ABB Installation Products K650CP-15 PACK 600 Amp, 15/25kV, Deadbreak, Connecting Plug. Widest Diameter 3 inches. Pack of 15.
UPC: 783786348107
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV 600A Deadbreak rated for safe de-energized connections
- 3-inch diameter for compatibility with standard busbar systems
- Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand
- 100% peroxide-cured EPDM construction for durability
- Available with or without stud; includes lubricant and instructions
Specifications
Application | 15/25 kV, 600 Amps |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Connecting Plug |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.6700 L |
Package Weight (Metric) | 1.2110 kg |

150-TB-2
15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.
K655LINKCLRL0270BDRG
600 Amp, 25kV, Deadbreak, Cam-Op Connector Kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap.
K655YASR-H0270-S
600 Amp, 15/25KV, Straight Receptacle, cable Insulation Diameter 0.850 - 1.050 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 4/0 AWG or Compact Solid 250 kcmil. Includes Cold-Shrinkable Jacket Seal.
K676DRGSP
600 Amp, 15/25kV, Insulated Cap with Test Point, with Ground, with Factory Assembled Stud which is not field removable.Frequently Asked Questions
What is the current rating of this ABB connecting plug?
The ABB K650CP-15 PACK connecting plugs have a current rating of 600 Amps.
What is the voltage rating for these deadbreak connectors?
These deadbreak connectors are rated for 15/25kV.
What is the widest diameter of the ABB connecting plugs?
The widest diameter of these ABB connecting plugs is 3 inches.
How many connecting plugs are included in the K650CP-15 PACK?
The K650CP-15 PACK includes fifteen (15) connecting plugs.
What type of connection does this ABB product provide?
This ABB product provides a deadbreak connection.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe installation and initial setup of the LINK-C Deadbreak Cam Link Operable Connector System, including mounting, wiring, and grounding procedures for the alignment bracket configuration.
Estimated time: 2h
Tools needed:
Torque wrench with 1 inch hex socket, Hot stick, Wire strippers
Supplies needed:
ELASTIMOLD supplied lubricant, No. 14 AWG or No. 12 AWG solid copper wire, Appropriate grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)
- Perform Initial Safety Checks and Preparation
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, proper rating, and compatibility with mating parts. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Install the 600 Amp Elbow onto the Cable
Install the 600 amp elbow onto the cable according to the installation instructions supplied with the elbow. Ensure it is positioned to align with the standoff plug.
- Prepare and Install the Bushing Extender
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool applied to the 1 inch hex portion of the 600ATM. Torque to 50-60 ft-lbs.
- Prepare and Install the 600 Amp Elbow onto the Epoxy Standoff Plug
Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Install the elbow onto the epoxy standoff plug. Insert the 600AMT into the retainer contact through the hole in the compression lug, engage the internal hex broach, and thread into the epoxy standoff plug using a suitable tool applied to the 1 inch hex portion of the 600AMT. Torque to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware and torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. Position the elbow in the alignment bracket such that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware and torque by alternating sides until the clamp tabs are flush with each other and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Insert and Secure the Link
Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, engaging the roller pin and moving the Link inward. Continue moving lever arms until perpendicular to the alignment bracket leg.
- Ground the System and Install Mating Products
Ground the elbow by feeding a No. 14 AWG or No. 12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground, then install the desired mating product on the 200 amp interface according to its specific installation instructions. Ground the cable: if concentric neutral cable is used, twist the concentric neutral wires together and connect to ground using an appropriate connector; if 20MA or 21MA grounding devices are used, connect the ground lead from the device to ground using a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.