 2/0 AWG compressed/stranded, 3/0 AWG compact/solid, or 70 mm² compact. It includes an aluminum compression lug.

Does this deadbreak elbow include a test point?

Yes, the ABB K656LR-H0250-S features an integrated test point for convenient and safe testing of the connection.

What components are included with the K656LR-H0250-S deadbreak elbow?

The unit comes with an insulated plug, cap, stud, aluminum compression lug, cable adapter, and a cold-shrinkable jacket seal.

What is the voltage rating of this ABB deadbreak elbow?

The ABB K656LR-H0250-S is rated for 15/25kV applications.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 655/675LR and K655/K675LR deadbreak elbow connectors, designed for 15kV and 25kV class systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Measuring tape or ruler, Wire brush (for aluminum conductors), Crimping tool (for compression lugs), Torque wrench, Hotstick, Suitable sensing device (for capacitive voltage test)

Supplies needed:

655/675LR or K655/K675LR Deadbreak Elbow Connector kit (including Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack, Crimp chart), Cable (concentric neutral, unishield, lead sheath, jacketed, or non-jacketed), Mating product (high voltage apparatus, splice, or tap), Grounding device (e.g., 20MA, 21MA, 600ECS Jacket Cable Seal) or alternate grounding method, Wire (at least No. 14 AWG Copper for grounding), Suitable connector (for grounding wire), Silicone lubricant, Waterproofing material (for cable jacket), HV insulated cap(s) or connector(s) (to replace shipping covers), Tape marker

  1. Perform Initial Checks and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Failure to follow instructions will result in serious injury. Ensure installation is performed by competent personnel trained in high voltage safety practices. Check package contents for completeness and damage. Verify all components fit properly with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable for Assembly

    Assemble the cable in its final position, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Follow specific cable preparation steps (A, B, or C) based on cable type (e.g., remove outer jacket, prepare as shown in diagrams for specific shield types, noting dimensions like 9-3/4”, 10-3/4”, 12-3/4”).

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4” – 4-9/16” (108mm-116mm). If the length is incorrect, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension must be less than 6-3/8”. If incorrect, redo the assembly. Crimp the compression lug following the crimping instructions supplied with the lug, ensuring the first crimp is located on the end closest to the cable. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is between 6-3/8” to 7-1/8” (162mm-181mm) after crimping. If incorrect, redo the assembly.

  6. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition it if necessary. Remove the tape marker.

  7. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. Hand tighten the threaded stud (supplied with the elbow) into the mating part if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.

  8. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  9. Connect Opposite Mating Part (if applicable)

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the specific instructions supplied with that mating part.

  10. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps securely into place.

  11. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device. If no grounding device is used, ground the shield through an alternate approved method. It is also recommended to waterproof the jacket of the cable at this point to prevent moisture from entering the cable.

  12. Torque Components for 600A L-Kits

    CAUTION: When constructing 600amp L-Kits, ensure that each component is tightened to the specified torque according to the instructions provided with the L-Kit.

  13. Perform Voltage Test

    Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can provide a false “no voltage” indication. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.