ABB Installation Products K655YSR-F2220 15/25kV, 600 Amps, Deadbreak Straight Receptacle without Test Point. Contains Cable…
UPC: 783786324361
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage class with 600 Amp continuous current rating
- Deadbreak design eliminates test points for simplified installation/maintenance
- Fully shielded, submersible molded rubber housing for environmental protection
- Accommodates cable insulation diameters 0.640-0.820" (Type F) and conductor sizes #2 AWG to 1250 kcmil
- Includes copper compression lug, cable adapter, and retaining ring for complete connection solution
Specifications
Amperage Rating | 600 A |
Application | These Connectors allow a straight cable connection on Switchgear or Electrical Apparatus equipped with 600 Amp Bushings |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Deadbreak Straight Receptacle |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 16.98 in |
Length | 431.292 mm |
Material | Housing - EPDM-Rubber |
Material | Copper |
Series | 600 Series |
Series | K655 |
Size | Cable Insulation Diameter F - 0.640-0.820 inch |
Size | 0.640-0.820 inch (Type F insulation diameter) |
Special Features | Fully Shielded, Fully Submersible, Can be easily Connected or Disconnected in a De-Energized State |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LR-B2220
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, 0.635 inch - 0.905 inch Cable Insulation Diameter, #2 Stranded/Compressed or #1 Solid/Compact Wire Size, Copper Compression Lug. Each Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Crimp Chart and Installation Instructions.
K655YSR-L0330
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K655YSR-M0380
600 Amp, 15/25KV, Straight Receptacle without Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 700/750 or Compacted Solid 900.
M655SR-L-2270
600 Amp, 35kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size 270 - 4/0 Compressed-Stranded or 250 kcmil Compact-Solid.
K656CY-H0270
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
K656I-K0330
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.Frequently Asked Questions
What is the K655YSR's primary application?
The K655YSR provides a fully shielded, submersible cable connection on 15/25kV high-voltage “I”, “Y”, or “H” Bus. It allows straight cable connections on switchgear or electrical apparatus with 600 Amp bushings.
What are the 25kV operating voltage limits?
For 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase is 28kV.
How is the K655YSR connected or disconnected?
The K655YSR can be easily connected or disconnected using standard hand tools and equipment, but only in a de-energized state.
What is the momentary current rating?
The momentary current rating for both 15kV and 25kV voltage classes is 25kA Symmetrical for 10 cycles.
What is the impulse withstand rating for 25kV?
For the 25kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).
What is the continuous current rating for 25kV?
For the 25kV voltage class, the continuous current rating is 600 Amps.
What is the impulse withstand rating for 15kV?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).
What is the continuous current rating for 15kV?
For the 15kV voltage class, the continuous current rating is 600 Amps.
What are the 15kV operating voltage limits?
For 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What standard does the K655YSR meet?
The K655YSR meets ANSI/IEEE Standard 386, Latest Revision.
How to Install K656/K676 Series Deadbreak Receptacles
This guide provides detailed instructions for installing K656 and K676 series deadbreak receptacles, including cable preparation, crimping, and final assembly for splicing and tapping solid dielectric cables.
Estimated time: 2h
Tools needed:
Hex wrench, Torque wrench with 15/16 inch socket, Wire brush, Cable cutting tool, Wire strippers, Rag, Approved safety solvent, 650ATY assembly tool OR 600RRT assembly tool
Supplies needed:
Receptacle housings, Cable adapters, I, Wye or H Center sections (splice section), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (if used), No. 14 AWG copper wire (or equivalent), Tape (for markers, if applicable), Conductive copper strip (if applicable)
- De-energize and Inspect Apparatus
Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect all components for damage, proper rating, and compatibility with mating parts. Failure to follow these safety instructions can result in serious injury or death.
- Prepare the Cable
Wipe the outer jacket clean for 38 inches and cut the cable end squarely. Refer to the 'Special Cable Preparation Supplement' (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable) included with these instructions. Follow the specific procedure for your cable type to remove the jacket, semi-con shield, and bevel the insulation. Thoroughly clean the insulation to remove all semi-conducting residue.
- Install Receptacle Housing and Cable Adapter
If using an ECS grounding device, slide the tube onto the cable 38 inches. Slide the receptacle housing onto the cable 30 inches. Apply lubricant sparingly along the cable and inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker (if used during cable prep). Remove any protruding cable insulation, ensuring the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor, snug it against the cable adapter, and hand tighten the socket head screw with the hex wrench. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.
- Install and Crimp Connectors
Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Confirm the bolt holes in the crimp connectors are positioned to align with the mating part. Crimp the connectors according to their instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be 6 3/4 to 7 inches maximum. Repeat this step for all remaining cables.
- Assemble and Torque Bolts
Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), and then the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.
- Lubricate and Final Housing Assembly
Generously apply the supplied or ELASTIMOLD approved lubricant to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod. Use either the 650ATY or 600RRT assembly tool to slowly slide the receptacle housing over the splice section. WARNING: If using the 600RRT tool, DO NOT place your hand on the threaded rod or guide shaft. Once the housing is in place, remove the venting rod. Repeat for all remaining cables.
- Complete Grounding
Check all cable adapters to ensure they are properly located and remove any vinyl tape markers. If an ECS grounding device is used, complete its installation per its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye. Connect this wire to ground.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.