ABB - Installation Products K655YSR-L0340 - 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 550.

ABB Installation Products K655YSR-L0340 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter…

UPC: 783786316892


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 600 Series Deadbreak Straight Receptacle, SKU K655YSR-L0340, is engineered for reliable power distribution in medium-voltage applications. This receptacle is rated for 600 Amps and operates within a voltage range of 15-25 kV, making it suitable for robust electrical systems. It features a deadbreak design, ensuring safe and secure connections. The receptacle accommodates cable insulation diameters ranging from 1.180 inches to 1.465 inches, providing flexibility for various cable sizes. Connection is facilitated by an aluminum compression lug, designed for secure and lasting electrical contact. The lug is specified for compressed stranded conductors of 550 AWG or kcmil, ensuring a precise fit for heavy-duty conductors. This ABB product is part of the 600 Series, known for its dependable performance in demanding electrical infrastructure. Key specifications include: * **Voltage Rating:** 15-25 kV * **Current Rating:** 600 A * **Cable Insulation Diameter:** 1.180" - 1.465" * **Connection Type:** Aluminum Compression Lug * **Conductor Size:** 550 AWG or kcmil (Compressed Stranded) * **Series:** 600 Series This straight receptacle is a critical component for switchgear, transformers, and other medium-voltage equipment where secure, insulated connections are paramount. The aluminum compression lug ensures minimal resistance and optimal conductivity for the specified conductor sizes. ABB's commitment to quality in their Installation Products division is evident in the robust construction and precise engineering of this receptacle, designed for long-term operational integrity in electrical distribution networks.
  • 600 Amp, 15-25 kV voltage rating for medium-voltage applications
  • 600 Series Deadbreak Straight Receptacle design for safe connections
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Aluminum compression lug for secure electrical contact
  • Compatible with 550 AWG or kcmil compressed stranded conductors

Specifications

Amperage Rating
600 A
Application
These Connectors allow a straight cable connection on Switchgear or Electrical Apparatus equipped with 600 Amp Bushings
Color
Black
Conductor Range
550 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, Can be easily Connected or Disconnected in a De-Energized State
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.

K656I-G0240-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656I-N0400-SG3

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15-25kV 600 Series Deadbreak Direct Test Straight Receptacle Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K656YDSR-H0240

15-25kV 600 Series Deadbreak Direct Test Straight Receptacle Elbow with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

K655YSR-K2320

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.

K655YSR-G2260

600 Amp Separable Cable Joints, Straight Receptacle, 15/25KV, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.
15/25kV, 600 Amps, Deadbreak Straight Receptacle without Test Point. Contains Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter F - 0.640-0.820 inch. Copper Compression Lug. Conductor Size 220 - Stranded/Compressed #2, Solid/Compact #1.

K655YSR-F2220

15/25kV, 600 Amps, Deadbreak Straight Receptacle without Test Point. Contains Cable Adapter, Lug and Retaining Ring. Cable Insulation Diameter F - 0.640-0.820 inch. Copper Compression Lug. Conductor Size 220 - Stranded/Compressed #2, Solid/Compact #1.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K655YSR-L0330

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

How do I select the correct catalog number?

To select the catalog number, determine the cable insulation diameter for the W code and the conductor size for the XXX code using the provided tables.

What is the K655YSR designed for?

The K655YSR provides a fully shielded, submersible cable connection on 15/25kV high-voltage "I", "Y", or "H" Bus.

What conductor sizes are compatible with K655YSR?

The K655YSR is compatible with #2 AWG to 1250 kcmil aluminum and copper conductors.

What cable insulation diameters does K655YSR support?

It supports cable insulation diameters from 0.640 inches to 1.935 inches.

What are the 15kV operating voltage limits?

For 15kV, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amp.

What is the momentary current rating?

The momentary current rating for both 15kV and 25kV voltage classes is 25kA Sym for 10 Cycles.

What are the 25kV operating voltage limits?

For 25kV, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

Is the K655YSR designed for submersible applications?

Yes, the K655YSR features a fully shielded, fully submersible molded rubber housing.

How is the K655YSR connected or disconnected?

It can be easily connected or disconnected using standard hand tools and equipment, but only in a de-energized state.

How to Install Elastimold K656/K676 Deadbreak Receptacles

This guide provides step-by-step instructions for the safe and proper installation of Elastimold K656/K676 series deadbreak receptacles, designed for splicing and tapping solid dielectric cables rated for 600 ampere at 15kV and 25kV. Ensure all apparatus is de-energized before beginning.

