Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655L3-K0240 - 15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

ABB Installation Products K655L3-K0240 15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.090 inch to 1.310…

UPC: 783786023790


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655L3-K0240 is a 15/25kV 600A 3-way deadbreak L-kit designed for medium-voltage power distribution systems. This kit enables efficient line splitting into two branches while maintaining full electrical integrity, ideal for in-line, out, and tap applications. The deadbreak design allows safe connection and disconnection under de-energized conditions using standard hand tools, eliminating arc hazards during maintenance. Each kit includes three K655LR elbow connectors, two K650BIP basic insulating plugs, and two K651CP connecting plugs, with installation instructions provided. The fully shielded, fully submersible molded rubber housing ensures reliable performance in harsh environments, meeting ANSI/IEEE Standard 386 requirements. The 100% peroxide-cured EPDM construction delivers superior insulation and conductive properties with long-term durability. Voltage ratings include 8.3kV phase-to-ground and 14.4kV phase-to-phase for 15kV class, with 16.2kV phase-to-ground and 28kV phase-to-phase for 25kV class. The kit supports 600A continuous current with 25kA symmetrical momentary rating (10 cycles). Optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, and capacitive voltage testing via the insulating plugs. Cable insulation diameter compatibility ranges from 1.090 to 1.310 inches, suitable for 1/0 AWG compressed stranded or 2/0 AWG compacted solid conductors. The aluminum compression lug ensures high conductivity and corrosion resistance. This deadbreak L-kit is essential for utility, industrial, and commercial medium-voltage systems requiring safe, reliable branching connections.
  • 15/25kV voltage rating with 600A continuous current capacity
  • 3-way configuration for line splitting into two branches
  • Deadbreak design enables safe de-energized connection/disconnection
  • Fully shielded, submersible molded rubber housing with EPDM construction
  • Supports cable insulation diameters from 1.090 to 1.310 inches

Specifications

Amperage Rating
600 A
Application
Used to split one line into two on in, out, tap and using the two insulating plugs as test points allows for capacitive voltage testing
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Compression
Environmental Conditions
Fully Submersible
Insulation
True
Length
10.87 in
Length
276.098 mm
Material
Housing - EPDM-Rubber
Special Features
No Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak 3-Way L Kit
Voltage Rating
15 to 25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
600 Amp, 15/25kV 600 Series Deadbreak 3-Way L-Kit, 2 X ( Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. ) 1 X ( Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. )

K655L3-2M0400-K0310

600 Amp, 15/25kV 600 Series Deadbreak 3-Way L-Kit, 2 X ( Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500. ) 1 X ( Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240. )
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655LINKCLRN0410ADRG

600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655CCP-M0380

15/25kV, 600 Amp, no test point, Combo T Connecting Plug with Stud, Cable Adapter and Lug Kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15/25kV 600 Series Deadbreak 4-Way L-Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.

K655L4-H0270-S

15/25kV 600 Series Deadbreak 4-Way L-Kit, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.

K655L3-LM0360

15/25kV 600 Series Deadbreak 3-Way L-Kit, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

655LINKCLRM0410ADRG

600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

274ELR-6689-230-S

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

Frequently Asked Questions

What is the voltage rating of the K655L3-K0240 L-kit?

The K655L3-K0240 L-kit has a voltage rating of 15/25 kV.

What cable insulation diameters does this L-kit support?

This L-kit supports cable insulation diameters ranging from 1.090 inches to 1.310 inches.

What type of connection does the K655L3-K0240 offer?

The K655L3-K0240 offers a deadbreak connection type.

What conductor sizes are compatible with this L-kit?

This L-kit is compatible with 1/0 AWG compressed stranded or 2/0 AWG compacted solid conductors.

What material is the compression lug made of?

The compression lug is made of aluminum.

How many poles does this L-kit have?

This L-kit has a 3-pole configuration.

How to Install the 600/900 Series Deadbreak Connecting Plug

This guide provides step-by-step instructions for the safe installation and connection of the 600/900 Series Deadbreak Connecting Plug with its mating part. Ensure all apparatus are de-energized and only competent personnel trained in high voltage electrical equipment perform this installation.

Estimated time: 45m

Tools needed:

Torque Wrench, 600ATM or 3/8” Hex Bit Socket, Wire strippers, Cleaning supplies

Supplies needed:

600/900 Series Deadbreak Connecting Plug, Lubricant (supplied, DO NOT SUBSTITUTE), Mating Plug Device (e.g., Elbow, Bushing Extender), Stud (if not pre-installed in mating device), No. 14 AWG (2.5mm) copper wire (if applicable)

  1. Prepare the Mating Plug Device

    If the mating plug device (elbow, bushing extender, vault stretcher, or elbow end module) is not equipped with a stud, hand tighten the stud into the mating plug device. Ensure the stud is threaded in until the start of the flats are below the contact surface.

  2. Clean and Lubricate Parts

    Clean both the connecting plug and its mating part as indicated in the diagrams. Lubricate both parts thoroughly with the lubricant supplied in the package. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the products. Be sure to keep all surfaces clean during this process.

  3. Connect and Torque the Plug

    Push the connecting plug firmly into the elbow, bushing extender, vault stretcher, or elbow end module, ensuring the threads engage. Hold the contact of the connecting plug against the contact surface of the mating part. Use a 600ATM or a 3/8” hex bit socket with a torque wrench and tighten, exerting 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.

  4. Ground the Connecting Plug (If Applicable)

    If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye. Connect the other end of the wire securely to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.