Overview

The ABB K656CY-H0270 is a 15-25kV 600 Series Deadbreak Separable Wye Joint Package designed for reliable three-way cable connections. This package features a test point for diagnostic capabilities and is engineered to accommodate cable insulation diameters ranging from 0.850 to 1.050 inches. The included aluminum compression lug ensures a secure and durable connection for conductors. It supports various conductor sizes, including compacted stranded 4/0 AWG, compacted solid 250 kcmil, and 125 mm² compact conductors. This deadbreak wye joint is suitable for medium voltage applications requiring safe and efficient cable termination. Its construction prioritizes electrical integrity and ease of installation in power distribution systems. The 600 Series designation signifies its adherence to specific performance standards within the ABB Installation Products catalog. The inclusion of a test point facilitates routine maintenance and troubleshooting, enhancing operational uptime. The aluminum compression lug is chosen for its conductivity and resistance to corrosion, ensuring long-term performance in challenging electrical environments. This product, with SKU K656CY-H0270, is a key component for utility and industrial power infrastructure.
  • 15-25kV voltage rating
  • 600 Series Deadbreak Separable Wye Joint (3-Way)
  • Includes test point for diagnostics
  • Accommodates cable insulation diameter 0.850" - 1.050"
  • Aluminum compression lug for conductor connection

Specifications

Amperage Rating
600 A
Application
Compact Design is suitable for small vaults and manholes
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Deadbreak Separable Wye Joint
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
37.27 in
Length
946.658 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Poles
3-Way
Series
600 Series
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Fully Shielded, Fully Submersible, 100 Percent Peroxide Cured EPDM Molded Rubber
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Separable Wye Joint
Voltage Rating
15 to 25 kV
Voltage Rating
15-25 kV
Width
8.12 in
Width
206.248 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
26.0000 L
Package Weight (Metric)
11.7940 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

656ETP-H0270-DRG-S

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. 200ECS Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656I-K0330

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.

K655YSR-K0280

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 250 /Compacted Solid 300.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656I-P0410-P0410

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. 2 X (Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

K656CY-G0240

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K656I-K0270

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

K656CY-L0330

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.

Frequently Asked Questions

What is the K656CY-HP product?

The K656CY-HP is a 15/25kV 600A Deadbreak Separable Wye Joint with a test point. It is a modular kit used to join cables in a disconnectable 3-way joint.

What standards does the K656CY-HP meet?

The K656CY-HP meets ANSI/IEEE Standard 386, Latest Revision.

Does the K656CY-HP include a test point?

Yes, the K656CY-HP includes an integral capacitive test point.

What are the components included in the kit?

Each kit contains one 3-Way Bus Bar (K656CY-BUS), two lubricants (82-08), one Installation Instruction (IS-0388), and three Straight receptacles (K655YSR).

What are the key features of this wye joint?

Key features include a compact design, fully shielded and submersible 100% peroxide cured EPDM molded rubber, reusable components, and an integral capacitive test point.

What are the fault close capabilities?

The product has a 25kA Symmetrical (Sym) rating for 10 Cycles Momentary & Fault Close for both 15kV and 25kV classes.

What is the continuous current rating?

The continuous current rating for both 15kV and 25kV voltage classes is 600 Amp.

What are the voltage ratings for the 25kV class?

For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV and maximum phase-to-phase is 28kV. It has a 140kV BIL impulse withstand.

What are the voltage ratings for the 15kV class?

For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV. It has a 95kV BIL impulse withstand.

How can I order the basic wye joint housing?

To order the basic wye joint housing only, specify K656CY-HP.

How to Install K656/K676 Series Deadbreak Receptacles

This guide provides step-by-step instructions for installing K656/K676 series deadbreak receptacles, designed to splice and tap solid dielectric cables rated for 600A at 15kV and 25kV.

