Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656I-H0260-S - 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K656I-H0260-S 15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point.…

UPC: 075114420358


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656I-H0260-S is a 15-25kV 600 Series 2-way deadbreak separable straight joint package designed for reliable medium-voltage cable connections. This modular kit includes an insulated bus bar, straight receptacle housing, retaining rings, cable size adapters, aluminum compression lugs, bolts, and washers. The package features a built-in capacitive test point for simplified diagnostics and safety verification in live-line applications. Engineered for cables with insulation diameters between 0.850 inches and 1.050 inches, the K656I-H0260-S accommodates conductor sizes of 3/0 AWG compressed stranded or 4/0 AWG solid aluminum. The aluminum compression lugs provide secure termination, while the cold-shrinkable jacket seal ensures robust environmental protection against moisture and contaminants. Rated for 600A continuous current with 25kA symmetrical momentary withstand, this deadbreak joint meets ANSI/IEEE Standard 386 for 15kV and 25kV voltage classes. Key electrical specifications include: - 15kV class: 8.3kV phase-to-ground, 14.4kV phase-to-phase, 95kV BIL impulse withstand - 25kV class: 16.2kV phase-to-ground, 28kV phase-to-phase, 140kV BIL impulse withstand The fully shielded, fully submersible design uses 100% peroxide-cured EPDM molded rubber for long-term reliability in harsh environments. Its compact form factor makes it ideal for installation in small vaults and manholes, while the modular construction allows for future system expansions or reconfigurations. Unused interfaces can be temporarily capped for initial 2-way operation. Applications include direct-buried installations, utility substations, industrial power distribution, and commercial infrastructure where reliable separable cable joints are required. The reusable components reduce inventory costs and simplify maintenance operations.
  • 2-way deadbreak separable straight joint package for 15-25kV systems
  • Built-in capacitive test point for live-line diagnostics
  • Accommodates 3/0 AWG compressed stranded or 4/0 AWG solid aluminum conductors
  • Cold-shrinkable jacket seal for environmental protection
  • Compact design suitable for vaults and manholes

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
3/0 COMPR/STR AWG , 4/0 SOL AWG
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
EPDM Rubber
Length
37.27 in
Length
946.658 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, 100 percent Peroxide cured Molded EODM Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Straight Joint
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0.

K151SP-C0260

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0.
25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG, Compressed / Stranded 3/0, or Compacted / Solid 4/0. With Insulated Cap and Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

K655ETP-F0220-DRGSG3

25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG, Compressed / Stranded 3/0, or Compacted / Solid 4/0. With Insulated Cap and Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation Diameter 1.180-1.465 inches, Tin Plated Aluminum Shear Bolt Connector for Aluminum or Copper Conductor Sizes 750 to 1250 kcmil Stranded / Compressed / Compact.

K656DLR-LAC04

15/25kV, Direct Test Elbow, DeadBreak, 600 Amp, Cable Insulation Diameter 1.180-1.465 inches, Tin Plated Aluminum Shear Bolt Connector for Aluminum or Copper Conductor Sizes 750 to 1250 kcmil Stranded / Compressed / Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.

168FLR3-C5240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded/Compressed, 2/0 AWG Solid/Compact.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 650 kcmil or Compacted Solid 750 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K675LR-M2360-SG3

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 650 kcmil or Compacted Solid 750 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K675LR-F2250-SG3

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Compacted Solid 3/0. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.18-1.465 inch. Connector Sizing AC03 - 500-750 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.

K655VSL2-LAC03

15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.18-1.465 inch. Connector Sizing AC03 - 500-750 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.

Frequently Asked Questions

What is the voltage rating for this ABB straight joint package?

The ABB K656I-H0260-S 600 Series Deadbreak Separable Straight Joint Package is rated for 15-25kV.

What cable insulation diameters does this joint package support?

This package is designed to fit cables with an insulation diameter ranging from 0.850 inches to 1.050 inches.