Estimated time: 1h 30m

Tools needed:

Hex wrench, Torque wrench (with 15/16" socket), Wire brush (if using aluminum cable), Cable cutting tool, Wire strippers, Rag, Approved safety solvent, 650ATY Assembly Tool or 600RRT Assembly Tool

Supplies needed:

Receptacle housings, Cable adapters, Center section (I, Wye, or H type), Aluminum holding collars, Elastimold approved lubricant, Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, No. 14 AWG copper wire (or equivalent), Electrical tape (for markers)

  1. Prepare for Installation and Ensure Safety

    Before starting, ensure all apparatus is de-energized. Inspect all parts for damage, proper rating, and compatibility. Read the entire instructions, gather all required tools and supplies, and maintain cleanliness throughout the procedure. This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Clean and Square Cable End

    Wipe the outer jacket clean for a distance of 38 inches (96.5 cm) from the cable end. Cut the cable end squarely to ensure maximum available length for crimp growth.

  3. Install ECS Grounding Device Tube (Optional)

    If an ECS grounding device is being used, slide its tube onto the cable for a distance of 38 inches (96.5 cm).

  4. Position Receptacle Housing

    Slide the receptacle housing onto the cable for a distance of 30 inches (76.2 cm).

  5. Prepare Jacketed Concentric Neutral Cable

    From the cable end, measure 13-3/4 inches (34.9 cm) and remove the cable jacket with a straight, smooth cut, taking care not to damage the neutral wires. Bend the neutral wires back and out of the way. From the cable end, measure 10-1/4 inches (26 cm) and remove the semi-con shield from the insulation with a straight, smooth, 'squared' cut, ensuring not to cut or nick the insulation. Wrap two turns of tape 1 inch (2.5 cm) from the end of the semi-con shield to serve as a marker. Bevel the end of the insulation at a 45-degree angle, approximately 1/4 inch (0.6 cm) back. Thoroughly clean the insulation with an approved safety solvent, wiping from the cable end toward the outer jacket to remove all traces of semi-conducting residue. Apply lubricant sparingly along the cable and inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until its end is flush with the tape marker.

  6. Trim Protruding Insulation and Verify Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor should measure 4 3/4 inches to 5 inches (12.1 cm - 12.7 cm). If not, redo the assembly.

  7. Assemble Aluminum Retaining Ring

    Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Using the provided hex wrench, tighten the socket head screw hand tight. Confirm the exposed conductor now measures 4 3/8 inches to 4 3/4 inches (11.1 cm - 12.1 cm). If not, redo the assembly.

  8. Prepare Conductor and Insert into Crimp Connector

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector, which contains inhibitor. Ensure the conductor is fully inserted into the crimp barrel. Measure the distance from the end of the connector to the holding collar; it must be between 6 3/4 inches and 7 inches (17.1 cm - 17.78 cm) maximum. If over 7 inches, recheck all previous work.

  9. Confirm Crimp Connector Alignment

    Prior to crimping, confirm that all components are positioned correctly and that the bolt holes in the crimp connectors are properly aligned with the bolt holes of the mating part.

  10. Crimp Connectors

    Crimp the connectors following the instructions packaged with the connectors. Rotate each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be between 6 3/4 inches and 7 inches (17.1 cm - 17.78 cm) maximum. If over 7 inches, redo all previous work.

  11. Assemble Washers and Bolt

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), then the hex-head bolt. Hand tighten. The splice and cables are now in their final positions; do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  12. Torque Bolts

    Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. (67.8 - 81.3 Nm).

  13. Lubricate Mating Surfaces

    Apply the supplied Elastimold approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing.

  14. Position Receptacle Housing and Insert Venting Rod

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  15. Complete Receptacle Housing Assembly

    Attach either the 650ATY or 600RRT assembly tool as shown in its instructions. Use the tool to slowly slide the receptacle housing over the splice section. Remove the venting rod. WARNING: If using the 600RRT tool, DO NOT place your hand on the threaded rod or guide shaft with the assembly tool in place.

  16. Final Checks and Grounding

    Check all cable adapters to ensure they are located properly. Remove all vinyl tape markers. If using an ECS grounding device, complete its installation according to its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly, taking care not to damage the eye.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.