ABB - Installation Products K650J3U - 15/25kV 600 Series Deadbreak 3-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.

ABB Installation Products K650J3U 15/25kV 600 Series Deadbreak 3-Point Junction, Rubber Junction with stainless steel…

UPC: 783786328277


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K650J3U 15/25kV 600A Deadbreak 3-Point Junction is a medium-voltage cable accessory engineered for reliable electrical connections in utility and industrial power distribution systems. This deadbreak junction features a fully shielded, fully submersible molded rubber housing constructed from 100% peroxide-cured EPDM materials, ensuring long-term insulation integrity and environmental protection for underground or overhead cable splices. The 3-point design provides secure insulation and corrosion resistance in harsh or corrosive environments. The K650J3U includes a stainless steel mounting plate, back plate, and adjustable mounting bracket for flexible installation on flat surfaces in subsurface, vault, or padmount applications. Rated for 15/25kV systems with a continuous current rating of 600A, this junction meets ANSI/IEEE Standard 386 for medium-voltage cable accessories. Key electrical ratings include 8.3kV max phase-to-ground and 14.4kV max phase-to-phase operating voltage for 15kV class, with 16.2kV max phase-to-ground and 28kV max phase-to-phase for 25kV class. Designed to mate with Elastimold® 600A Series Elbow connectors, the K650J3U supports applications including sectionalizing, looping, tapping, and equipment bypass. Typical installations include utility substations, wind farms, solar installations, and commercial/industrial power distribution networks where durable, maintenance-free cable junctions are required. The deadbreak design enables safe, load-break connections without service interruption, making it ideal for maintenance, upgrades, or emergency repairs. Each kit includes the molded junction, mounting hardware, lubricant tubes, installation instructions, and protective caps for complete installation readiness.
  • 15/25kV rated, 600A continuous current capacity
  • Fully shielded, submersible molded rubber housing with peroxide-cured EPDM construction
  • Stainless steel mounting plate, back plate, and adjustable bracket for corrosion resistance
  • Meets ANSI/IEEE Standard 386 with 95kV BIL (15kV) and 140kV BIL (25kV) impulse ratings
  • Compatible with Elastimold® 600A Series Elbow connectors for sectionalizing and tapping applications

Specifications

Application
Designed for subsurface, vault or padmount applications and can be used for sectionalizing, looping, tapping, and equipment bypass
Connection
Push-In
Connection Type
Deadbreak
Material
EPDM-Rubber
Material
Rubber, Stainless Steel
Material
Rubber
Mounting Type
Stainless Steel Mounting Plate, Back Plate, Adjustable Mounting Bracket
Mounting Type
Stainless Steel Mounting Plate with Adjustable Bracket
Poles
3-point
Poles
3
Series
600 Series
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provides mating for Elastimold 600 Amp Series Elbow connectors. Stainless Steel Mounting Plate, Back Plate and Adjustable Mounting Bracket
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
3-Point Rubber Junction
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
14.5000 L
Package Weight (Metric)
6.5770 kg
6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.

J6-622226-25

6 Point Junction, with one 600 Amp Bushing Interfaces, four 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
200 Amp, 15kV, Double parking stand bushing

164BSOP

200 Amp, 15kV, Double parking stand bushing
15/25kV 600 Series Deadbreak 4-Point Junction, Rubber Junction only.

K650-J4-4

15/25kV 600 Series Deadbreak 4-Point Junction, Rubber Junction only.
15/25kV 600 Series Deadbreak 2-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.

K650-J2-U

15/25kV 600 Series Deadbreak 2-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.
15/25kV 600 Series Deadbreak 2-Point Junction, Rubber Junction only.

K650-J2-4

15/25kV 600 Series Deadbreak 2-Point Junction, Rubber Junction only.
Junction, 2pt, 600 Amp Dead Break , 15/25kv With bracket

K650J2SP

Junction, 2pt, 600 Amp Dead Break , 15/25kv With bracket
15/25kV 600 Series Deadbreak 4-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.

K650-J4-U

15/25kV 600 Series Deadbreak 4-Point Junction, Rubber Junction with stainless steel mounting plate, back plate and adjustable mounting bracket.
15/25kV 600 Series Deadbreak 3-Point Junction, Rubber Junction, Stainless Steel U-Straps and Back Plate.

