ABB - Installation Products K655YSR-L0330 - 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

ABB Installation Products K655YSR-L0330 600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter…

UPC: 783786320509


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655YSR-L0330 600 Series Deadbreak Straight Receptacle delivers a fully shielded, submersible cable connection for 15-25kV medium-voltage systems. Engineered to ANSI/IEEE Standard 386, this 600 Amp-rated receptacle supports cable insulation diameters from 1.180 inches to 1.465 inches, accommodating compressed stranded conductors up to 500 kcmil, compacted solid conductors up to 600 kcmil, and mm² compact conductors up to 250/300. The integrated aluminum compression lug ensures a secure, corrosion-resistant termination for both aluminum and copper conductors (#2 AWG to 1250 kcmil). Designed for switchgear, transformers, and electrical apparatus with 600 Amp bushings, the K655YSR-L0330 provides a deadbreak connection point that can be safely connected or disconnected in a de-energized state using standard hand tools. The receptacle meets stringent electrical ratings, including 95kV BIL impulse withstand, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand for 15kV class applications, with corresponding 140kV BIL, 45kV AC, and 84kV DC ratings for 25kV class. Optional accessories expand functionality to include visible external separation, bypass, isolation, dead-ending, grounding, testing, taps, surge arrestors, and circuit protection.
  • 600 Amp continuous current rating for medium-voltage applications
  • Supports cable insulation diameters from 1.180" to 1.465"
  • Compatible with compressed stranded (500 kcmil), compacted solid (600 kcmil), and mm² compact (250/300) conductors
  • Fully shielded, submersible molded rubber housing with 100% peroxide-cured EPDM construction
  • Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand (15kV class)

Specifications

Amperage Rating
600 A
Application
These Connectors allow a straight cable connection on Switchgear or Electrical Apparatus equipped with 600 Amp Bushings
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Compression
Environmental Conditions
All Weather Conditions
Insulation
True
Length
16.98 in
Length
431.292 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible, Can be easily Connected or Disconnected in a De-Energized State
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K655LR-J0330

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
600 Amp, 15/25KV, Straight Receptacle without Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 700/750 or Compacted Solid 900.

K655YSR-M0380

600 Amp, 15/25KV, Straight Receptacle without Test Point, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed Stranded 700/750 or Compacted Solid 900.
600 Amp, 35kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size 270 - 4/0 Compressed-Stranded or 250 kcmil Compact-Solid.

M655SR-L-2270

600 Amp, 35kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size 270 - 4/0 Compressed-Stranded or 250 kcmil Compact-Solid.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K656CY-H0270

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656I-K0330

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

K655YSR-K0280

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656I-P0410-P0410

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K656CY-G0240

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

Frequently Asked Questions

What conductor sizes are supported by the lugs?

The lugs support conductor sizes from #2 AWG to 1250 kcmil for universal aluminum and all copper connectors.

What cable insulation diameters are supported?

Supported cable insulation diameters range from 0.640 inches to 1.935 inches, corresponding to W codes F through P.

Is the K655YSR submersible?

Yes, the K655YSR features a fully shielded, fully submersible molded rubber housing.

What is the momentary current rating?

The momentary current rating for both 15kV and 25kV voltage classes is 25kA Symmetrical for 10 cycles.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amps.

What are the operating voltages for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV.

What are the operating voltages for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What cable sizes are compatible with K655YSR?

The K655YSR supports #2 AWG to 1250 kcmil for aluminum and copper conductors. It accommodates insulation diameters from 0.640 inches to 1.935 inches.

What is the K655YSR product used for?

The K655YSR provides a fully shielded, submersible cable connection on 15/25kV high-voltage “I”, “Y”, or “H” Bus. It allows a straight cable connection on switchgear or electrical apparatus with 600 Amp bushings.

What conductor sizes are supported by the lugs?

The lugs support conductor sizes from #2 AWG to 1250 kcmil for universal aluminum and all copper connectors.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides detailed instructions for installing K656 and K676 series deadbreak receptacles, including cable preparation, crimping, and final assembly for splicing and tapping solid dielectric cables.

Estimated time: 2h

Tools needed:

Hex wrench, Torque wrench with 15/16 inch socket, Wire brush, Cable cutting tool, Wire strippers, Rag, Approved safety solvent, 650ATY assembly tool OR 600RRT assembly tool

Supplies needed:

Receptacle housings, Cable adapters, I, Wye or H Center sections (splice section), Aluminum holding collars, Lubricant (supplied or ELASTIMOLD approved), Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, ECS grounding device (if used), No. 14 AWG copper wire (or equivalent), Tape (for markers, if applicable), Conductive copper strip (if applicable)

  1. De-energize and Inspect Apparatus

    Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect all components for damage, proper rating, and compatibility with mating parts. Failure to follow these safety instructions can result in serious injury or death.

  2. Prepare the Cable

    Wipe the outer jacket clean for 38 inches and cut the cable end squarely. Refer to the 'Special Cable Preparation Supplement' (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable) included with these instructions. Follow the specific procedure for your cable type to remove the jacket, semi-con shield, and bevel the insulation. Thoroughly clean the insulation to remove all semi-conducting residue.

  3. Install Receptacle Housing and Cable Adapter

    If using an ECS grounding device, slide the tube onto the cable 38 inches. Slide the receptacle housing onto the cable 30 inches. Apply lubricant sparingly along the cable and inside the cable adapter. Slide the adapter, small end first, over the cable with a twisting motion until it is flush with the tape marker (if used during cable prep). Remove any protruding cable insulation, ensuring the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor, snug it against the cable adapter, and hand tighten the socket head screw with the hex wrench. Confirm the exposed conductor now measures 4 3/8 to 4 3/4 inches.

  4. Install and Crimp Connectors

    Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector, which contains inhibitor. Confirm the bolt holes in the crimp connectors are positioned to align with the mating part. Crimp the connectors according to their instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar; it must be 6 3/4 to 7 inches maximum. Repeat this step for all remaining cables.

  5. Assemble and Torque Bolts

    Assemble the washers and bolt in the following order: flat washer against the spade contact, Belleville washer (concave side down), and then the hex-head bolt. Hand tighten the bolt. Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Do not attempt to move or reposition any part of the assembly after the bolts are tightened.

  6. Lubricate and Final Housing Assembly

    Generously apply the supplied or ELASTIMOLD approved lubricant to the outside of the cable adapter, the splice section, and the inside mating surface of the receptacle housing. Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod. Use either the 650ATY or 600RRT assembly tool to slowly slide the receptacle housing over the splice section. WARNING: If using the 600RRT tool, DO NOT place your hand on the threaded rod or guide shaft. Once the housing is in place, remove the venting rod. Repeat for all remaining cables.

  7. Complete Grounding

    Check all cable adapters to ensure they are properly located and remove any vinyl tape markers. If an ECS grounding device is used, complete its installation per its instructions. Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings, making a small loop and twisting tightly without damaging the eye. Connect this wire to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.