Overview
- 600 Amp continuous current rating with 25 kA symmetrical momentary withstand (10 cycles)
- Factory-assembled stud (non-removable) for consistent installation and security
- Integrated test point for safe voltage verification during diagnostics
- Molded EPDM rubber construction with provision for hotstick operation
- Integral grounding wire for proper cable shield grounding
- Meets 95 kV BIL (15 kV) and 140 kV BIL (25 kV) impulse withstand requirements
Specifications
Application | 15/25 kV |
Connection Type | Stud (factory-assembled, non-removable) |
Current Rating | 600 A |
Poles | 1P+G |
Series | 600 Series |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Insulated Cap |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.9500 L |
Package Weight (Metric) | 0.8850 kg |

K650RTW
15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps
K650-J3-6
15/25kV 600 Series Deadbreak 3-Point Junction, Hardware package consists of brackets and straps only.
K656DRGN
600 Amp, 15/25kV, 600 Series Deadbreak Insulated Cap with Test Point (without Stud), with Ground.
K650BIP-720LOT
15/25kV 600 Series Deadbreak Insulated Plug (with Cap). Material Epoxy, Length 4.5 inch, Widest Diameter 3 inch. - Lot of 720Frequently Asked Questions
What is the K656DRG insulated cap used for?
The Elastimold® insulated cap is designed to insulate, shield, and water seal 15/25kV, 600 Amp IEEE Std. 386 bushing interfaces. It also has a capacitance test point to check if the system is energized.
Does the cap have a test point to check if energized?
Yes, the unit has a capacitance test point which can be used to check if the system is energized.
What is the impulse withstand rating for the 28kV class?
For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).
How can I order the cap with a factory-assembled stud?
To order the cap with the stud factory-assembled, add “SP” to the part number.
How can I order the cap without the stud?
To order the cap without the stud, add “N” to the part number.
What items are included in the K656DRG kit?
Each kit contains one Insulated Cap w/ TP K656DRG, one Stud 650SA, one Lubricant 82-08, and Installation Instruction IS-1325.
Does the K656DRG kit include a grounding wire?
Yes, the K656DRG insulated cap features a grounding wire attached.
Can the K656DRG cap be operated with a hotstick?
Yes, the K656DRG insulated cap includes a provision for hotstick operation.
What material is the K656DRG insulated cap made from?
The K656DRG insulated cap is molded from EPDM Rubber.
What is the continuous current rating for the 28kV class?
The continuous current rating for the 28kV voltage class is 600 Amp.
How to Install the K656DR/K676DR Deadbreak Insulated Cap
This guide provides step-by-step instructions for safely installing the K656DR/K676DR Deadbreak Insulated Cap with Test Point on 15kV or 28kV class 600 amp deadbreak bushing interfaces. All apparatus must be de-energized during installation.
Estimated time: 30m
Tools needed:
Hotstick (first), Hotstick (second), Cleaning cloths or wipes, Grounding wire connector tool (as specified by utility)
Supplies needed:
K656DR/K676DR Insulated Cap, Lubricant (supplied or Elastimold approved), Stud (if supplied and needed), No. 8 Copper Grounding Wire, Grounding wire connector (utility specified)
- De-energize Apparatus and Prepare Grounding Wire and Stud
DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all parts for damage, proper rating, and compatibility with mating parts. Connect the free end of the No. 8 copper grounding wire to the system ground using a connector as specified by the utility. Ensure the grounding wire length is sufficient to reach the grounding eye of the insulated cap when installed. If the bushing is not equipped with a stud, hand assemble the supplied stud into the insulated cap. If the bushing already has a stud, discard the supplied stud.
- Clean and Lubricate Interfaces
For new installations where the bushing is known to be de-energized, thoroughly wipe both the bushing interface and the insulated cap interface clean of all contaminants. Lubricate both surfaces with the supplied lubricant or an Elastimold approved lubricant. For circuits that were previously energized, clean and lubricate only the interface of the insulated cap.
- Install Insulated Cap with Hotsticks
Wrap the grounding wire loosely around the body of the insulated cap. Attach the first hotstick tool to the insulated cap pulling ring. Push the receptacle onto the bushing interface as far as it will go. Using a second hotstick, engage the grounding wire and establish slight tension to control its position. With the first hotstick, while pushing against the bushing interface, twist clockwise until the threads between the bushing and insulated cap engage. Continue turning without pushing until resistance is felt. DO NOT OVERTIGHTEN.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.