Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655ETP-J0280-DRGSG3 - 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 250 /Compacted Solid 300 kcmil. With Insulated Cap and Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

ABB Installation Products K655ETP-J0280-DRGSG3 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit. Cable Insulation Diameter 0.980…

UPC: 075114420112


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655ETP-J0280-DRGSG3 is a 25kV, 600 Amp Deadbreak, Test and Ground Connector Kit designed for reliable electrical connections in medium-voltage applications. This kit features an aluminum compression lug suitable for conductor sizes ranging from 250 kcmil compressed stranded to 300 kcmil compacted solid. The cable insulation diameter compatibility is between 0.980 inches and 1.180 inches, ensuring a secure fit for a range of cable types. Engineered for robust performance, the K655ETP kit includes an insulated cap for deadbreak termination and a cold-shrinkable seal. This seal is integrated with a copper braid for effective conductivity and grounding, along with a constant force spring to maintain consistent pressure and ensure long-term connection integrity. The aluminum construction of the compression lug provides excellent electrical conductivity and corrosion resistance. This connector kit is part of the ABB K655ETP series, known for its dependable performance in power distribution systems. The 25kV voltage rating and 600A current rating make it suitable for substations, industrial facilities, and utility power networks. The inclusion of test and ground capabilities enhances operational safety and maintenance procedures. Key Specifications: - SKU: K655ETP-J0280-DRGSG3 - Manufacturer: ABB - Installation Products - Voltage Rating: 25 kV - Current Rating: 600 A - Cable Insulation Diameter: 0.980" to 1.180" - Conductor Size: 250 kcmil (Compressed Stranded) / 300 kcmil (Compacted Solid) - Lug Material: Aluminum - Connection Type: Compression Lug - Features: Insulated Cap, Cold-Shrinkable Seal, Copper Braid, Constant Force Spring - Series: K655ETP
  • 25kV voltage rating for medium-voltage applications
  • 600 Amp continuous current rating
  • Accommodates cable insulation diameters from 0.980" to 1.180"
  • Aluminum compression lug for 250/300 kcmil conductors
  • Includes insulated cap, cold-shrinkable seal with copper braid, and constant force spring

Specifications

Amperage Rating
600 A
Application
600 Amps, 25kV
Color
Black
Conductor Range
COMPR/STR 250 kcmil , COMPT/SOL 300 kcmil
Connection
Compression
Insulation
True
Material
EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.18 inch
Special Features
Includes Seal and Insulated Cap
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Elbow Connector
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.

K655LR-H0240

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0.
35kV, 900 Amp, Deadbreak, Compact 4-Way (H) Insulated BUS Bar with Test Point, with Spiking Aid. Includes Conductive Jacket, Painted Pin, Lube, and Instruction Sheet

M676CHSL-BUS

35kV, 900 Amp, Deadbreak, Compact 4-Way (H) Insulated BUS Bar with Test Point, with Spiking Aid. Includes Conductive Jacket, Painted Pin, Lube, and Instruction Sheet
25kV, 900 Amp, Deadbreak, Compact 4-Way (H) Insulated BUS Bar with Test Point and Spiking Aid. Includes Conductive Jacket and Insert, Painted Pin, Lube, Warning Tag, and Instruction Sheet

K676CHSL-BUS

25kV, 900 Amp, Deadbreak, Compact 4-Way (H) Insulated BUS Bar with Test Point and Spiking Aid. Includes Conductive Jacket and Insert, Painted Pin, Lube, Warning Tag, and Instruction Sheet
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed Stranded 450 or Compacted Solid 500/550.

K656CY-L0320

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil, Compressed Stranded 450 or Compacted Solid 500/550.
25kV, 900 Amp, Deadbreak, Separable Cable Joint, 1-Way Insulated Bus Bar with Test Point, With Spiking Aid.

K676ISL-BUS

25kV, 900 Amp, Deadbreak, Separable Cable Joint, 1-Way Insulated Bus Bar with Test Point, With Spiking Aid.
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded or 4/0 Solid AWG Wire Size, Bi-Metal Compression Lug

161LRJS-D5260

15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded or 4/0 Solid AWG Wire Size, Bi-Metal Compression Lug
15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0. Cold-Shrinkable Jacket Seal Included.

K656I-H0260-S

15-25kV 600 Series Deadbreak Separable Straight Joint Package (2-Way) with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0. Cold-Shrinkable Jacket Seal Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0.

K151SP-C0260

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0.

Frequently Asked Questions

What is the purpose of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for a visible internal break.

What is the maximum operating voltage for this connector?

The maximum phase-to-ground operating voltage is 16.2kV, and the maximum phase-to-phase voltage is 28kV for the 28kV Voltage Class.

What is the continuous current rating of the connector?

The connector has a continuous current rating of 600 Amps.

Which industry standards does this connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating (BIL)?

The Basic Impulse Level (BIL) impulse withstand rating is 140kV (1.2 x 50 microsecond wave).

What are the AC and DC withstand voltage ratings?

The connector has a 45kV AC one-minute withstand rating and an 84kV DC fifteen-minute withstand rating.

What is the purpose of WINDOW-OP connectors?

WINDOW-OP connectors allow direct testing and grounding without cable movement. They are ideal for equipment with viewing windows for a visible internal break.

What is the impulse withstand rating (BIL)?

The Basic Impulse Level (BIL) impulse withstand rating is 140kV (1.2 x 50 microsecond wave).

What are the AC and DC withstand voltage ratings?

The connector has a 45kV AC one-minute withstand rating and an 84kV DC fifteen-minute withstand rating.

Which industry standards does this connector meet?

The connector meets ANSI/IEEE Standard 386, Latest Revision.

How to Install the K655ETP-J0280-DRGSG3 Insulated Cap with Ground Lead

Instructions for installing and removing the K655ETP-J0280-DRGSG3 insulated cap with ground lead on a loadbreak bushing interface.

Estimated time: 30m

Tools needed:

Hotstick, Screwdriver (for system ground connection, if applicable)

Supplies needed:

Insulated Cap with Ground Lead, Lubricant (supplied or ELASTIMOLD approved), Mounting screws (if applicable for system ground)

  1. Connect the electrostatic grounding wire

    Connect the free end of the electrostatic grounding wire to the system ground. Ensure there is enough slack for hot-stick operation. CAUTION: Train the grounding wire so it does not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.

  2. Prepare the insulated cap

    Remove the protective cover from the insulated cap. Lubricate the cap's internal mating surface using only the supplied lubricant or ELASTIMOLD approved lubricants. DO NOT SUBSTITUTE. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when not in use.

  3. Install the insulated cap

    Firmly attach the hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing. Push home with a fast, firm, straight motion, ensuring it is fully mated and the locking ring is seated. Detach the hotstick from the insulated cap.

  4. Remove the insulated cap

    Attach the hotstick to the pulling eye. Before pulling, rotate the insulated cap clockwise while in the mated position to break surface friction. Pull the receptacle off with a fast, firm, straight motion. Remove the electrostatic grounding wire of the insulated cap from the system ground. Replace the protective cover on the insulated cap to keep its internal surface clean.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.