What conductor sizes are compatible with the aluminum compression lug?

The aluminum compression lug is suitable for 3/0 AWG compressed stranded or 4/0 AWG solid aluminum conductors.

Does this package include a method for sealing the jacket?

Yes, the K656I-H0260-S includes a cold-shrinkable jacket seal for robust environmental protection.

What type of joint configuration is this ABB product?

This is a 2-way deadbreak separable straight joint package.

How to Install K656 Series Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of K656CY, K656CH, and K656I Deadbreak Receptacles, including cable preparation, crimping, and final assembly for high-voltage applications.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), 650ATY or 600RRT assembly tool, Rag, Crimp tool, Cable stripping tools

Supplies needed:

K656 Series Receptacle housing, Cable adapters, I, Wye, or H Center section, Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (if used), No. 14 AWG copper wire (or equivalent) for grounding, Tape (for markers), Conductive copper strip (for flat metallic tape shielded cable), Approved safety solvent, Solid dielectric type cables (15kV or 25kV, 600A)

  1. Ensure Safety and Inspect Components

    DANGER: De-energize all apparatus in the work area before beginning installation. Do not touch or move energized products. Inspect all K656 series components for damage, proper rating, and compatibility with mating parts and cables. Verify that all package contents are complete and undamaged.

  2. Prepare the Cable

    Wipe the outer jacket of the cable clean for a distance of 38 inches and cut the cable end squarely. Based on your cable type, follow the specific preparation instructions: For Jacketed Concentric Neutral Cable, remove the jacket 13-3/4 inches, bend neutral wires, remove semi-con 10-1/4 inches, mark with tape 1 inch from semi-con end, bevel insulation 1/4 inch at 45 degrees, and thoroughly clean the insulation. For Flat Metallic Tape Shielded Cable with Semi-con Shield, remove the outer jacket 13-3/4 inches, remove tape shield 11-1/4 inches, wrap with conductive copper strip and tape marker, remove semi-con shield 10-1/4 inches, bevel insulation 1/4 inch at 45 degrees, and thoroughly clean the insulation.

  3. Install Cable Adapter and Holding Ring

    Apply lubricant sparingly along the prepared cable and generously to the inside of the cable adapter. Slide the cable adapter, small end first, over the cable with a twisting motion until its end is flush with the tape marker. Remove any protruding cable insulation by cutting it even with the end of the cable adapter, ensuring the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor, snug it firmly against the cable adapter, and hand-tighten the socket head screw using the provided hex wrench. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.

  4. Prepare and Insert Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor immediately before fully inserting it into the crimp connector, which contains inhibitor. Measure the distance from the end of the connector to the holding collar; if it exceeds 7 inches (17.8cm), redo previous work. Confirm the bolt holes in the crimp connectors are positioned properly to align with the bolt holes of the mating part.

  5. Crimp the Connectors

    Crimp the connectors according to the instructions provided with the connectors, rotating each crimp 90 or 180 degrees. After crimping, re-measure the distance from the end of the connector to the holding collar; if it exceeds 7 inches, redo previous work. Repeat Steps 3 through 5 for all remaining cables to be joined.

  6. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten all bolts. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  7. Lubricate and Slide Receptacle Housing

    Apply the supplied or ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod.

  8. Complete Housing Assembly with Tool

    Use an assembly tool (650ATY or 600RRT) to slide the receptacle housing over the splice section. If using the 650ATY, attach it with the 'U' shaped yoke over the splice section and the 'C' shaped yoke over the receptacle housing, then slowly raise the handle. If using the 600RRT, attach it and slide the housing by turning the hex nut. WARNING: Do not place hands on the threaded rod or guide shaft with the 600RRT tool in place. Remove the venting rod once the housing is in place. Repeat Steps 7 and 8 for all remaining cables.

  9. Final Checks and Grounding

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. If an ECS grounding device is being used, complete its installation according to its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye, then connect to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.