ABB Installation Products K655SR-L0320 600 Amp, 15/25kV, 600 Series Deadbreak Straight Receptacle with Cable Adapter, Lug and…
UPC: 783786312726
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Ampere current rating
- 15/25kV voltage class
- Deadbreak straight receptacle design
- Includes cable adapter, aluminum compression lug, and retaining ring
- Compatible with cable insulation diameters from 1.180" to 1.465"
Specifications
Amperage Rating | 600 A |
Conductor Range | 450 COMPR/STR kcmil |
Connection | Compression |
Connection Type | Compression Lug |
Current Rating | 600 A |
Insulation | EPDM Rubber |
Material | Aluminum |
Material | EPDM-Rubber |
Series | 600 Series |
Size | 1.180 inch to 1.465 inch |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Straight Receptacle |
Voltage Rating | 15/25 kV |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-J0330
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size kcmil Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
775ETPSP-P2410
35 kV, 900 Amps, Window-Op (Test and Ground Connector Kit), with Factory Installed Copper Stud, No Capacitive Test Point, Cable Insulation Diameter P - 1.725 to 1.935 inch, Connector Size 410 - 1000 Stranded/Compressed kcmil. Includes Crimp Chart and Instruction Sheets.
168RLR-J5270
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG Compressed Stranded 4/0 or Solid Compact 250 kcmil or mmSquared 126.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes Elbow Connector Housing, Long Bi-Metal Compression Lug, Probe Wrench, Probe, Hose Clamp, Crimp Chart, Installation Instructions and Tube of Lubricant.
K656LR-H2250-SG3
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K151SR-A2240
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid Compact 2/0 or 53.49 mm2. Includes Straight Receptacle Housing, Receptacle Pin Connector, Lubricant, Installation instructions and Crimp Chart
K151SP-C2240
15kv 200 Amp Straight Plug No Test Point, No Seal, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid Compact 2/0 or 53.49 mm2.
262LR-D5240-S
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 9.03 inches tall, 2.097 inch diameter. Includes Cold Shrink-Fit Jacket Seal KitFrequently Asked Questions
What is the acceptable cable insulation diameter range?
The receptacle is designed for cable insulation diameters between 1.180 inches and 1.465 inches.
What type of lug is included with this receptacle?
An aluminum compression lug is included with the ABB K655SR-L0320 receptacle.
What is the current rating of the K655SR-L0320?
The ABB K655SR-L0320 has a current rating of 600 Amps.
What is the maximum voltage rating for this receptacle?
The ABB K655SR-L0320 receptacle has a voltage rating of 15/25kV.
What conductor sizes are compatible with this receptacle?
This receptacle supports 320-450 kcmil compressed-stranded or 500/550 kcmil compacted solid aluminum conductors.
How to Install the K655SR/M655SR Deadbreak Straight Receptacle
This guide provides step-by-step instructions for the safe and proper installation of the K655SR/M655SR Deadbreak Straight Receptacle, connecting it to an ANSI-386 600 amp bushing.
Estimated time: 1h 30m
Tools needed:
5/8-11 tap (if applicable), Torque wrench with 15/16 socket, Hex wrench (supplied), Wire brush (for aluminum cable), Wire strippers, Crimp tool, Multimeter
Supplies needed:
Receptacle housing, Bushing adapter, Cable adapter, Aluminum holding collar, Hex head bolt, Crimp connector, Belleville washer, Flat washer, Nylon venting rod, Lubricants (supplied or ELASTIMOLD approved), Brass bolt, Bushing converter contact, Tape marker, No. 14 AWG copper wire (or equivalent), Suitable connector (for neutral and grounding wires), Loctite, Hose Clamp (M655SR for 35kV only)
- De-energize and Prepare Bushing
DANGER: De-energize all apparatus before beginning installation. This product must be installed by competent personnel trained in high voltage safety practices. If a stud is present in the apparatus bushing, remove it and re-tap the hole using a 5/8-11 tap. Clean and lubricate the apparatus bushing and bushing converter interface. Assemble the bushing converter onto the apparatus bushing. Apply 3-4 drops of Loctite to the brass bolt threads. Assemble the contact adapter with the bolt hole facing out, using the 5/8” brass bolt. Torque to 60 ft.-lbs.
- Prepare Cable and Receptacle Housing
Train the cable end and cut it squarely. Unwrap concentric neutral wires (if applicable) 30” (76cm), bend, and fold them back; do not cut. Wipe the outer jacket clean for 38” (96.5cm) or up to the neutral wires. Slide the receptacle housing onto the cable 30” (76cm). Remove the semi-con shield and install a tape marker 10-1/4” (26.04cm) to 11-1/4” (28.58cm) from the cable end. Do not cut or nick the cable insulation.
- Install Cable Adapter and Expose Conductor
Bevel the cable insulation end at a 45˚ angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the tape marker. Remove protruding cable insulation by cutting it even with the cable adapter end. Do not cut or nick the cable adapter or conductor. Exposed conductor length must be 4 3/4” – 5” (12.06cm – 12.7cm); otherwise, redo assembly. Position the holding collar over the conductor, flush against the cable adapter, and tighten the setscrew with the supplied hex wrench.
- Prepare and Crimp Connector
Remove the protective cap from the crimp connector. If using aluminum cable, wire brush the conductor and immediately insert it fully into the crimp connector (contains inhibitor). Measure the distance from the connector end to the holding collar; if over 7” (17.8cm), redo previous work. Confirm component orientation and that the crimp connector bolt hole aligns with the contact adapter bolt hole. Crimp the connectors following their instructions, rotating each crimp 90˚. After crimping, re-measure the distance; if over 7” (17.8cm), redo previous work.
- Final Assembly and Grounding
Assemble washers and bolt: Flat washer against spade contact, Belleville washer (concave side down), hex-head bolt. Hand tighten. Torque to 50-60 ft.-lbs with a 15/16 socket. Do not move assembly after tightening. Apply supplied or ELASTIMOLD approved lubricant generously to the cable adapter and bushing adapter. DO NOT SUBSTITUTE. Slide receptacle housing over cable adapter to interface edge. Insert supplied nylon venting rod. Slide housing onto bushing converter until fully seated. Remove venting rod. Connect No. 14 AWG copper wire to grounding eye. Gather neutral wires and connect with grounding wire. For 35kV only, position hose clamp between locator bumps and tighten until an audible click.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.