The ABB K655BCCP is a ComboT Connecting Plug designed for 15/25kV applications, rated for 600 Amps. This specific model, SKU K655BCCP, is manufactured by ABB's Installation Products division and features a stud connection for secure electrical termination. Constructed from aluminum, this connecting plug is engineered for reliable performance in industrial electrical systems. It is a key component for connecting high-voltage equipment, facilitating power distribution and management within substations, industrial facilities, and utility networks. The absence of a test point indicates a specific design choice for applications where direct testing through the connector is not required, simplifying the overall connection and potentially reducing points of failure. This product aligns with UNSPSC code 26121630, categorizing it within electrical connectors and accessories. ABB's reputation for quality and robust electrical solutions ensures that the K655BCCP meets stringent industry standards for safety and operational efficiency. Its aluminum construction offers good conductivity and corrosion resistance, suitable for various environmental conditions encountered in power infrastructure. The 600 Amp rating makes it suitable for medium-voltage power circuits where substantial current handling is necessary.
  • 15/25kV voltage rating for medium-voltage applications
  • 600 Amp current capacity for substantial power handling
  • ComboT Connecting Plug design
  • Features a stud connection for secure termination
  • Constructed from durable aluminum

Specifications

Application
400 Amps
Connection Type
ComboT Connecting Plug with Stud
Current Rating
600 A
Material
Aluminum
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Combo-T Connecting Plug
Voltage Rating
15/25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.8400 L
Package Weight (Metric)
2.1950 kg
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

K655BLR-K0330

600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
15/25kV 600 Series Deadbreak Insulated Parking Bushing, Factory assembled Stud, which is not field removable.

K650SOP-SP

15/25kV 600 Series Deadbreak Insulated Parking Bushing, Factory assembled Stud, which is not field removable.
15/25kV 600 Series Deadbreak Insulated Plug (with Cap). Material Epoxy, Length 4.5 inch, Widest Diameter 3 inch. - Pack of 20

K650BIP-20 PACK

15/25kV 600 Series Deadbreak Insulated Plug (with Cap). Material Epoxy, Length 4.5 inch, Widest Diameter 3 inch. - Pack of 20
Elbow Tap Plug, 200 Amp Load Break 25kv, White Silicone Band

K650ETP-WB

Elbow Tap Plug, 200 Amp Load Break 25kv, White Silicone Band
15/25kV 600 Series Deadbreak Reducing Tap Well, 600/200 Amps. 20 pack.

K650RTW-20 PACK

15/25kV 600 Series Deadbreak Reducing Tap Well, 600/200 Amps. 20 pack.
15/25kV, 900 Amp, Deadbreak, Insulating Plug with Cap, with Loose Stud.

K675BIPS

15/25kV, 900 Amp, Deadbreak, Insulating Plug with Cap, with Loose Stud.
600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. Pack of 15.

K650CP-15 PACK

600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. Pack of 15.
15/25kV, 900Amp, Deadbreak, Stick-Op Bushing Adapter.

K675BEA2

15/25kV, 900Amp, Deadbreak, Stick-Op Bushing Adapter.

Frequently Asked Questions

What is the voltage rating of the ABB K655BCCP?

The ABB K655BCCP has a voltage rating of 15/25kV.

What is the current capacity of this connecting plug?

This connecting plug is rated for 600 Amps.

What material is the ABB K655BCCP made from?

The ABB K655BCCP is constructed from aluminum.

Does this connecting plug have a test point?

No, this specific model, the K655BCCP, does not have a test point.

What type of connection does the K655BCCP use?

The K655BCCP features a stud connection.

How to Install K655/K656CCP Deadbreak Elbow Connectors

Install K655/K656CCP Deadbreak Elbow Connectors, providing fully shielded, submersible deadfront cable connections for 15kV or 25kV class systems. Ensure all apparatus is de-energized and follow safety protocols for high voltage equipment.

Estimated time: 1h 30m

Tools needed:

Wire brush, 600 ATM assembly tool, Hotstick, Crimping tool, Capacitive voltage sensing device

Supplies needed:

K655/K656CCP Deadbreak Elbow Connector Kit, Vinyl plastic tape, Tape retainer, Tape marker, Grounding wire (min. No. 14 AWG Copper equivalent), Suitable grounding connector, Silicone grease, HV insulated cap(s) or connector(s), DR(G), GLR, or LR mating connector

  1. De-energize and Position Cable

    WARNING: All apparatus must be de-energized during installation. Position the cable in its final assembled position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product.

  2. Clean Cable and Prepare Outer Jacket

    Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket to a dimension of 12 3/4” (324mm) as indicated for your specific cable type.

  3. Prepare Cable Shield

    Prepare the cable shield based on its type: fold back shield wires, remove and tape flat metallic tape, remove and install tape retainer/marker for fabric tape, remove and install tape marker for longitudinally corrugated shield, or remove semi-con shield and install tape marker. Do not cut or nick cable insulation. Refer to 10TL instructions for UNISHIELD* or lead sheath cable if applicable.

  4. Bevel Insulation and Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor and Crimp Lug

    Remove protruding cable insulation even with the end of the cable adapter, ensuring not to cut or nick the cable adapter or the conductor. Verify the exposed conductor length is 4 3/8”–4 11/16” (111mm–119mm); if not, redo the assembly. For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Verify the 'Check Dimension' before crimping is less than 6 1/2” (165mm). Crimp the compression lug following the supplied instructions. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter is 6 1/2”–7 1/4” (165mm–184mm) after crimping; if not, redo the assembly.

  6. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Make sure the cable adapter is still flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Connect Elbow to Mating Product

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean. Push the elbow onto the mating part. Using the 600 ATM assembly tool, thread the connector into the mating part until it bottoms. Apply 50 to 60 foot-pounds torque.

  8. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, avoiding damage to the eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded according to the instructions supplied with the grounding device, or through an alternate method if no grounding device is used. Waterproof the cable jacket at this point to prevent moisture from entering the cable.

  9. Install Mating Connector (Optional)

    If applicable, clean and lubricate the entire male interface and either a DR(G), GLR, or LR of the appropriate voltage class with the supplied or ELASTIMOLDr approved lubricant. Install the DR(G), GLR, or LR to the bushing interface following their respective supplied instructions.

  10. Perform Voltage Test (K656CCP Only)

    For K656CCP only, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer’s directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.