K650-J3-5

15/25kV 600 Series Deadbreak 3-Point Junction, Rubber Junction, Stainless Steel U-Straps and Back Plate.

Frequently Asked Questions

What are the voltage and current ratings of the K650J3?

The K650J3 is a 3-way deadbreak junction rated for 15/28kV and 600 Amp continuous current.

What is the BIL impulse withstand for the 15kV class?

For the 15kV voltage class, the BIL impulse withstand is 95kV (1.2 x 50 microsecond wave).

What is the momentary current rating of the K650J3?

The K650J3 has a momentary current rating of 25kA Symmetrical for 10 cycles.

What is the AC and DC withstand voltage for the 28kV class?

For the 28kV voltage class, the one-minute AC withstand is 45kV, and the 15-minute DC withstand is 84kV.

What is the BIL impulse withstand for the 28kV class?

For the 28kV voltage class, the BIL impulse withstand is 140kV (1.2 x 50 microsecond wave).

What is the maximum operating voltage for the 28kV class?

For the 28kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV, and phase-to-phase is 28kV.

What is the AC and DC withstand voltage for the 15kV class?

For the 15kV voltage class, the one-minute AC withstand is 34kV, and the 15-minute DC withstand is 53kV.

What is the maximum operating voltage for the 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV, and phase-to-phase is 14.4kV.

What standard does the K650J3 junction meet?

The K650J3 junction meets ANSI/IEEE Standard 386, Latest Revision.

How is the K650J3 junction mounted?

The K650J3 junction is equipped with a stainless steel mounting bracket and back plate suitable for mounting on a flat surface.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for installing the LINK-C 600 amp deadbreak cam link operable connector system, including mounting the stand-off plug, installing the bushing extender and elbow, and connecting the link to ensure a fully shielded and submersible connection.

Estimated time: 2h

Tools needed:

Hot stick, Torque wrench, 600ATM Operating Tool, Wire strippers, Welding equipment (if studs are not pre-welded), Suitable tool for 1 inch hex

Supplies needed:

ELASTIMOLD supplied lubricant, 3/8-16 hex nuts (6), Lockwashers (3), 3/8-16 x 2 inch studs (3, if welding), #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, Hardware supplied with alignment bracket, 600 amp elbow, Desired 200 amp mating product

  1. Prepare for Installation and Ensure Safety

    DANGER: Before beginning, ensure all apparatus is de-energized. Inspect all package contents for completeness and damage, and verify component compatibility and proper fit with the cable and mating products. Have all required tools readily available and maintain a clean work area throughout the procedure. This product should only be installed by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the specific installation instructions provided with the elbow. Ensure the elbow is positioned to align correctly with the stand-off plug.

  3. Mount the Stand-Off Plug

    If not already present, weld three 3/8-16 x 2 inch studs to the equipment faceplate according to the specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the apparatus bushing. Place the stand-off plug over the studs, resting on the nuts or optional spacers. Secure the stand-off plug by installing a lockwasher and hex nut on each stud, then tighten all three hex nuts to 12 foot-lbs torque. Verify that the top surfaces of the bushing and stand-off plug are in-line, adjusting the nuts as needed.

  4. Install the Bushing Extender and Elbow

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage its internal hex broach, and thread the retainer contact into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM. Torque to 50-60 ft-lbs. Next, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact, engage its internal hex broach, and thread the retainer contact into the epoxy standoff plug through the compression lug hole. Torque to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender, measuring 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket using the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.

  6. Secure the Elbow in the Alignment Bracket

    Carefully position the elbow within the alignment bracket, ensuring the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket using the supplied hardware. Torque by alternating sides until the clamp tabs are flush and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Install the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD supplied lubricant. Align the LINK-C connector so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the LINK-C connector into both the bushing extender and elbow, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. Using a hot stick on the hot stick eye, push inward and move the lever arms downward to engage the roller pin and move the LINK-C connector inward. Continue until the lever arms are perpendicular to the alignment bracket leg.

  8. Ground the System and Install Mating Products

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through its grounding eye, twisting it tight, and connecting it to a common ground point. Clean and lubricate the 200 amp interface on the LINK-C connector. Ground and then install the desired mating product onto the 200 amp interface, following its specific installation instructions. Ensure the cable is also properly grounded; if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector. For three-phase installations, tie all grounds from all three phases to a common ground point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.