Estimated time: 1h

Tools needed:

Cable stripping tool, Hex wrench, Torque wrench with 15/16 inch socket, Wire brush (for aluminum cable), 650ATY Assembly tool OR 600RRT Assembly tool, Rag, Approved safety solvent

Supplies needed:

K656/K676 Series Receptacle housings, Cable adapters, I, Wye, or H Center sections, Aluminum holding collars, ELASTIMOLD approved lubricant, Hex-head bolts, Crimp connectors, Belleville washers, Flat washers, Nylon venting rod, Electrical tape (for markers), Conductive copper strip (if using flat metallic tape shielded cable), No. 14 AWG copper wire (or equivalent, for grounding), ECS grounding device (optional)

  1. Prepare for Installation and Initial Cable Setup

    DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect all parts for damage, rating, and compatibility with mating parts. Wipe the outer jacket of the cable clean for a distance of 38 inches and cut the cable end squarely. If using an ECS grounding device, slide the ECS tube onto the cable a distance of 38 inches. Slide the receptacle housing onto the cable a distance of 30 inches.

  2. Perform Detailed Cable Preparation

    Refer to the 'SPECIAL CABLE PREPARATION SUPPLEMENT' (Part A for Jacketed Concentric Neutral Cable or Part B for Flat Metallic Tape Shielded Cable with Semi-con Shield) included with these instructions. Follow the specific procedure for your cable type to prepare the cable, including jacket removal, semi-con shield removal, insulation beveling, cleaning, lubrication, and cable adapter installation.

  3. Prepare Conductor and Crimp Connector

    Remove the protruding cable insulation, cutting it even with the end of the cable adapter. Ensure the exposed conductor measures 4 3/4 to 5 inches. Assemble the aluminum retaining ring over the conductor and snug it firmly against the cable adapter. Tighten the socket head screw hand tight with the hex wrench. Confirm the exposed conductor measures 4 3/8 to 4 3/4 inches. Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it into the crimp connector. Ensure the conductor is fully inserted. Confirm the distance from the end of the connector to the holding collar is 6 3/4 to 7 inches maximum. If over 7 inches, recheck previous work. Repeat these steps for all remaining cables to be joined.

  4. Crimp Connectors and Assemble Washers/Bolts

    Before crimping, confirm components are positioned correctly and bolt holes in the crimp connectors align with the mating part. Crimp the connectors according to their specific instructions, rotating each crimp 90 or 180 degrees. After crimping, measure the distance from the end of the connector to the holding collar. If over 7 inches, redo previous work. Assemble the washers and bolt in the order: flat washer against spade contact, Belleville washer (concave side down), hex-head bolt. Hand tighten. Do not move or reposition any part of the assembly after bolts are tightened.

  5. Torque Bolts and Lubricate Assembly

    Using a torque wrench with a 15/16 inch socket, tighten all bolts to 50 to 60 ft. lbs. Apply the supplied ELASTIMOLD approved lubricant generously to the outside of the cable adapter, the area of the splice section, and the inside mating surface of the receptacle housing.

  6. Slide Receptacle Housing and Insert Venting Rod

    Slide the receptacle housing over the cable adapter and up to the edge of the interface. Insert the nylon venting rod (supplied).

  7. Complete Receptacle Housing Installation

    If using the 650ATY Assembly Tool: Attach the tool, ensuring the “U” shaped yoke is over the splice section and the “C” shaped yoke is over the receptacle housing. Slowly raise the handle to slide the receptacle housing over the splice section. Remove the venting rod. If using the 600RRT Assembly Tool: Attach the tool. Slide the receptacle housing over the interface by turning the hex nut on either side of the tool. Remove the venting rod. WARNING: DO NOT place hand on threaded rod or guide shaft with the assembly tool in place. Repeat these steps for any remaining cables.

  8. Perform Final Checks and Grounding

    Check all cable adapters to ensure they are located properly and remove all vinyl tape markers. Complete the installation of the ECS grounding device according to its instructions (if used). Connect a short length of No. 14 AWG copper wire (or equivalent) to the grounding eyes of the housings. Make a small loop and twist tightly, taking care not to damage the eye. Connect this wire to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.