Authorized ABB Distributor (Installation Products)
ABB - Installation Products K650BIP-20 PACK - 15/25kV 600 Series Deadbreak Insulated Plug (with Cap). Material Epoxy, Length 4.5 inch, Widest Diameter 3 inch. - Pack of 20

ABB Installation Products K650BIP-20 PACK 15/25kV 600 Series Deadbreak Insulated Plug (with Cap). Material Epoxy, Length 4.5 inch…

UPC: 783786348077


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB K650BIP-20 Pack includes 20 units of 600 Series 15/25kV Deadbreak Insulated Plug with Cap for medium-voltage cable terminations. Each plug measures 4.5" in length with a 3" diameter, constructed from durable epoxy for reliable insulation and mechanical protection in underground and overhead systems. Rated for 15/25kV applications, these plugs suit utility, industrial, and commercial power distribution. The integrated cap protects against moisture, contaminants, and physical damage. Epoxy construction provides high dielectric strength and environmental stress resistance for long-term performance. Compatible with standard 600A deadbreak bushings and connectors, they ensure secure insulated cable terminations. Commonly used in pad-mounted transformers, switchgear, and junction enclosures. The 20-unit pack supports maintenance, upgrades, or new installations, reducing downtime and costs. Manufactured by ABB’s Installation Products division to meet medium-voltage industry standards, ensuring safety and performance compliance. Compact design suits confined spaces and high-density installations.
  • Rated for 15/25kV medium-voltage applications
  • Epoxy construction for high dielectric strength and environmental resistance
  • 4.5" length, 3" widest diameter for compact installations
  • Includes protective cap for moisture and contaminant resistance
  • Pack of 20 units for maintenance, upgrades, or new installations

Specifications

Application
15/25 kV, 600 Amps
Material
Epoxy
Series
600 Series
Size
Length 4.5 inch, Widest Diameter 3 inch
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Insulated Plug with Cap
Voltage Rating
15/25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.5800 L
Package Weight (Metric)
0.7170 kg
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.

K675TBC

15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
Sealing Cap, Black, Thermoplastic, AMP CPC

208652-1

Sealing Cap, Black, Thermoplastic, AMP CPC
Elbow Tap Plug, 200 Amp Load Break 25kv, White Silicone Band

K650ETP-WB

Elbow Tap Plug, 200 Amp Load Break 25kv, White Silicone Band
15/25kV 600 Series Deadbreak Reducing Tap Well, 600/200 Amps. 20 pack.

K650RTW-20 PACK

15/25kV 600 Series Deadbreak Reducing Tap Well, 600/200 Amps. 20 pack.
15/25kV, 900 Amp, Deadbreak, Insulating Plug with Cap, with Loose Stud.

K675BIPS

15/25kV, 900 Amp, Deadbreak, Insulating Plug with Cap, with Loose Stud.
600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. Pack of 15.

K650CP-15 PACK

600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. Pack of 15.
15/25kV, 900Amp, Deadbreak, Stick-Op Bushing Adapter.

K675BEA2

15/25kV, 900Amp, Deadbreak, Stick-Op Bushing Adapter.
15/25kV 600 Series Deadbreak Reducing Tap Plug, 600/200 Amps. 15 pack.

K650RTP-15 PACK

15/25kV 600 Series Deadbreak Reducing Tap Plug, 600/200 Amps. 15 pack.

Frequently Asked Questions

What connectors are compatible with the K650BIP insulating plug?

The K650BIP insulating plug attaches and insulates Elastimold® K655/6BLR, K655BE, and K655BVS 600 A connectors.

What is the maximum operating voltage for the 28kV class K650BIP?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.

What items are included in the K650BIP insulating plug kit?

Each K650BIP kit contains one insulating plug with cap, one tube of lubricant (82-08), and one installation instruction (IS-0230).

How is the K650BIP insulating plug connected or disconnected?

The K650BIP can be easily connected or disconnected using standard hand tools and equipment when in a de-energized state.

What is the BIL impulse withstand rating for the 28kV class K650BIP?

For the 28kV voltage class, the BIL impulse withstand rating is 140kV (1.2 x 50 microsecond wave).

What is the maximum phase-to-phase voltage for the 28kV class?

The maximum phase-to-phase voltage for the 28kV voltage class is 28kV.

What is the momentary current rating for the K650BIP?

The K650BIP has a momentary current rating of 25kA symmetrical for 10 cycles, applicable to both voltage classes.

What is the continuous current rating of the K650BIP?

The K650BIP has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.

What is the BIL impulse withstand rating for the 15kV class K650BIP?

For the 15kV voltage class, the BIL impulse withstand rating is 95kV (1.2 x 50 microsecond wave).

What is the maximum phase-to-phase voltage for the 15kV class?

The maximum phase-to-phase voltage for the 15kV voltage class is 14.4kV.

How to Install the Link-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for installing the Link-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and connection procedures for 15kV and 25kV applications. Ensure all apparatus are de-energized before starting.

Estimated time: 2h

Tools needed:

Hot stick, Torque wrench, 600ATM (600 Ampere Torque/Operating Tool), Wire strippers, Multimeter (for testing de-energized status), Suitable tool for 1 inch hex portion

Supplies needed:

ELASTIMOLD supplied lubricant, Hex nuts, Lockwashers, 3/8-16 x 2 inch long studs (if applicable), Spacers (optional, not supplied), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connectors, Hardware supplied with alignment bracket

  1. Prepare for Installation and Ensure Safety

    WARNING: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure the elbow is positioned such that it will align correctly with the stand-off plug.

  3. Mount the Stand-Off Plug (If Applicable)

    If using a mounted stand-off plug, weld three 3/8-16 x 2 inch studs to the faceplate according to specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Install the stand-off plug over the studs, resting on the nuts or spacers. Secure with lockwashers and hex nuts, tightening to 12 foot-lbs torque. Verify the top surfaces of the bushing and stand-off plug are in-line; readjust nuts if necessary.

  4. Install Bushing Extender and Elbow onto Apparatus

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool applied to the 1 inch hex portion of the 600ATM, torquing to 50-60 ft-lbs. Repeat the cleaning, lubricating, and installation process for the epoxy standoff plug and the 600 amp elbow.

  5. Install and Secure the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.

  6. Position and Secure the Elbow in the Bracket

    Position the elbow in the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert and Engage the Link

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted. Insert the Link into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye to engage the roller pin and move the Link inward. Continue until the lever arms are perpendicular to the alignment bracket leg.

  8. Complete Grounding Connections

    Ground the elbow: Feed a #14 AWG or #12 AWG solid copper wire through the grounding eye on the elbow, twist it tight, and connect it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface according to its specific installation instructions. Ground the cable: If using concentric neutral cable, twist the concentric neutral wires together and connect to ground using an appropriate connector. If using 20MA or 21MA grounding devices, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.

  9. Refer to Operating Instructions

    For proper operation of the Link and any 200 ampere mating products, refer to their respective applicable operating instructions. This completes the physical installation and initial setup.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.