Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655ETP-L0380-DRG - 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Insulated Cap.

ABB Installation Products K655ETP-L0380-DRG 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 1.180…

UPC: 783786979103


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655ETP-L0380-DRG is a 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit designed for reliable electrical connections. This kit is engineered to accommodate cable insulation diameters ranging from 1.180 inches to 1.465 inches, ensuring compatibility with a defined range of medium-voltage cables. It features an aluminum compression lug for secure conductor termination. The connector supports conductor sizes of 700/750 kcmil for compressed stranded conductors and 900 kcmil for compacted solid conductors. Included with the kit is an insulated cap, providing an essential layer of safety and protection during testing and grounding procedures. This component is critical for safe and effective maintenance, testing, and grounding operations in electrical distribution systems. The UNSPSC code for this product is 39121421. Manufacturer: ABB - Installation Products. SKU: K655ETP-L0380-DRG.
  • 25kV voltage rating
  • 600 Amp current rating
  • Deadbreak, Test, and Ground functionality
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Aluminum compression lug for 700/750 kcmil (compressed stranded) or 900 kcmil (compacted solid) conductors

Specifications

Amperage Rating
600 A
Application
600 Amps, 25kV
Color
Black
Conductor Range
700 to 750 STR/COMPR kcmil , 900 SOL/COMPT kcmil
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.180 inch to 1.465 inch
Special Features
Includes Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655ETP-M5380

600 Amp, 25KV, DeadBreak, Elbow Connector, Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing AC04 - 750-1250 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.

K655VSL2-MAC04

15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing AC04 - 750-1250 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.
15kv, Loadbreak Elbow with Test Point and Sealing Kit. Cable Insulation Diameter .805 to 0.905 inches. Bi-Metal Compression Connector. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Cold-Shrinkable Jacket Seal.

162LR-C5260-S

15kv, Loadbreak Elbow with Test Point and Sealing Kit. Cable Insulation Diameter .805 to 0.905 inches. Bi-Metal Compression Connector. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Cold-Shrinkable Jacket Seal.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300. No Sealing Kit.

K656LR-L0280

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300. No Sealing Kit.
15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid 250 or mm2 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-G2270-SG3

15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid 250 or mm2 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Stranded/Compressed or #3 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

162LR-C5200-SG3

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Stranded/Compressed or #3 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp Deadbreak Elbow with Test Point and with SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter J - 0.980 to 1.180 inch. Aluminum Compression Lug, Conductor Size 300 - 350 kcmil Stranded/Compressed or 400 kcmil Solid/Compact.

K656LR-J0300-SG3

15/25kV, 600 Amp Deadbreak Elbow with Test Point and with SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter J - 0.980 to 1.180 inch. Aluminum Compression Lug, Conductor Size 300 - 350 kcmil Stranded/Compressed or 400 kcmil Solid/Compact.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

161LR-B-5220-SG3

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

Frequently Asked Questions

What components are included in the kit?

Each kit contains an Elbow Housing, Elbow Tap Plug, Insulated Cap, Cable Size Adapter, Compression Lug, Stud, Silicone Lubricant, Crimp Chart, and Instruction Sheets.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 Cycles.

What is the corona extinction voltage?

The corona extinction voltage is 21.5kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage?

The DC 15-minute withstand voltage is 84kV.

What is the AC one-minute withstand voltage?

The AC one-minute withstand voltage is 45kV.

What is the impulse withstand rating (BIL)?

The impulse withstand (BIL) rating is 140kV (1.2 x 50 microsecond wave).

What standard does this product meet?

The WINDOW-OP Connector Kit meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating?

The connector kit has a continuous current rating of 600 Amps.

What is the maximum operating voltage?

The maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase voltage is 28kV for the 28kV Voltage Class.

What is the product's primary application?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for an internal visible break.

How to Install the K655ETP-L0380-DRG Insulated Cap with Ground Lead

This guide provides step-by-step instructions for the safe installation of the K655ETP-L0380-DRG Insulated Cap with Ground Lead onto a 15kV class loadbreak bushing interface, ensuring proper insulation, shielding, and watersealing.

Estimated time: 15m

Tools needed:

Hotstick

Supplies needed:

Insulated Cap with Ground Lead, Lubricant

  1. Prepare for Installation and De-energize Apparatus

    Before starting, ensure all apparatus is de-energized. Inspect the contents of the package for completeness and damage, and verify proper fit with mating products. Gather all required tools and maintain a clean work area. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.

  2. Connect the Electrostatic Grounding Wire

    Connect the free end of the electrostatic grounding wire from the insulated cap to the system ground. Leave sufficient slack in the wire to allow for hot-stick operation of the insulated cap. Ensure the grounding wire is positioned so it will not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach it without first pulling the insulated cap off the bushing with the hotstick.

  3. Lubricate the Insulated Cap

    Remove the protective cover from the insulated cap. Apply only the supplied lubricant or ELASTIMOLD approved lubricants to the cap's internal mating surface. Do not substitute lubricants, as others may be harmful. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when the cap is not in use.

  4. Install the Insulated Cap onto the Bushing

    Firmly attach a full insulated hotstick to the pulling eye of the insulated cap. Carefully insert the male contact of the insulated cap into the loadbreak bushing. Push the cap home with a fast, firm, and straight motion until it is fully mated and the locking ring is seated. Once fully seated, detach the hotstick from the insulated cap.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.