ABB Installation Products K650RTW-20 PACK 15/25kV 600 Series Deadbreak Reducing Tap Well, 600/200 Amps. 20 pack.
UPC: 783786348084
Contact for Pricing
Minimum Qty: 20
Multiplier: 20
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV Voltage Rating for medium voltage applications
- 600 Amp main line current capacity
- 200 Amp tap line current capacity
- Deadbreak design for safe connections
- 20-pack for project efficiency
Specifications
Application | 15/25 kV, 600 Amps |
Current Rating | 600/200 A |
Series | 600 Series |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Reducing Tap Well |
Voltage Rating | 15/25kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.6600 L |
Package Weight (Metric) | 0.7530 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.Frequently Asked Questions
What is the K650RTW Reducing Tap Well used for?
The K650RTW permits a 200A deadbreak or loadbreak tap-off from a 600A connector. It is a 15/25kV, 600 Amp Deadbreak Reducing Tap Well.
What are the operating voltage limits for 28kV class?
For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV and the maximum phase-to-phase is 28kV.
What is the AC one-minute withstand for 28kV?
For the 28kV voltage class, the AC one-minute withstand is 45kV.
What is the AC one-minute withstand for 15kV?
For the 15kV voltage class, the AC one-minute withstand is 34kV.
How do I order the 15/25kV 600A reducing tap well?
To order the 15/25kV, 600A reducing tap well, specify the ordering number K650RTW.
What items are included in the K650RTW kit?
Each kit contains one K650RTW Reducing Tap Well, one tube of lubricant 82-08, and one Installation Instruction IS-0230.
What is the impulse withstand rating for the 28kV class?
For the 28kV voltage class, the impulse withstand (BIL) is 140kV (1.2 x 50 microsecond wave).
What is the impulse withstand rating for the 15kV class?
For the 15kV voltage class, the impulse withstand (BIL) is 95kV (1.2 x 50 microsecond wave).
What is the continuous current rating of the K650RTW?
The K650RTW has a continuous current rating of 600 Amps for both 15kV and 28kV voltage classes.
What are the operating voltage limits for 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
How to Install 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products
This guide provides step-by-step instructions for the safe installation and voltage testing of 15/25/35kV 600/900 AMP Deadbreak Plug and Well Products, including mating with elbows or bushing extensions. Always ensure apparatus is de-energized before beginning.
Estimated time: 1h
Tools needed:
Torque wrench, ELASTIMOLD® 600SW spanner wrench, Hotstick, Suitable sensing device for capacitive test points
Supplies needed:
15/25/35kV 600/900 AMP Deadbreak Plug or Well, Lubricant (supplied, DO NOT SUBSTITUTE), Elbow or Bushing Extension (mating part), Stud (if not equipped on mating interface), HV insulated cap(s) or connector(s), Voltage detection cap (if insulating plug is used), Silicone lubricant
- De-energize and Inspect Components
Before beginning, ensure all apparatus is de-energized. Do not touch or move energized products in the work area. Verify the package contents are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products, and check for any damage or excessive distortion. If the product came with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing the circuit.
- Prepare and Lubricate Components
Remove any protective caps from the plug or well product. If the 600 amp mating interface on the plug or well is not equipped with a stud, hand tighten the supplied stud into the 600 amp interface. Lubricate both the elbow (or bushing extension) and its mating part using only the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Ensure all surfaces of the elbow and mating parts remain clean.
- Connect Plug/Well to Mating Part
Carefully push the plug or well into the elbow or bushing extension, ensuring the threads engage properly.
- Secure Connection with Torque Wrench
For an insulating plug, use a torque wrench and tighten the connection to 50 to 60 foot-pounds of torque. For a connector plug, tap plug, or tap well, use a torque wrench with an ELASTIMOLD® 600SW spanner wrench and tighten to an indicated torque of 40 to 48 foot-pounds. (Note: For K651 and 750 Rubber Connecting Plugs, refer to special instructions IS-0915, which are not included here).
- Install Voltage Detection Cap
If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down hard until it snaps into place. Proceed to the voltage test directions.
- Perform Voltage Test
The ELASTIMOLD® deadbreak elbow connector features an integral capacitance test point to determine if the circuit is energized. First, remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for separable connectors with capacitive test points, following the manufacturer’s directions for the meter. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means, as contamination, moisture, dirt, or incorrect equipment can cause false readings. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.