ABB - Installation Products 655LINKCLRM0410ADRG - 600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000.

ABB Installation Products 655LINKCLRM0410ADRG 600 Amp, 15kV, Deadbreak RetroFit Cam-Op Connector Kit with Insulated Cap, Cable…

UPC: 783786275168


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Series 600 Amp, 15kV Deadbreak RetroFit Cam-Op Connector Kit (SKU: 655LINKCLRM0410ADRG) is designed for reliable cable terminations in medium-voltage applications. It features a deadbreak connection type, ensuring a secure and safe interface. The kit includes an insulated cap for enhanced safety and protection. Engineered for cables with an insulation diameter ranging from 1.370 inches to 1.630 inches, this connector accommodates a substantial range of cable sizes. The aluminum compression lug is suitable for compressed stranded conductors up to 1000 kcmil, providing robust electrical conductivity. The Cam-Op mechanism facilitates easy and secure connection and disconnection, simplifying maintenance and installation procedures. This connector is a key component for power distribution systems, substations, and industrial facilities requiring dependable 15kV power handling. ABB's commitment to quality in their Installation Products division ensures this connector meets stringent operational requirements. Key specifications include: * **Voltage Rating:** 15 kV * **Current Rating:** 600 A * **Cable Insulation Diameter Range:** 1.370" - 1.630" * **Conductor Size (Compressed Stranded):** Up to 1000 kcmil * **Connection Type:** Deadbreak * **Material:** Aluminum * **Series:** 600 Series This RetroFit kit allows for efficient upgrades and replacements of existing connector systems, offering a practical solution for maintaining operational integrity. The aluminum construction ensures good conductivity and durability for long-term service life.
  • 600 Amp, 15kV Voltage Rating
  • Deadbreak Connection Type with Insulated Cap
  • Accommodates Cable Insulation Diameter: 1.370" - 1.630"
  • Aluminum Compression Lug for 1000 kcmil Conductors
  • ABB 600 Series RetroFit Cam-Op Connector Kit

Specifications

Amperage Rating
600 A
Application
External Visible Break, Testing, Grounding and Isolation
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Insulation
True
Material
EPDM-Rubber
Size
20.50 inches from edge of Lever to Bushing Flange
Special Features
Easily Installed or Removed by Hotstick Operation of the Cam Action Disconnect Lever
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Retro Cam_OP Connector Kit
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )

K656CYP0410P0410P041

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, with 3 X ( Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1000. )
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.

274ELR-6689-230-S

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch.

168ELR-7495-260

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

168ELR-88110-250

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. 200ECS Jacket Seal Included.

167ELR-6689-240-S

200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.665 inch to 0.895 inch. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. 200ECS Jacket Seal Included.
200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273ELR-7495-240

200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

755L2-J0230

600 Amp, 35kV, 600 Series Deadbreak 2-Way L-Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

167ELR-6689-210

15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

Frequently Asked Questions

What types of conductor materials are supported?

The kit supports Aluminum, Copper, and Bi-metal conductors.

What type of connectors does the CAM-OP system use?

The CAM-OP systems utilize pin and socket connectors.

How is the CAM-OP Connector Kit installed or removed?

It is easily installed or removed by hotstick operation of the cam action disconnect lever.

Which industry standards does the connector kit meet?

The connector kit meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the connector kit?

The CAM-OP Connector Kit has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this kit?

The maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase voltage is 14.4kV for the 15kV Voltage Class.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What are the applications of the CAM-OP Connector Kit?

It's used for 600 Series CAM-OP Deadbreak connector systems, enabling hotstick operations for de-energized primary feeder or network circuits. It allows for visible break, testing, grounding, and isolation.

What is the impulse withstand rating (BIL) of the kit?

The kit has a 95kV BIL (Basic Impulse Level) for impulse withstand, measured with a 1.2 x 50 microsecond wave.

What is the DC 15-minute withstand voltage?

The DC 15-minute withstand voltage rating is 53kV DC.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe installation and setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.

Estimated time: 1h

Tools needed:

Torque wrench, Socket wrench (1 inch hex), Hot stick, Wire strippers, 600ATM Operating Tool

Supplies needed:

ELASTIMOLD supplied lubricant, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Prepare for Installation and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, proper rating, and compatibility with mating components. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Read all instructions thoroughly before starting.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the specific installation instructions provided with the elbow. Ensure it is positioned to properly align with the stand-off plug or apparatus bushing.

  3. Install the Bushing Extender

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the bushing extender onto the apparatus bushing. Insert the retainer contact into the bushing extender and thread it into the apparatus bushing using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  4. Install the 600 Amp Elbow onto the Epoxy Standoff Plug

    Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the elbow onto the epoxy standoff plug. Insert the retainer contact into the 600 amp elbow through the hole in the compression lug and thread it into the epoxy standoff plug using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender at a dimension of 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.

  6. Position and Secure the Elbow in the Alignment Bracket

    Position the elbow in the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert and Engage the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, engaging the roller pin and moving the Link inward. Continue moving lever arms until they are perpendicular to the alignment bracket leg.

  8. Ground the System and Install Mating Products

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point. Install the desired 200 amp mating product onto the Link's 200 amp interface according to its specific instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.