ABB Installation Products 162LR-C5260-S 15kv, Loadbreak Elbow with Test Point and Sealing Kit. Cable Insulation Diameter .805 to…
UPC: 075114358866
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV class loadbreak elbow with integrated test point for non-invasive voltage detection
- Supports cable insulation diameters 0.805"–0.905" and conductor sizes 260 kcmil to 3/0 AWG stranded/compressed or 4/0 AWG solid/compact
- Bi-metal compression connector for copper and aluminum conductors with mechanical/electrical integrity
- Cold-shrinkable jacket seal provides moisture-tight, track-resistant interface; no heat or specialized tools required
- Compatible with standard 15kV loadbreak bushings in vaults, pad-mounted gear, or direct-buried applications
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point. Includes Sealing Kit |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-D5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
K656LR-L0280
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300. No Sealing Kit.
K656LR-G2270-SG3
15/25 KV, Elbow Connector with Test Point, 600 Amp, Dead Break, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid 250 or mm2 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
162LR-C5200-SG3
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, Conductor Size #4 Stranded/Compressed or #3 Solid/Compact, Bi-Metal Compression Lug. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
K656LR-J0300-SG3
15/25kV, 600 Amp Deadbreak Elbow with Test Point and with SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring. Cable Insulation Diameter J - 0.980 to 1.180 inch. Aluminum Compression Lug, Conductor Size 300 - 350 kcmil Stranded/Compressed or 400 kcmil Solid/Compact.
161LR-B-5220-SG3
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
755DLR-J0240
600 Amp, 35KV, Direct Test Elbow, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Compacted/Solid 2/0.
755DLR-P0380
35kV 600 Series Deadbreak Direct Test Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.Frequently Asked Questions
What are the voltage ratings for this elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
Does the elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
What standards does the elbow comply with?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification.
Does it have an improved seal system?
Yes, the enhanced Elastimold elbow features an improved seal system for both traditional and jacket seal options.
What is the operational benefit with Elastimold bushings?
When used with Elastimold bushings, the elbow provides lifetime ease of operation and a non-stick interface.
Is an integral jacket seal available for the elbow?
Yes, the enhanced Elastimold elbow offers an optional integral jacket seal.
Does the elbow offer grounding options?
Yes, the enhanced Elastimold elbow includes dual grounding eye positions.
What type of pulling eye does the elbow feature?
The elbow features a robust stainless-steel pulling eye, promoting durable hotstick control.
Does the elbow have a no-stick interface?
Yes, the enhanced Elastimold elbow features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
How does the elbow ensure proper switching?
The elbow incorporates rigid probe support to ensure proper switching operations and easy probe installation.
How to Install Elastimold 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various UD cables, including cable preparation, lug attachment, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Cable cutting tools, Wire brush, Crimp tool, Wrench (for probe), Hotstick, Suitable sensing device (for 162LR voltage test)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate ground connector, Cold shrink tube (if using sealing kit), Conductive copper tape (if using copper tape shield kit), Vinyl tape, Silicone lubricant (for test point cap)
- De-energize and Inspect Components
DANGER: Ensure all apparatus is de-energized during installation or removal of parts, except for test point caps and indicators. Failure to follow these instructions will result in serious or fatal injury. Inspect all package contents to confirm they are complete and undamaged. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; it should turn freely for approximately four turns before becoming snug. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare Cable Outer Jacket and Neutral/Shield
Train the cable to ensure sufficient slack for ease of operation. Based on your specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the outer jacket and neutral/shield according to the provided diagrams and measurements in the full instructions. For example, remove 9-5/8 inches (240mm) of the outer jacket for jacketed cables. For copper tape shield cables, remove 7-1/8 inches (180mm) of the copper tape shield and wrap conductive copper tape over the end. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable, loose end first.
- Prepare Conductor and Insulation, Install Compression Lug
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart supplied with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 6-7/8 inches (175mm) back from the cable end. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to Bushing Plug
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion. Use sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
- Perform Voltage Test (162LR Only)
If installing a 162LR connector with a test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious injury. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.